GAS WALL OVEN INSTALLATION INSTRUCTIONS
2. Connect Electricity to Gas Wall
Oven
For personal safety, these appliances must be
properly grounded.
This appliance is equipped with a three-
prong grounding plug for your protection against shock
hazard and must be plugged directly into a properly
grounded receptacle. Do not cut or remove grounding
prong from this plug.
The wall receptacle and circuit should be checked by a
qualified electrician to make sure the receptacle is
properly grounded.
Preferred Method
Grounding
type wall
receptacle
Figure 2
Where a standard 2-prong wall receptacle is installed, it
is the personal responsibility and obligation of the
consumer to have it replaced by a properly grounded 3-
prong wall receptacle.
Do not, under any circumstances, cut or remove the
third (ground) prong from the power cord.
If an external electrical source is used, the appliance,
when installed, must be electrically grounded in
accordance with local codes or in their absence of local
codes with the National Electric Code ANSI/NFPA No.
70-1987 or latest edition.
Check all code rules and regulations for connecting the
wall oven to be certain the installation conforms with all
local, municipal and state codes as well as local utility
regulations.
Failure to comply with the above could result in a
serious shock hazard.
Note: All hookups and adjustments shall be performed
by qualified technicians.
Disconnect electrical supply cord from
wall receptacle before servicing wall oven.
Do not, under any
circumstances, cut,
remove, or bypass
the grounding
prong.
Power supply cord with
3-prong grounding plug
3. Alternate construction
(Model with 1½ oven cavity only)
Installation Instructions for installing a 1½ cavity oven into
an existing 2 cavity opening with dimensions 42 1/8" height
by 22 ½" Width.
1"
1. Height adjuster - lower height adjuster 1".
2. If width opening is too wide to secure unit to cabinet
with mounting screws, add filler strips.
3. 2" X 4" (standard 1 ½" X 3 ½") 22" minimum - stand
upright and flush with front cabinet. Secure to floor or
wall.
4. Lower trim (not shown) - overlap cabinet front (at bottom
of cutout ¼" minimum.
3
22 ½"
1
42
/
"
8
3"
Figure 3
2"