2.3. Hydraulic installation

Security warning
It is always preferable that the pool is empty before installing the equipment.
However, if your pool is full and you do not wish to empty it, you should
carefully follow the instructions below:
1) Turn the filter selector valve to the "close"
position
2) Close the supply valves and, if available, the
return valves as well.
3) Disconnect the power supply in the area
where the equipment is to be installed, through
the general electrical panel.
If your installation does not have valves to close the water flow, you must drain the pool before
installing the equipment, otherwise all the water in the pool could be drained through the cut of
the pipe.
Please first identify the following elements in your pool installation:
Pump control panel (1)
Filtration pump (2)
Filter (3)
QUICKSALT chlorinator (4)
Please note that the
must always be installed after the pump and
filter. That is to say, on the drive. It is very
important that you identify the direction of the
water flow so that the elements are placed in
the following order:
Attention: Make sure you have a long enough length of pipe to install the
electrolysis cell.
The minimum measure required for this element is 35 cm.
38
QUICKSALT
chlorinator
4) Keep in mind that you will have to cut a
section of pipe and it is likely that this section is
full of water. Make sure you have the means to
collect this water when cutting.
5) Do not, under any circumstances, use power
tools to cut the PVC pipe. Use a hand saw.
1
3
2
Direction of the water
Drive
4