FOR YOUR SAFETY Read these operating instructions carefully before operating the unit and keep them for subsequent reference. > Make sure that no water, other liquids or flammable cleaning agents get into the unit to avert the risk of electric shock and/or fire.
TECHNICAL DATA Article number 997 100 ..997 180 ..Lamp OSRAM G36T8/OF HNS 36W G13 OSRAM G36T8/OF HNS 36W G13 ® ® Lamp service life 9000 h at +40 °C 9000 h at +40 °C Wavelength 253.7 nm 253.7 nm Air-flow rate 100 m³/h...
INSTALLATION Lamp control light 115 mm Ø 8,5 mm > Wall plug load capacity is designed for 12 kg. > Fit the housing into the wall bracket, with the lamp control light pointing down- wards towards the fl oor. > The spacer nut must be inside the recess of the wall bracket.
COMMISSIONING Note the visible “blue” light has no harmful UV-C radiation. The BUENOS AIRES UV-C unit is designed for continuous operation. Commissioning should begin approx. one hour before the room is to be used to ensure that it functions properly. Note As the unit is delivered with new UV-C lamps, there may be a slight odour during the first hours of operation due to the burning-in process of the lamps.
Replace both UV-C lamps. No air flowing out of air Air inlet blocked Check the air inlet. outlet Fan defective Please contact NORKA Customer Service. Fan wheel is not turning al- Fan wheel blocked Check the air inlet for though green control lamp foreign bodies.
Page 10
SHUTDOWN Clean the unit and store it together with these instructions in a clean and frost-proof place. DISPOSAL When disposing of the unit or the UV-C lamp, observe the relevant legal regulations. Information on the disposal of electrical and electronic equipment in the European Com- munity: Within the European Community, the disposal of electrically operated devices is governed by national regulations based on the EU Directive 2012/19/EU on Waste Electrical and...
Page 11
Place/Date: Dörverden-Hülsen/ 10.06.2021 Issuer: Signed for and on behalf of: NORKA Norddeutsche Kunststoff- und Elektrogesellschaft Stäcker mbH und Co. KG v. Rudkowski, Head of Laboratory & Pre-development Schönfeld, CEO This declaration certifies the accordance with the stated regulations but doesn't include assurance of characteristics.