Advertisement

Quick Links

S-II & J-II Chairs
Operating / Service
Manual
IMPORTANT: Read all instructions before assembling or using this device.
An Employee-Owned Company

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the S-II and is the answer not in the manual?

Questions and answers

Summary of Contents for Jedmed S-II

  • Page 1 S-II & J-II Chairs Operating / Service Manual IMPORTANT: Read all instructions before assembling or using this device. An Employee-Owned Company...
  • Page 2 S-II & J-II Chairs Operating / Service Manual JEDMED Instrument Company has been in business since 1978 and is entirely employee-owned (ESOP). Our goal is to provide the best overall equipment to the medical disciplines we serve. Thank you for your support and we hope that your experience with this product will be a rewarding one which will result in a lasting relationship with JEDMED.
  • Page 3: Table Of Contents

    S-II & J-II Chairs Operating / Service Manual CONTENTS Section Page OPERATING OPERATION Precautions Key.........4 Description..........5 Unpacking / Assembly......6 - 7 Identification / Operation.......8-13 Cleaning / Disinfection......14 Maintenance..........15 Dimensions........16 - 17 Reorder Items..........18 Specifications..........19 SERVICE Troubleshooting........24 Parts Diagrams....back of manual Service Procedures.....back of manual...
  • Page 4: Precautions Key

    S-II & J-II Chairs Operating / Service Manual PRECAUTIONS KEY The following conventions are used throughout this manual: WARNING ALERTS user to the possibility of PERSONAL INJURY.  CAUTION ALERTS user to the possibility of DAMAGE to the EQUIPMENT.  NOTE ALERTS user to PERTINENT FACTS or CONDITIONS.
  • Page 5: Description

    S-II & J-II Chairs Operating / Service Manual DESCRIPTION JEDMED S-II & J-II ENT Chairs offer flexibility and performance and were designed specifically with the otolaryngic specialist in mind. For routine examination and minor treatment in the office, these chairs are unsurpassed for integrating features, cost, and quality.
  • Page 6: Unpacking / Assembly

    Typically, chair is shipped blanket-wrapped and set up by the shipping crew.  CAUTION Use care not to cut upholstery or scratch chair with sharp tools.  NOTE Any shipping damage should be documented and reported immediately to the carrier or JEDMED.
  • Page 7 S-II & J-II Chairs Operating / Service Manual ASSEMBLY INSTRUCTIONS ASSEMBLY: Typically, all chairs arrive fully assembled. No on-site assembly is required other than mounting base to the floor. WARNING All lift bases must be bolted to floor to protect against accidental tipping.
  • Page 8: Identification / Operation

    S-II & J-II Chairs Operating / Service Manual IDENTIFICATION / OPERATION Main Parts Headrest Backrest Armrest Seat Footrest Lift base J-II Chair S-II Chair Chair Controls Headrest height adjustment handwheel Headrest tilt adjustment lever Recline lever Rear View Recline Lever on both sides of seat...
  • Page 9 S-II & J-II Chairs Operating / Service Manual IDENTIFICATION / OPERATION 1. Headrest Height Adjustment *Unlock position by rotating handwheel counter-clockwise. *Raise or lower headrest to new desired position. *Lock position by rotating handwheel firmly clockwise.  CAUTION Do not tighten handwheel if 2.
  • Page 10 S-II & J-II Chairs Operating / Service Manual IDENTIFICATION / OPERATION Lift Base Controls (Electric Base) "Up" pedal "Down" pedal Rotation lock (lift both pedals) Floor mounting holes Electric Lift Base WARNING All lift bases must be bolted to floor to protect against accidental tipping of chair.
  • Page 11 S-II & J-II Chairs Operating / Service Manual IDENTIFICATION / OPERATION Electric Lift Base Operation *Raise base by depressing "Up" pedal. *Lower base by depressing "Down" pedal. *Lock chair rotation by firmly lifting with top of foot on both pedals simultaneously.
  • Page 12 S-II & J-II Chairs Operating / Service Manual IDENTIFICATION / OPERATION OPTIONS Examination Light Exam Light Kit Light Installed Pediatric Booster Seat Booster In Place Headrests Standard Headrest Double-articulating Headrest...
  • Page 13 S-II & J-II Chairs Operating / Service Manual Blank...
  • Page 14: Cleaning / Disinfection

    S-II & J-II Chairs Operating / Service Manual CLEANING & DISINFECTING WARNING ALWAYS unplug unit from main power outlet before cleaning, disinfecting, maintenance, or service. Cleaning Chairs and bases may be wiped clean using a soft cloth moistened with water and a mild detergent.
  • Page 15: Maintenance

    S-II & J-II Chairs Operating / Service Manual MAINTENANCE WARNING Grounding continuity should be checked periodically to insure patient and user safety. Scheduled Maintenance All chairs (motorized and manual) should be cycled fully up and down 8-10 times every 60 days. Even if chair is used regularly, often the working height is within a limited range.
  • Page 16: Dimensions

    S-II & J-II Chairs Operating / Service Manual 41.50" DIMENSIONS 20.00" to 28.00" S-II Chair 23.00 " 32.00" 41.50" 20.25 " 20.00" 20.00" to 28.00" 8.75" to 23.50 " 21.50 " 13.00 " 9.50 " 13.00" 23.00 " 76.25 " to 80.50"...
  • Page 17 S-II & J-II Chairs Operating / Service Manual DIMENSIONS J-II Chair Reclined Position (J-II) 04-1550 JEDMED J-II Chair with Manual Pump Base A=19.5” to 27” B=26.75” C=41.25” 41.25" 04-1555 JEDMED J-II Chair with Motorized Lift Base, 110V 19.50" to 27.00"...
  • Page 18: Reorder Items

    Bulb (for exam light)  NOTE For additional replacement parts refer to the “Exploded View” drawings in this manual or call JEDMED. Contact Information To order consumable or replacement parts contact your Regional Sales Representative or JEDMED Customer Service at: 5416 JEDMED Court St.
  • Page 19: Specifications

    S-II & J-II Chairs Operating / Service Manual SPECIFICATIONS Motorized Hydraulic Base Volts Max. Frequency Power Item # (Vac) (Amps) (Hz) Input Notes 04-1332 50/60 0.2kW Standard 04-1333 50/60 0.2kW Special Order 50/60 0.2kW Special Order Lifting Capacity 350 lbs...
  • Page 20 S-II & J-II Chairs Operating / Service Manual Blank...
  • Page 21: Service

    SERVICE INFORMATION...
  • Page 22 Blank...
  • Page 23 S-II & J-II Chairs Operating / Service Manual SERVICE INFORMATION Service should only be performed by a qualified technician. Contact JEDMED for further information. WARNING ALWAYS unplug unit from main power outlet before cleaning, disinfecting, maintenance, or service.
  • Page 24: Troubleshooting

    S-II & J-II Chairs Operating / Service Manual TROUBLESHOOTING Problem Possible Cause Solution Test power outlet with another device Chair base is not plugged into a Chair will not lift at all (electric base). to assure power is available. powered outlet.
  • Page 25 04-1332 LIFT BASE: ELECTRIC, 115V K117038 MS: M4 X 16MM, OVAL HD, PH, SS KA08018 502-004 HEADREST CUSHION F/ S-II, J-II & L (SPECIFY COLOR) K905004 HEADREST BRACKET K117037 CS: M8 X 25MM, HX HD, BLUE K117031 CS: M8 X 20.0MM, SERRATED FLANGE, HX, Z K117034 CS: M8 X 40.0MM, SERRATED FLANGE, HX, Z...
  • Page 26 04-1332 LIFT BASE: ELECTRIC, 115V K117038 MS: M4 X 16MM, OVAL HD, PH, SS KA08018 502-004 HEADREST CUSHION F/ S-II, J-II & L (SPECIFY COLOR) K905004 HEADREST BRACKET K117037 CS: M8 X 25MM, HX HD, BLUE K117031 CS: M8 X 20.0MM, SERRATED FLANGE, HX, Z K117034 CS: M8 X 40.0MM, SERRATED FLANGE, HX, Z...
  • Page 27: Parts Diagrams

    S-II & J-II Chairs Operating / Service Manual SERVICE INFORMATION Parts Diagram Motorized Lift Base (115V & 230V) Part # Description Part # Description Pump Cover (black) not shown Control Lever (right) Rubber Plug (black) Control Lever (left) Capacitor (condenser)*...
  • Page 28 S-II & J-II Chairs Operating / Service Manual SERVICE INFORMATION Parts Diagram Manual Lift Base Taper Lock Nut HLP - 5547 Lock HLP -4042 Lock Retaining Screw HLP - 5548 Quad Ring HLP - 5512 Cam Screw HLP - 5546...
  • Page 29 NOTES...
  • Page 30 5416 JEDMED Court St. Louis, MO 63129 (314) 845-3770 phone (314) 845-3771 fax e-mail: info@jedmed.com website: www.JEDMED.com...

This manual is also suitable for:

J-ii

Table of Contents