Download Print this page
CCL ELECTRONICS C3123A User Manual

CCL ELECTRONICS C3123A User Manual

Wireless pm2.5/pm10 air quality sensor

Advertisement

Quick Links

WIRELESS PM2.5/PM10 AIR QUALITY SENSOR
Model: C3123A
User Manual
FCC STATEMENT
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) this device may not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired operation.
Warning: Changes or modifications to this unit not expressly approved by the party responsible for
compliance could void the user's authority to operate the equipment.
NOTE:
This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This equipment generates, uses and can
radiate radio frequency energy and, if not installed and used in accordance with the instructions,
may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a n a circuit different from that to which the receiver is
connected.
- Consult the dealer or an experienced radio/TV technician for help.
" FCC RF Radiation Exposure Statement
Caution: To maintain compliance with the FCC's RF exposure guidelines, place the unit at least
20cm from nearby persons."
Thank you for purchasing the Wireless PM2.5/PM10 Air Quality Sensor. Please read the instructions
carefully according to the version you purchased and keep the manual well for future reference.
IMPORTANT NOTE
- Read and keep these instructions.
- Do not cover the ventilation holes with any items such as newspapers, curtains etc.
- Do not clean the unit with abrasive or corrosive materials.
- Do not tamper with the unit's internal components. This invalidates the warranty.
- Only use fresh batteries. Do not mix new and old batteries.
- Do not dispose old batteries as unsorted municipal waste. Collection of such waste separately
for special treatment is necessary.
- Attention! Please dispose of used unit or batteries in an ecologically safe manner.
- Technical specifications and user manual contents for this product are subject to change without
notice.
- CAUTION: Risk of explosion if the battery is replaced by an incorrect type.
- High or low extreme temperatures that a battery cannot be subjected to during use, storage or
transportation and low air pressure at high altitude.
- Replacement of a battery with an incorrect type that can defeat a safeguard.
- Disposal of a battery into fire or a hot oven, or mechanically crushing or cutting of a battery, that
can result in an explosion.
- Leaving battery in an extremely high temperature surrounding environment that can result in an
explosion or the leakage of flammable liquid or gas.
- A battery subjected to extremely low air pressure that may result in an explosion or the leakage
of flammable liquid or gas.
- The sensor is intended for use only with the rechargeable Ni-MH batteries provided:
Manufacturer: BPI
Model: BPI-50AA2000EHmAh (with marking 50AA2000mAh)
- This device is only suitable for mounting at height < 2m.
INTRODUCTION
Why PM2.5?
PM2.5 (particles less than 2.5 micrometers in diameter) can penetrate deeply into the lungs,
irritate and corrode the alveolar wall, and consequently impair lungs function, thus triggering
asthma attack or contributing to cardiovascular disease. Example of PM2.5 are fine dust from
vehicle exhaust, wildfire, power plant emissions, other combustion activities.
Why PM10?
PM10 (particles less than 10 micrometers in diameter) can irritate exposed mucous such as the
eyes and throat. Thus high levels of PM10 could easily make people cough, nose run and eyes
sting. PM10 includes dust from construction sites, highways, roadways, landfills and agriculture,
wind fires and bush/waste burning, industrial source; wind-blown dust from open lands, pollen,
mold spores, and fragments of bacteria.
Swiss sensor technology with MCERTS certification
The device comes with Swiss made SENSIRION Particulate Matter Sensor SPS series
designed for indoor and outdoor air quality application. Its measurement principle is based on
laser scattering and innovative contamination-resistance technology, which enables precise
measurements from the device's first operation and throughout its lifetime of usage.
Multi-zone feature
Through our multi-zone technologies, each device has a unique device code with a user
selectable channel number. Up to 4 separate air quality sensors can be placed in an open
proximity covering an area across 100m radius from its main display unit (to be purchased
separately).
Low maintenance
The Swiss sensor is expected to have a lifetime of over 10 years while operating continuously
for 24 hours/day. With its contamination-resistance material, there is no need for cleaning and/or
maintenance, thus avoiding problems related to sensor drift or malfunction.
OVERVIEW
1. LCD display
2. [ MODE ] key
3. [ CHECK ] key
4. Wall mounting holder
BATTERY INSERTION
1.
Unscrew and remove the battery door of sensor with a
screwdriver.
2.
Insert the 3 rechargeable batteries (included) into the battery compartment in the
following order:
x 3
3.
Screw the battery door compartment on tightly.
4.
After inserting batteries, all LCD segment will be shown for 1 second.
Note:
- Please prepare a screwdriver for removing and close the battery door.
GETTING STARTED
1.
Slide [ CHANNEL ] to set the channel number for your sensor(s).
2.
Use a pin to press [ RESET ] key for run the channel number.
Note:
- If there are more than one sensor in use, ensure to assign different channels number
for each sensor to enable the measurement to displayed correctly on the console
(purchase of separately).
LCD DISPLAY
1.
PM2.5 / PM10 display mode
2.
PM2.5 / PM10 concentration value
3.
PM2.5 / PM10 concentration level
4.
Sensor Wireless channel number
5.
Transmission signal
6.
Battery power indicator
DISPLAY MODE
Press [ MODE ] to toggle the display mode between PM10 and PM2.5.
MEASUREMENT INTERVAL
Powered by DC adapter
The device measures PM2.5 or PM10 concentration every minute automatically when powered
with a DC adapter.
Manual detection
User can press [ CHECK ] button anytime to get an updated measurement of PM2.5 or PM10
concentration readings. (It takes approximate 10-12s to detect, the readings indicated by
blinking PM2.5/PM10 icon.)
Operated by batteries
When powered by batteries, it's detecting every 10 minutes by default. To maximize the battery
life, user can also change the detection interval from 10 minutes to 20 or 30 minutes.
Setting default measurement interval
1.
Press and hold [ CHECK ] for 2 seconds until the display is flashing
2.
Press [ MODE ] to choose which interval time.
3.
The setting sequence: 10m
5. [ CH1 ~ 4 ] slide switch
6. [ RESET ] key
7. Battery compartment
8. DC adapter USB power port
3
1
2
1
2
3
20m
30m
4
5
6

Advertisement

loading

Summary of Contents for CCL ELECTRONICS C3123A

  • Page 1 OVERVIEW WIRELESS PM2.5/PM10 AIR QUALITY SENSOR Model: C3123A User Manual FCC STATEMENT This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
  • Page 2 PAIRING WIRELESS SENSORS TO CONSOLE DISPLAY Press [ CHECK ] to finish the setting and back to normal display. This Wireless PM2.5/PM10 Air Quality Sensor can connect to the Air Quality Display console. Detection interval Description After power up the wireless air quality sensor, it will automatically enter registration (Minute) mode for 10 minutes until which it can be paired by the display console.