3. Disassembly and Reassembly
3.3.15. Feed and Regi sensor PBA
1. Remove the duplex unit. (Refer to 3.3.11)
4. Remove the sensor PBA after unplugging the harness.
2. Remove 1 screw.
3. Remove the sensor cover while pushing the hook.
Copyright© 1995-2017 SAMSUNG. All rights reserved.
3-17