Dato F500 Quick Operation Manual

Dato F500 Quick Operation Manual

Smart thermostat

Advertisement

Quick Links

F S m a r t T h e r m o s t a t
Q u i c k O p e r a t i o n G u i d e

Advertisement

Table of Contents
loading

Summary of Contents for Dato F500

  • Page 1 F S m a r t T h e r m o s t a t Q u i c k O p e r a t i o n G u i d e...
  • Page 2: Technical Parameters

    Introduction The F500 thermostat is used to control up to 2 stages of heating levels and 2 stages of cooling levels with 8 types of control systems, EM heat activation, adjustable compressor delay time and O/B changeover. It has a tempered glass screen, quick connection terminals to save on installation time.
  • Page 3 Introduction CAUTION: ELECTRICAL HAZARD Can cause electrical shock or equipment damage. Disconnect power before beginning installation. CAUTION: EQUIPMENT DAMAGE HAZARD Compressor protection is bypassed during testing. To prevent equipment damage, avoid cycling the compressor quickly. CAUTION: MERCURY NOTICE If this product is replacing a control that contains mercury in a sealed tube, do not place the old control in the trash.
  • Page 4 Display...
  • Page 5: Fan Modes

    Function & Settings Modes The thermostat had five modes: EM HEAT, HEAT, OFF, AUTO, COOL. * Note: EM HEAT can be activated in FACTORY SET. Press the options under mode bar to switch among EM HEAT (should be activated if needed), HEAT, OFF, AUTO, or COOL. Fan Modes The fan can be set to AUTO mode or ON mode.
  • Page 6: Set Working Mode

    Function & Settings Set Working Mode Press Menu, then the screen displays DATE TIME, then press Next once, when the screen displays SETUP WORKING MODE press Edit, once the screen displays SCHEDULE, press UP or DOWN arrow to switch between SCHEDULE and HOLD modes. After setting, press Done to exit.
  • Page 7: Set Schedule

    Function & Settings Set Up Wi-Fi Press Menu, then the screen displays DATE TIME, then press Next twice, then the screen displays SETUP WIFI, then press Edit, the screen displays SMART MODE, press UP or DOWN arrow to switch between SMART MODE and AP MODE.
  • Page 8: User Setup

    Function & Settings User Setup Press Menu, then the screen displays DATE TIME, then press Next 4times, then the screen displays USER SETUP, then press Edit to enter user setup interface.   1.USER SETUP: Press Edit to set the relative settings under User Setup. 2.TEMP SCALE: Press + or - to switch between ℃...
  • Page 9: Factory Set

    Function & Settings Factory Set Press Menu, then the screen displays DATE TIME, then press Next 5 times, then the screen displays FACTORY SET, then press Edit to enter the user setup interface. 1. FACTORY SET: Factory set includes system type, compressor protect, emergency heat mode and change over.
  • Page 10 Function & Settings Set Clean Screen Press Menu, then the screen displays DATE TIME, then press Next 6 times, then the screen will display CLEAN SCREEN, then press Done. The user will have 30 seconds to clean the screen without changing any setting. Set Reset Press Menu, then the screen displays DATE TIME, then press Next 7 times, then the screen displays RESET, then press + or - to change between ON and...

Table of Contents