SPECIFICATIONS
MODEL
9506-2200
VOLTAGE
220
50
FREQUENCY
HORSEPOWER 1/2
1725
RPM
WEIGHT (LBS) 35
10"H 18"W 8 1/2"D
DIMENSIONS
TROUBLE-SHOOTING
PROBLEM
No power or Main Switch not lit up
when unit is plugged into power out-
let
Main Switch lit up but motor not
turning when activated
Main Switch lit up & motor hums or
runs only in reverse when activated.
Motor running but Flexible Shaft not
turning
Motor running but no water output
at end of Flexible Shaft
Motor running and water drips in-
side unit
Unit running rough and/or noisy
Thomas C. Wilson, LLC
21-11 44th Avenue, Long Island City, New York 11101
Tel: (800) 230-2636 Fax: (718)361-2872 http://www.tcwilson.com
8
E-mail: tcwilson@tcwilson.com
SM-275
9600-2200
220
50
1/2
1725
55
12"H 23"W 11 1/2"D
CAUSE & SOLUTION
Power is not on
—flip Main switch to ON position
GFCI Plug not reset
—press reset button on GFCI
GFCI Plug defective
Main switch defective
Leakage in air-activated switch system
—defective Foot Pedal
—defective air switches
Defective motor
Short-circuit of wiring
Defective air switches
—replace air switch
Broken Safety Coupling
Water supply not turn on
Defective Solenoid Valve
—Worn Teflon seal inside Motor Connector
—Leakage in tube or tube fittings
Lack of lubrication in Motor Connector
—grease ball bearings inside Motor Connector
through grease fitting through access hole in
bottom of unit
—replace worn or corroded ball bearings in
Motor Connector
WILS-AWAY
ELECTRIC TUBE CLEANER
OPERATING INSTRUCTIONS
&
SERVICE MANUAL
Rev: A, 1/20/2015
TO REDUCE THE RISK OF INJURY AND EQUIPMENT DAMAGE
USER MUST READ AND UNDERSTAND OPERATOR'S MANUAL.
Thomas C. Wilson, LLC
21-11 44th Avenue, Long Island City, New York 11101
Tel: (800) 230-2636 Fax: (718)361-2872 http://www.tcwilson.com
E-mail: tcwilson@tcwilson.com
SM-275
9506-2200
9600-2200
Need help?
Do you have a question about the 9506-2200 and is the answer not in the manual?