Reviewing Sensor Data
After installing and configuring sensors, it is possible to
review sensor data as it is transmitted to the controller.
1. Press the
Diagnostic button.
2. Turn the Command dial
Menu: Sensor Monitor
Sensor Board Slot
P1: 150.7 R2: 00.12
S3: Open
R5: 00.14 I6: NONE
T7: 73
In the Sensor Monitor screen above:
• P1: a pressure sensor is installed on input 1
• R2: a rain bucket is installed on input 2
• S3: a status sensor is installed on input 3
• F4: a flow sensor is installed on input 4
• R5: a rain bucket is installed on input 5
• I6: input 6 does not have a sensor attached
• T7: input 7 has a temperature sensor attached
Units explained:
To see what units the numbers are in, press the down
arrow to get to the last line. The units of the numbers will
switch between an explanation of the metric and English
designations.
Designation
P
p
F
f
R
r
T
t
to Sensor Monitor.
8
F4: 33.10
PW: +12V
Unit
psi
kPa
gpm
lpm
inches
mm
Farenheit
Celcius
Clearing Alarms
The Home screen will display any current alarms with the
board and the terminal called out.
Mon 04/17/17 02:33pm
Sat# 001-001 Sec: 40
!ALARM! BRD 8 Sen 1
Day Change:
Lynx Smart Satellite
1. Press the
Diagnostic button.
2.
to Sensor Monitor.
3. Use the arrow keys to navigate to the desired input so
that it is highlighted.
4. Simply turn the Control Dial to clear the alarm.
Reset Sensor Settings
If it becomes necessary to reset all sensor settings:
1. Press the
Satellite Settings button.
2. Down arrow to Reset SIB's.
3.
to change to Yes All.
Hold Rain
Reset Prg's: No
Reset Sta's: No
Reset Unit : No
Reset SIB's:
Enabl Sta's: No
4. There is a confirmation screen.
Press the Stop button to cancel the reset.
Firmware Version
A handful of satellites will need a firmware update to take
advantage of the Lynx Smart Satellite Sensor Kit.
To check your satellite's firmware:
1. Press the
Diagnostic button.
2. Turn the Command dial
3. Check Revision number. If firmware revision is less
than 2.0, see your Toro distributor for a firmware
update.