  • Page 1 Nutech 3000 Portable THC & NMHC Analyzer The Latest Generation of Portable VOCs Analyzer for Stationary Emission Source & Fence Line...
  • Page 2 VOCs analysis solutions & products for lab, online and portable applications. Nutech 3000 Portable THC & NMHC Analyzer is the latest generation product for portable VOCs analysis and we’ve made many improvements based on the existing products on the market.
  • Page 3 Why List NMHC as an Monitoring Target • TVOC can be represented by THC (CH4+NMHC) or NMHC. • CH4 is a non-toxic and unharmful gas and it accounts for the major part of THC. NMHC is the harmful & hazardous part in THC. Thus, to analyze toxic VOCs, NMHC is a more precise target than THC.
  • Page 4 ⚫ Research institutes. They can use this instrument on their VOCs research projects. Technology Principle TVOC can be represented by THC or NMHC. The Nutech 3000 adopts catalytic oxidation + double FIDs technology to simultaneously analyzes THC & NMHC. The sample gas is introduced to the analyzer by 2 channels. FID 1 analyzes the concentration of THC (total hydrocarbon) of the gas sample in channel 1.
  • Page 5 Technical Data • Detection Method: Catalytic Oxidation + Double FID • Measuring Range: 0~10/100/1000/10000 ppm (Automatic) • Detection Limit: ≤50ppb (Calculated by Carbon) • Zero Drift: ≤±1% Full Scale/8H • Span Drift: ≤±1% Full Scale/8H • Repeatability: ≤±0.1% Full Scale •...
  • Page 6 High Test Efficiency • New catalyst is used to achieve high conversion efficiency (≥95%) • Double FID design and can measure both THC & NMHC continuously at the same time without the need to switch gas flow. It can deliver NMHC test results as fast as every second. •...
  • Page 7 Version: 202008EN User Manual Nutech 3000 Analyzer for THC & NMHC...
  • Page 8 Unless otherwise specified, this manual is only applicable to Nutech 3000 analyzer for THC & NMHC. Due to product technology updates, Nutech reserves the right to change the product pictures and texts listed in this manual without prior notice.
  • Page 9: Table Of Contents

    Content SAFETY NOTICE ..............................4 SAFETY PRECAUTIONS ............................ 4 INSTRUMENT INTRODUCTION ........................6 USER NOTICE ..............................7 WARRANTY AND LIABILITY ..........................7 TRANSPORT AND STORAGE ........................... 8 DELIVERY CHECKLIST ............................8 INTRODUCTION OF INSTRUMENT COMPONENTS..................9 INSTALLATION AND COMMISSIONING ...................... 10 METAL HYDRIDE HYDROGEN CYLINDER USAGE INTRODUCTION ............
  • Page 10: Safety Notice

    Safety Notice The information identified by this symbol is essential to the health and safety DANGER of the operator. Actions that violate this symbol may cause harm to your health or personal safety. The information identified by this symbol is very important to ensure the WARNING normal operation of the instrument.
  • Page 11 has been carried out in accordance with IEC62133-2012 during the design and manufacturing process, users are obligated to comply with the relevant regulations for the transportation and safe use of lithium batteries in their country or region. Please use the original AC adapter to avoid overheating or other problems WARNING that may be caused by using adapters with different specifications Do not charge in direct sunlight or other high-temperature environments...
  • Page 12: Instrument Introduction

    4. Unplug the power plug of the instrument. Instrument Introduction The Nutech 3000 is an instrument for portable monitoring of total hydrocarbons, methane and non-methane hydrocarbons in stationary emission sources. The instrument is controlled by computer software and communicated through WiFi connection.
  • Page 13: User Notice

    Warranty and Liability According to the Nutech’s warranty, this instrument is guaranteed for 1 year. If there are any problems during the warranty period, please contact your supplier. You may also send the instrument directly to us with an invoice and problem descriptions and the freight is borne by you.
  • Page 14: Transport And Storage

    Send the instrument back properly packed in its original box. If the original packaging does not exist, please use other suitable packaging (please contact Nutech for details). Unpack Please carefully unpack and inspect the instrument.
  • Page 15: Introduction Of Instrument Components

    Introduction of Instrument Components Logo Power button Tablet computer Tablet computer holder Handle Sample extension tube Hydrogen cylinder switch knob Hydrogen inlet External cylinder air inlet Standard gas inlet Sample filter device heating tube Power jack...
  • Page 16: Installation And Commissioning

    Installation and Commissioning Please read the relevant operating instructions carefully. Nutech will be responsible for the safety, reliability and performance of the instrument only if the following tasks are done: ⚫ Operate the instrument according to the instructions ⚫ The operating place and hardware requirements are met...
  • Page 17: Metal Hydride Hydrogen Cylinder Usage Introduction

    ⚫ 2 to 3 meters of 1/8" clean Teflon tube or copper tube for air source ⚫ 0.5 to 1 meter of 1/16" clean silanized tube for standard gas Connector Inlet Connector Specifications 1/8″ Swagelok connector 1/8″ Swagelok connector Standard 1/8″...
  • Page 18: Instrument Functions

    Filling Hydrogen into Metal Hydride H2 Cylinder 1. Put the metal hydride hydrogen cylinder in ice water and connect it with the hydrogen tank. 2. Set the output pressure of the hydrogen tank to be 0.6Mpa. 3. Open the valve to introduce hydrogen into the metal hydride hydrogen cylinder. The cylinder will become hot shortly.
  • Page 19 3. When the instrument is turned on, it will automatically ignite. Wait for the device status to be idle which signify that the device is successfully warmed up. When the small circle of hydrogen status is red, it means that the pressure CAUTION of the hydrogen cylinder is insufficient.
  • Page 20 Sampling Mode 1. Single Click the small circle on the left of Single to select this mode. After setting the sampling time and cleaning time, the instrument will only take in one sample and analyze the data once. 2. Multiple...
  • Page 21 Click the small circle on the left of Multiple to set the interval time and Test Times. In this mode, the instrument performs analysis according to the set times and obtains the corresponding data. The interval time refers to the interval time between this data and the next CAUTION data, that is, the analysis period.
  • Page 22 Hydrogen & Air When the hydrogen and air are switched to the external mode, the output pressure of the cylinder can be seen at Status section. The cylinder pressure reducing valve shall be adjusted to proper level. It is recommended that the output pressure of the gas cylinder should not CAUTION exceed 50 psi, otherwise the valve inside the instrument may be damaged.
  • Page 23 2. External Mode Sample Gas: Sample gas is stored at canisters or Tedlar bags and then injected to the instrument. Standard Gas: High-pressure standard gas is injected to the instrument. If the sample runs at External model, the pressure should be controlled at 4 CAUTION psi-15 psi.
  • Page 24 baseline value (displayed real-time as the pA Value) of the instrument in Baseline section of Parameters Setting. Note that generally the pressure should be between 4 and 15 psi, otherwise it may cause flameout. When the baseline is stable, select the two baseline values of FID1 and FID2 and click OK.
  • Page 25 At this time, the instrument’s calibration is completed and can perform sample analysis. The output pressure of the cylinder should be between 4 psi to 15 psi at any CAUTION time. Management Click the Management button on the main interface and enter into the data management interface.
  • Page 26 Data Query 1. Click Query button or icon and select the start time and end time and then click OK. Data Printing Click the icon to pop up the interface and select the Bluetooth printer serial port. Enter the location and then click Print.
  • Page 27: Simple Operation Process

    2. Turn off the tablet computer 3. Disassemble the tracing pipe and sample probe 4. Press the Power button to turn off the instrument Note: Nutech 3000 can operate 24 hours continuously when connected to external power supply and external gas sources. Simple Operation Process 1.
  • Page 28: Accessories & Consumables

    Accessories & Consumables Item Number Item Name Ultra-clean filter Metal hydrogen cylinder Back-up tablet computer Back-up battery Zero air purifier Catalytic oxidation module Full system calibration adapter Zero air pump Features & Technical Data Features 1. Highly Integrated and Portable ⚫...
  • Page 29 ⚫ The new catalyst is used with high conversion efficiency (≥ 95%), fast gas path cleaning speed, which supports continuous and uninterrupted measurement. ⚫ Double FID and automatic flow path to enable the measuring of THC and CH4 simultaneously. 4. Controllable Process and Accurate Results Minimal loss of samples under high temperature (tracing pipe temperature over 180 ℃...
  • Page 30 T90 < 1 second Power 0.6 kW Operating Environment DC24V or AC ( 220±10% ) V/(50±2%) Hz, -20 ℃ ~50 ℃ , < 95%RH Operating Range Size 260W x 370L x 397H Nutech Instruments, Inc. Technical Support Call: 972-480-8908 Fax: 972-480-8308 E-mail: services@nutechins.com...
  • Page 31 Nutech 3000 The Latest Generation of Portable VOCs Analyzer for Stationary Emission Source & Plant Boundary...
  • Page 32 Nutech is the only company who VOCs can provide VOCs analysis solutions Analysis & products for lab, online and portable applications. Nutech 3000 Portable THC & NMHC Analyzer is the latest generation Online Portable product for portable VOCs analysis and we’ve made many improvements based on the existing products on the market.
  • Page 33 The Necessity for a Portable VOC Analyzer ⚫ The gas sample at emission source is hot and moisture. It is evitable to cause sample loss, adsorption and deterioration during sample collection transportation for lab analysis and thus the test results will be affected. ⚫...
  • Page 34 Why List NMHC as an Monitoring Target • TVOC can be represented by THC (CH4+NMHC) or NMHC. • CH4 is only a greenhouse gas while NMHC is the harmful & Unharmful substance. Accounts hazardous part in THC. Thus, to analyze toxic VOCs, NMHC for the major part of THC.
  • Page 35 Typical Applications of Nutech 3000 ⚫ Environmental inspection and law enforcement by government regulator ⚫ VOCs testing by commercial testing companies ⚫ Effectiveness evaluation of VOCs control measures ⚫ Self-inspection of VOCs emissions from chemical, printing and dyeing, spray painting companies ⚫...
  • Page 36 Typical Users of Nutech 3000 ⚫ Government environment protection regulators. They can bring this instrument to raid a suspected over-emission site and do test on-site to see if there is an over-emission. If yes, they can fine the owner. They can also use this instrument to do a before and after comparison to evaluate the effectiveness of their VOC control measures .
  • Page 37 Technology Principle of Nutech 3000 TVOC can be represented by THC or NMHC. The Nutech 3000 adopts catalytic oxidation + double FIDs technology to simultaneously analyzes THC & NMHC. The sample gas is introduced to the analyzer by 2 channels. FID 1 analyzes the concentration of THC (total hydrocarbon) of the gas sample in channel 1.
  • Page 38 Advantages of Nutech 3000 The most lightweight portable THC & NMHC Analyzer on the market so far. Less than 12 KG. • Easily portable by one person and thus less manpower invest when executing monitoring task. • Can be brought to inspection site by public transport like bus, metro, train.
  • Page 39 Advantages of Nutech 3000 Analyze THC & NMHC simultaneously with one single unit. • 2 monitoring targets with one analyzer. No need to purchase another NMHC analyzer. One analyzer for both THC & NMHC Competing products needs 2 units...
  • Page 40 Advantages of Nutech 3000 Competing product needs external gas supply Built-in H2 & zero air supply • H2 is supplied by mini built-in metal hydride cylinder with very low pressure and thus is safe and easy to handle and transport.
  • Page 41 Advantages of Nutech 3000 Adopt high precision EPC for precise flow control • The flow of H2, air and sample gas are all controlled by EPC. • Enhance the flow stability and thus ensure a better stability of testing data.
  • Page 42 • Perfect for emergency monitoring where customers need to analyze the gas as soon as they arrive at the site as the Nutech 3000 can pre-heat on road using battery. • No need to bring long extention (50m or 100m) power cables in case of the socket is very far away.
  • Page 43 Advantages of Nutech 3000 Catalytic oxidation + double FIDs design, can deliver test results as fast as every seconds. FID 1 for THC • Collect more data in limited time thus the test results is more representative. Sample Gas • Perfect for applications which the gas FID 2 for CH4 concentration changes rapidly.
  • Page 44 Advantages of Nutech 3000 Wide measuring range (0~10/100/1000/10000mg/m³) and low detection limite (<0.13 ppm) ensure it can be used for stack (extremely high concentration), inside the factory (medium concentration) and outside the factory (low concentration). Stack Inside the Factory Outside the Factory...
  • Page 45 Advantages of Nutech 3000 Sampling line can be heated up to 180℃ max to avoid sample condensation and adsorption. • Sample gas, especially sample gas in stack, is hot and moisture. In US, Europe and China, the standards require the temperature of the sampling line to be higher than the temperature of sample gas to avoid...
  • Page 46 Advantages of Nutech 3000 Silanized sampling line to avoid sample adsorption. • Silanization is a special surface treatment technology to make the surface utmost inert by adding a special coating to avoid sample adsorption and thus ensure the most accurate test results.
  • Page 47 Advantages of Nutech 3000 System can be purged automatically or manually for utmost cleanliness. • There is a cleaning process between every analysis. The cleaning time can be set. • Customer can also implement manual purge. • Purge function can keep the system clean and thus deliver more accurate test results.
  • Page 48 Advantages of Nutech 3000 Detachable Microsoft Surface Go tablet for instrument control and data reading and process. • The most convenient and intuitive way to control the instrument. • Test data can be exported in Excel file and printed easily (the tablet is running on WIN 10 ).
  • Page 49 Advantages of Nutech 3000 Working Temperature -20~50℃ • The wide working temperature is specially useful in markets where the temperature in winter is lower than 0℃.
  • Page 50 Advantages of Nutech 3000 No need disposable gas bottle and thus keep the running cost minimal. • The running cost of Nutech 3000 is the lowest in it kind. Competing products need disposable gas bottle...
  • Page 51 Thank You for Your Time Nutech Instruments, Inc. 1825 Summit Ave, Suite 200, Plano, TX 75074 +1 972 480 8908 +1 972 480 8308 info@nutechins.com www.nutechinst.com...