User system interface cable (hs2218ecn61h) for e6000 emulator

Advertisement

Quick Links

IMPORTANT INFORMATION
• READ this user's manual before using this user system interface cable.
• KEEP the user's manual handy for future reference.
Do not attempt to use the user system interface cable until you fully understand its
mechanism.
User System Interface Cable:
Throughout this document, the term "user system interface cable" shall be defined as the
following product produced only by Renesas Technology Corp. excluding all subsidiary products.
• User system interface cable (HS2218ECN61H)
The user system or a host computer is not included in this definition.
Purpose of the User System Interface Cable:
This user system interface cable is for connecting the emulator station and user system. This
user system interface cable must only be used for the above purpose.
Improvement Policy:
Renesas Technology Corp. (including its subsidiaries, hereafter collectively referred to as
Renesas) pursues a policy of continuing improvement in design, performance, functions, and
safety of the user system interface cable. Renesas reserves the right to change, wholly or partially,
the specifications, design, user's manual, and other documentation at any time without notice.
Target User of the User System Interface Cable:
This user system interface cable should only be used by those who have carefully read and
thoroughly understood the information and restrictions contained in the user's manual. Do not
attempt to use the user system interface cable until you fully understand its mechanism.
It is highly recommended that first-time users be instructed by users that are well versed in the
operation of the user system interface cable.
READ FIRST
I

Advertisement

Table of Contents
loading

Summary of Contents for Renesas H8S/2218 Series

  • Page 1 Renesas) pursues a policy of continuing improvement in design, performance, functions, and safety of the user system interface cable. Renesas reserves the right to change, wholly or partially, the specifications, design, user's manual, and other documentation at any time without notice.
  • Page 2 User system interface cables are wearing parts which Renesas will not repair or replace if damaged and/or worn through use. The foregoing shall constitute the sole remedy for any breach of Renesas's warranty.
  • Page 3 This user's manual and user system interface cable are copyrighted and all rights are reserved by Renesas. No part of this user's manual, all or part, may be reproduced or duplicated in any form, in hard-copy or machine-readable form, by any means available without Renesas's prior written consent.
  • Page 4 SAFETY PAGE READ FIRST • READ this user's manual before using this user system interface cable. • KEEP the user's manual handy for future reference. Do not attempt to use the user system interface cable until you fully understand its mechanism.
  • Page 5 WARNING Observe the precautions listed below. Failure to do so will result in a FIRE HAZARD and will damage the user system and the emulator product or will result in PERSONAL INJURY. The USER PROGRAM will be LOST. 1. Do not repair or remodel the emulator product by yourself for electric shock prevention and quality assurance.
  • Page 6 H8S/2218 Series TFP-100G User System Interface Cable (HS2218ECN61H) for E6000 Emulator User’s Manual ADE-xxx-xxx Rev. 2.0 7/22/03 Renesas Technology Corp.
  • Page 7 Cautions 1. Renesas neither warrants nor grants licenses of any rights of Renesas’s or any third party’s patent, copyright, trademark, or other intellectual property rights for information contained in this document. Renesas bears no responsibility for problems that may arise with third party’s rights, including intellectual property rights, in connection with use of the information contained in this document.
  • Page 8 Preface Thank you for purchasing this user system interface cable (HS2218ECN61H) for the Renesas’s original microcomputer H8S/2218 series. The HS2218ECN61H is a user system interface cable that connects an H8S/2214 series E6000 emulator (HS2214EPI62H; hereinafter referred to as the emulator) to the IC socket for a TFP-100G package for the H8S/2218 series MCU on the user system.
  • Page 9: Table Of Contents

    Contents Section 1 Configuration..................1 Section 2 Connection Procedures ..............3 Connecting User System Interface Cable to Emulator Station ......... 3 Connecting User System Interface Cable to User System ..........5 2.2.1 Installing IC Socket ..................... 5 2.2.2 Soldering IC Socket ..................... 6 2.2.3 Inserting Cable Head ...................
  • Page 10: Section 1 Configuration

    Section 1 Configuration CAUTION Use an NQPACK100SE socket (manufactured by Tokyo Eletech Corporation) for the TFP-100G package IC socket on the user system. Figure 1 shows the configuration of the HS2218ECN61H user system interface cable for the TFP-100G package. To emulator station Screws (M3 x 6 mm) for fixing the cable body Cable body...
  • Page 11 Table 1 lists the HS2218ECN61H components. Please make sure you have all of these components when unpacking. Table 1 HS2218ECN61H Components No. Component Quantity Remarks Cable body Includes coaxial cable Cable head Consisting of two printed circuit boards IC socket For the TFP-100G package Socket cover For installing a TFP-100G packaged MCU...
  • Page 12: Section 2 Connection Procedures

    Section 2 Connection Procedures Connecting User System Interface Cable to Emulator Station WARNING Observe the precautions listed below. Failure to do so will result in a FIRE HAZARD and will damage the user system and the emulator product or will result in PERSONAL INJURY.
  • Page 13 Emulator station Cable body connector User system interface cable Screws for fixing the cable body Figure 2 Connecting User System Interface Cable to Emulator Station...
  • Page 14: Connecting User System Interface Cable To User System

    Connecting User System Interface Cable to User System WARNING Always switch OFF the user system and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from any part. Before connecting, make sure that pin 1 on both sides are correctly aligned.
  • Page 15: Soldering Ic Socket

    Guide pins 4 projections to apply IC socket epoxy resin adhesive to (NQPACK100SE manufactured by Tokyo Eletech Corporation) Pin 1 User system Bottom view of IC socket Figure 3 Location Setting of IC Socket 2.2.2 Soldering IC Socket After fastening, solder the IC socket for a TFP-100G package to the user system. Be sure to completely solder the leads so that the solder slops gently over the leads and forms solder fillets.
  • Page 16: Fastening Cable Head

    2.2.4 Fastening Cable Head CAUTION 1. Use a screwdriver whose head matches the screw head. 2. The tightening torque must be 0.054 N•m or less. If the applied torque cannot be accurately measured, stop tightening when the force required to turn the screw becomes significantly greater than that needed when first tightening.
  • Page 17 Screws (M2 x 10 mm) Cable head IC socket (NQPACK100SE Pin 1 manufactured by Tokyo Eletech Corporation) User system Figure 4 Connecting User System Interface Cable to User System...
  • Page 18: Fastening Cable Body

    2.2.5 Fastening Cable Body Connect the cable body to the cable head. Cable body Removing Push the remove jig Remove jig Cable head User system Figure 5 Fastening Cable Body...
  • Page 19: Recommended Dimensions For User System Mount Pad

    Recommended Dimensions for User System Mount Pad Figure 6 shows the recommended dimensions for the mount pad (footprint) for the user system with an IC socket for a TFP-100G package (NQPACK100SE: manufactured by Tokyo Eletech Corporation). Note that the dimensions in figure 6 are somewhat different from those of the actual chip's mount pad.
  • Page 20: Dimensions For User System Interface Cable Head

    Dimensions for User System Interface Cable Head The dimensions for the user system interface cable head are shown in figure 7. 21.0 21.3 63.5 Unit: mm Tolerance: ±0.5 mm Figure 7 Dimensions for User System Interface Cable Head...
  • Page 21: Resulting Dimensions After Connecting User System Interface Cable

    Resulting Dimensions after Connecting User System Interface Cable The resulting dimensions, after connecting the user system interface cable head to the user system, are shown in figure 8. Cable head Unit: mm IC socket Tolerance: ±0.5 mm User system (NQPACK100SE manufactured by Tokyo Eletech Corporation) Figure 8 Resulting Dimensions after Connecting User System Interface Cable...
  • Page 22: Section 3 Installing The Mcu To The User System

    Section 3 Installing the MCU to the User System CAUTION 1. Check the location of pin 1 before inserting. 2. Use a screwdriver whose head matches the screw head. 3. The tightening torque must be 0.054 N•m or less. If the applied torque cannot be accurately measured, stop tightening when the force required to turn the screw becomes significantly greater than that needed when first tightening.
  • Page 23 Screws (M2 x 6 mm) Socket cover IC socket (NQPACK100SE manufactured by Tokyo Eletech Corporation) Pin 1 User system Figure 9 Installing MCU to User System...
  • Page 24: Section 4 User Interface Circuit

    Section 4 User Interface Circuit The user system interface cable includes the H8S/2218 microcomputer to emulate the USB function. The H8S/2218 user interface signal includes a interface circuit as shown in figure 10. H8S/2218 HS2218ECN61H User system DrVcc DrVcc 0.1 µF 0.1 µF DrVss DrVss...
  • Page 25: Section 5 Verifying Operation

    Section 5 Verifying Operation 1. When using the H8S/2214 E6000 emulator for the H8S/2218 series, turn on the emulator according to the procedures described in the H8S/2214 E6000 Emulator User's Manual (HS2214EPI62HE). 2. Verify the user system interface cable connections by accessing the external memory and ports to check the bus states of the pins.
  • Page 26: Section 6 Notice

    Section 6 Notice 1. Make sure that pin 1 on the user system IC socket is correctly aligned with pin 1 on the cable head before inserting the cable head into the user system IC socket. 2. The dimensions of the recommended mount pad for the user system IC socket are different from those of the MCU.
  • Page 27 7. This emulator does not support mode 7 (single-chip mode). 8. In the H8S/2218 series, the USB control register and the RTC control register are allocated to external bus areas of area 6 (H’C00000 to H’DFFFFF) and area 7 (H’E00000 to H’FFFFFF), respectively.