Norka BUENOS AIRES UV-C 997 100 02 Series Operating Instructions Manual

Wall mounting

Advertisement

Quick Links

Operating instructions
BUENOS AIRES UV-C
Wall mounting
Article number 997 100 02 ..
Article number 997 180 02 ..
1

Advertisement

Table of Contents
loading

Summary of Contents for Norka BUENOS AIRES UV-C 997 100 02 Series

  • Page 1 Operating instructions BUENOS AIRES UV-C Wall mounting Article number 997 100 02 .. Article number 997 180 02 ..
  • Page 2: For Your Safety

    FOR YOUR SAFETY Read these operating instructions carefully before operating the unit and keep them for subsequent reference. > Make sure that no water, other liquids or flammable cleaning agents get into the unit to avert the risk of electric shock and/or fire.
  • Page 3: Technical Data

    TECHNICAL DATA Article number 997 100 ..997 180 ..Lamp OSRAM G36T8/OF HNS 36W G13 OSRAM G36T8/OF HNS 36W G13 ® ® Lamp service life 9000 h at +40 °C 9000 h at +40 °C Wavelength 253.7 nm 253.7 nm Air-flow rate 100 m³/h...
  • Page 4: Installation

    INSTALLATION Lamp control light 115 mm Ø 8,5 mm > Wall plug load capacity is designed for 12 kg. > Fit the housing into the wall bracket, with the lamp control light pointing down- wards towards the fl oor. > The spacer nut must be inside the recess of the wall bracket.
  • Page 5 Fastening nut (SW 10) Spacer nut...
  • Page 6: Maintenance

    COMMISSIONING Note the visible “blue” light has no harmful UV-C radiation. The BUENOS AIRES UV-C unit is designed for continuous operation. Commissioning should begin approx. one hour before the room is to be used to ensure that it functions properly. Note As the unit is delivered with new UV-C lamps, there may be a slight odour during the first hours of operation due to the burning-in process of the lamps.
  • Page 7: Replacing The Uv-C Lamp

    REPLACING THE UV-C LAMP A Wait until the unit has cooled down completely. B Remove the housing screws. C Pull the lamps towards the housing opening.
  • Page 8 D Insert the new lamps type OSRAM HNS 36W G13. E Check whether the lamp is centred in the socket.
  • Page 9: Troubleshooting

    Replace both UV-C lamps. No air flowing out of air Air inlet blocked Check the air inlet. outlet Fan defective Please contact NORKA Customer Service. Fan wheel is not turning al- Fan wheel blocked Check the air inlet for though green control lamp foreign bodies.
  • Page 10 SHUTDOWN Clean the unit and store it together with these instructions in a clean and frost-proof place. DISPOSAL When disposing of the unit or the UV-C lamp, observe the relevant legal regulations. Information on the disposal of electrical and electronic equipment in the European Com- munity: Within the European Community, the disposal of electrically operated devices is governed by national regulations based on the EU Directive 2012/19/EU on Waste Electrical and...
  • Page 11 Place/Date: Dörverden-Hülsen/ 10.06.2021 Issuer: Signed for and on behalf of: NORKA Norddeutsche Kunststoff- und Elektrogesellschaft Stäcker mbH und Co. KG v. Rudkowski, Head of Laboratory & Pre-development Schönfeld, CEO This declaration certifies the accordance with the stated regulations but doesn't include assurance of characteristics.
  • Page 12 Norddeutsche Kunststoff- und Elektro- T. +49 (0)40 513 009 0 gesellschaft Stäcker mbH & Co. KG info@norka.com Lichttechnische Spezialfabrik norka.com Weidestraße 122 a 22083 Hamburg Germany...