G2-HYDROMET Quick Start

For best results, setup your new product in the office/lab. Collect a few
data points and become familiar with the system prior to field deployment.
1
Go to
V2.WQDataLIVE.com/Getting-Started
2
Create a new account or sign into an existing
account and enter the Claim Code found on
the serial label to access the device's data
3
Place the HYDROMET in an area with strong
cellular coverage and connect the antenna
4
Connect the Solar Pack's UW-6 to the
HYDROMET's UW-6 pigtail to power the device
(device will beep once when powered)
5
Refresh WQData LIVE and confirm the Diagnostic
Data Last Contact timestamp has been updated
(May take up to 1 minute*)
6
Deploy the device by screwing it onto a
leveled 2" NPT pole and orienting it
north using the Airmar alignment mark
7
Angle the solar panel by removing the
outter angle adjustment bolt with the
included 3/16" hex wrench, tilting to the
desired angle (30° or 45°), and replacing the bolt
Connect Optional Hydrological Sensor
8
Connect the Hydrological sensor to the UW-8 pigtail
9
On WQData, click the G2-HYDROMET's
righthand Site List panel to access the Remote Device
Configuration dialog and queue a Detect Sensors and Sensor
Read command (check the boxes and click SAVE)
10
Cycle power (UW-6 pigtail) to
execute the remote command
11
Confirm the new parameters
are online (May take up to 3
minutes for detection and
upload)
icon in the
Serial Label

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the G2-HYDROMET and is the answer not in the manual?

Questions and answers

Summary of Contents for NexSens G2-HYDROMET

  • Page 1 (30° or 45°), and replacing the bolt Connect Optional Hydrological Sensor Connect the Hydrological sensor to the UW-8 pigtail On WQData, click the G2-HYDROMET’s icon in the righthand Site List panel to access the Remote Device Configuration dialog and queue a Detect Sensors and Sensor...
  • Page 2 Repair/Replace the battery pack below 9V or Hydrology data reports Visually inspect sensor and contact Sensor damaged errors NexSens for RMA authorization Sensor Visually inspect cable for cuts and disconnected or check connection is secure and dry Hydrology data cable damaged...

Table of Contents