Advertisement

2500447
Please read all instructions carefully before use and
retain for future reference.
Disconnect appliance from mains before cleaning,
maintenance or after a thermal cut out event.
Do not cover.
CAUTION Do not immerse in water.
Do not use outdoors.
A5P | 01
Caution Risk of fire R290
INTENDED USE.
This Dehumidifier is for indoor domestic use only. Do not
use outdoors or on wet surfaces.
This appliance is not intended for use by persons
(including children) with reduced physical, sensory
or mental capabilities, or lack of experience and
knowledge, unless they have been given supervision or
instruction concerning use of the appliance by a person
responsible for their safety.
GENERAL PRECAUTIONS.
When using an electrical appliance, basic precautions
should always be followed, including the following:
Do not allow to be used as a toy. Close attention is
necessary when used near children. Children should
be supervised to ensure that they do not play with the
appliance.
If the appliance is not functioning properly, has been
dropped, damaged, left outdoors, or immersed in liquid,
do not use, contact DOMU Brands Customer Services.
Do not use the appliance if any parts appear to be faulty,
missing or damaged.
Ensure all parts are securely attached before using the
appliance.
CABLES AND PLUGS.
Check to ensure your electricity supply matches that
shown on the rating plate. The appliance must only be
used as rated.
Ensure the unit is disconnected from the main outlet
before cleaning.
The use of an extension cable is not recommended.
Do not let cord hang over the edge of the table or
counter-top where it could be pulled on inadvertently
by children or pets, or touch hot surfaces which could
damage the cord.
Do not pull the cable around sharp edges or corners.
Keep the cord away from heated surfaces.
Turn off all controls before unplugging.
Do not unplug by pulling on cable. To unplug, grasp the
adaptor, not the cable.
Ensure the cable is stored safely to prevent hazards.
The appliance shall be installed in accordance with
local/national wire regulations.
If the supply cable is damaged, it must be replaced by a
qualified engineer in order to avoid a hazard.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 2500447 and is the answer not in the manual?

Questions and answers

Summary of Contents for VonHaus 2500447

  • Page 1 2500447 Please read all instructions carefully before use and retain for future reference. Caution Risk of fire R290 Disconnect appliance from mains before cleaning, maintenance or after a thermal cut out event. INTENDED USE. This Dehumidifier is for indoor domestic use only. Do not use outdoors or on wet surfaces.
  • Page 2: Technical Specification

    RISK OF PERSONAL INJURY. grills. Always locate your appliance away from the edge of For maximum performance ensure the minimum any worktop, on a firm, flat, heat-resistant surface with distance from walls or objects is be 20cm to ensure air circulation.
  • Page 3 COMPONENTS 1. Control Panel 2. Mode Indicators 3. Carry Handle 4. Air Outlet 5. Air Inlet with Filter 6. Water Tank 7. Continuous Drainage hole 8. Overflow Pipe A5P | 01...
  • Page 4: Control Panel

    CONTROL PANEL POWER: : When the unit is powered on the indicators and LED will display for 1 second after a ‘‘buzz’’ is heard the power indicator will be in standby mode. Pressing the Power Button will start the unit in default mode the fan will start and the display will indicate the current room humidity.
  • Page 5: Lcd Panel

    LCD PANEL Fan is on Low Continuous Mode is active Sleep Button Lock is active Mode Fan is on High Tank is Full Automatic Mode On/Off indicator Timer is set Humidity / Current Humidity POSITIONING A poorly positioned Dehumidifier will have little effect and will not work to its potential.
  • Page 6 WATER TANK & WATER DISPOSAL When the Water Tank is full the Indicator will display and the unit will stop automatically. Unplug from the mains and remove the tank by holding the grips either side and pulling away. NOTE: Do not set the tank down as the base is uneven.
  • Page 7: Maintenance

    MAINTENANCE Clean debris from the filter using a soft bristle brush then with clean running water do not use any detergents or abrasive chemicals, rinse the filter thoroughly and leave to completely dry for 24 hours CAUTION: Do not operate the unit without the fil- ter in place and ensure it is completely dry before re-installing.
  • Page 8 MAINTENANCE 1.Checks to the area 6.Ventilated area Prior to beginning work on systems containing Ensure that the area is in the open or that it is ade- flammable refrigerants, safety checks are neces- quately ventilated before breaking into the system or sary to ensure that the risk of ignition is minimized conducting any hot wok.
  • Page 9: Refrigerant Charging Procedures

    MAINTENANCE to original specification, damage to seals, incorrect removed/extinguished. fitting of glands, etc. If a leak of refrigerant is found which requires braz- Ensure that apparatus is mounted securely. ing, all of the refrigerant shall be recovered from the Ensure that seals or sealing materials have not de- system.
  • Page 10 MAINTENANCE 16.Decommissioning shall be complete with pressure relief value and Before carrying out this procedure, it is essential that associated shut-off values in good working order. technician is completely familiar with the equipment Empty recovery cylinders are evacuated and, if and all its detail.
  • Page 11: Troubleshooting

    TROUBLESHOOTING Water Tank has not been fully inserted. No power to the unit Power Cord may be damaged. Contact Customer services. Ensure Water Tank is not full before use. Doors and windows may be open. Seal the room from external areas. Only small amounts of water being Water Tank has not been fully inserted.
  • Page 12 Thank you for purchasing your product/appliance. Should you require further assistance with your purchase, you can contact us at support@domu.co.uk VonHaus is a registered trademark of DOMU Brands Ltd. Made in China for DOMU Brands. M24 2RW. A5P | 01...

Table of Contents

Save PDF