Advertisement

Quick Links

WARNING: If the information in these instructions is not
followed exactly, a fire or explosion may result, causing
property damage, personal injury, or loss of life.
-
Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other
appliance.
WHAT TO DO IF YOU SMELL GAS
-
Do not try to light any appliance.
-
Do not touch any electrical switch; do not use any
phone in your building.
-
Immediately call you gas supplier from a neighbor's
phone. Follow the gas supplier's instructions.
-
If you cannot reach your gas supplier, call the fire
department.
-
Installation and service must be performed by a
qualified installer, service agency or the gas supplier.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
Installation and service of this appliance MUST be performed by qualified certified NFI personnel.
Massachusetts: The piping and final gas connection must be performed by a licensed plumber or gas
fitter in the State of Massachusetts. Also, see Carbon Monoxide Requirements Detector requirements.
Flare
Fireplaces Vent-Free Outdoor Installation Guide
Flare Double Corner, Left Corner, Right Corner, Front and See-Through v15.0
NOTICE
FOR OUTDOOR USE ONLY
1

Advertisement

Table of Contents
loading

Summary of Contents for Flare Fireplaces Flare-VFF-50

  • Page 1 NOTICE FOR OUTDOOR USE ONLY WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result, causing property damage, personal injury, or loss of life. Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
  • Page 2: Table Of Contents

    TABLE OF CONTENTS FIREPLACE SAFETY WARNINGS ..............................4 FLARE VENTLESS FIREPLACES – FRAMELESS IN EVERY WHERE ....................13 CERTIFICATION ..................................13 INSTALLATION MODEL LIST AND INTRODUCTION ........................14 WATER AND MOISTURE RESISTANCE ............................15 QUALIFIED INSTALLING AND INSTALLERS..........................15 HIGH ALTITUDES ..................................15 WELL HEAD GAS INSTALLATIONS ..............................16 OUTDOOR FIREPLACE INSTALLATION OVERVIEW........................16 OUTDOOR FIREPLACE ENCLOSURE REQUIREMENTS........................16 DRAINAGE AND VENTILATION ..............................18...
  • Page 3 WARRANTY POLICY...................................39 18 MONTH COMPREHENSIVE WARRANTY ..........................39 LIMITED FIVE-YEAR COVERAGE..............................39 LIMITED 10-YEAR COVERAGE ..............................39 CONDITIONS ....................................39 EXCLUSIONS.....................................40 WARRANTY VOID WHEN…................................40...
  • Page 4: Fireplace Safety Warnings

    FIREPLACE SAFETY WARNINGS WARNING DANGER, CARBON MONOXIDE HAZARD! This appliance can produce carbon monoxide, which has no odor. Using it in an enclosed space can kill you. Never use this appliance in an enclosed space such as a camper, tent, car, or home. WARNING Do not try to light this appliance without reading the “LIGHTING”...
  • Page 5 WARNING DANGER! HOT GLASS Hot glass and surface will cause burns. Do not touch glass until cooled. Never allow children to touch glass or surface surrounding the fireplace. WARNING COVER MUST BE REMOVED DURING OPERATION Carbon Monoxide Hazard DANGER This appliance can produce Carbon Monoxide which has no odor.
  • Page 6 SAFE OPERATING PRACTICES • This appliance is hot when operating and can cause severe burns if contacted. • Installation and repair should be done by a qualified service person. The appliance should be inspected before use and at least annually by a qualified service person. More frequent cleaning may be required, as necessary. It is imperative the control compartment, burners and circulating air passageways of the appliance be kept clean.
  • Page 7 • The pressure regulator and hose assembly supplied with LP models must be used. Replacement pressure regulators and hose assemblies must be those specified in this manual. • The LP gas supply cylinder used with LP models must be constructed and marked in accordance with the specifications for LP-gas cylinders as required by the U.S.
  • Page 8 WARNING This appliance is designed for non-combustible enclosures only and must be installed and serviced by a qualified installer to local codes. WARNING Minimum clearance to combustibles must be maintained or a serious fire hazard could result. WARNING Use only non-combustible materials (certified to ASTM E-136) such as steel studs, cement board, ceramic tile, marble, paint etc.
  • Page 9 WARNING RISK OF FIRE, EXPLOSION, OR ASPHYXIATION, ENSURE THERE ARE NO IGNITION SOURCES SUCH AS SPARKS OR OPEN FLAMES. The installation must be performed by a licensed gas fitter, and all connections must be leak tested before operating the appliance. •...
  • Page 10 • Any guard or protective device removed for servicing the appliance must be replaced prior to operating the appliance. • Installation and repair should be done by a qualified service person. • The appliance should be inspected before each use and at least annually by a qualified service person. More frequent cleaning may be required, as necessary.
  • Page 11 WARNING Glass embers may have a fine oil residue that needs to be cleaned prior to installation. Clean the glass with mild dish soap, drain, rinse thoroughly and dry before installing. Glass embers may have sharp edges, wear safety glasses and gloves when handling. Do not change or substitute the glass ember material provided with this appliance.
  • Page 12 WARNING • Never use this appliance for other than the intended use. Do not use this appliance to prepare food. • You must have clear and easy access to the on/off valve AFTER the appliance is installed and connected to the gas supply to safely turn off the burner. •...
  • Page 13: Flare Ventless Fireplaces - Frameless In Every Where

    FLARE VENTLESS FIREPLACES – FRAMELESS IN EVERY WHERE Flare Fireplaces is where innovation, quality and luxury come together to form new ideas. By combining superior raw materials, contemporary design, creative technology, and a frameless way of thinking, we have created a full line of direct-vent fireplaces that are luxurious, simple to operate, and efficient.
  • Page 14: Installation Model List And Introduction

    • Flare Vent-Free Double Corner 50” - 100“ All Outdoor Vent Free Flare Fireplaces are made using a combination of 3.16 & 3.04 stainless steel. All models share the same gas valve system, gas connection, glass type and burner, simplifying installation and operation.
  • Page 15: Water And Moisture Resistance

    When installed on exterior walls: Flare Fireplaces recommends the fireplace chase be constructed outside the structure's weather envelope. Where the platform meets the wall, use a flashing detail like that required for attached decks.
  • Page 16: Well Head Gas Installations

    WELL HEAD GAS INSTALLATIONS Some natural gas utilities use "well head" gas. This may affect the Btu output of the unit. Contact the gas company for the heating value. Contact the manufacturer or your gas company before changing spud/orifice size. OUTDOOR FIREPLACE INSTALLATION OVERVIEW When selecting a location for your appliance it is important to ensure clearances to adjacent combustibles are met.
  • Page 17 Within a partial enclosure which includes an overhead cover and no more than two side walls. These side walls may be parallel, as in a breezeway or at right angles to each side. Within a partial enclosure which includes an overhead cover and three sidewalls if 30 percent or more of the horizontal periphery of the enclosure is permanently open.
  • Page 18: Drainage And Ventilation

    DRAINAGE AND VENTILATION Flare Fireplaces recommends leaving the included Storm Doors on the fireplace when it is not in use, to prevent any accumulation of moisture inside the unit. Although the fireplace is designed to operate outdoors safely, rain and other sources of moisture may enter the fireplace cavity, which may cause water to collect inside the chase and base of the unit within the fireplace enclosure.
  • Page 19: Clearances

    CLEARANCES CLEARANCES TO COMBUSTIBLE FRAMING TOP: 4” BOTTOM: 0” SIDE: 2” BACK: 2” COMBUSTIBLE PERPENDICULAR SIDE-WALL: 36” FRONT OF FIREPLACE TO COMBUSTIBLES: 36” CLEARANCES TO COMBUSTIBLE FINISHING MATERIALS LETTER DESCRIPTION CLEARANCE TO COMBUSTIBLE FROM GROUND OR OTHER CONBUSTIBLE SURFACE 11” FROM SIDE WALLS 6”...
  • Page 20 LETTER DESCRIPTION MEASUREMENT FROM OPENING FROM GROUND OR ANOTHER COMBUSTIBLE SURFACE 11” FROM SIDE WALLS 6” FROM CEILING (MINIMUM) 36” ALCOVE WIDTH (MINIMUM FIREPLACE LENGTH + 12” NON-COMBUSTIBLE BOARD ABOVE OPENING 8” MINIMUM NOTE: SEE INSTALLATION MANUAL FOR ALL CLEARANCES AND REQUIREMENTS. TYPE-X NOT ALLOWED AS NON-COMBUSTIBLE BOARD OVER APPLIANCE OPENING...
  • Page 21: Mantel Clearance

    MANTEL CLEARANCE The use of non-combustible material for mantel is recommended. If using combustible materials, follow the chart below. Note: When using paint or lacquer to finish the mantel, the paint or lacquer must be heat resistant to prevent discoloration. The Following clearance chart can be used for non-combustible & combustible mantel Warning! Do not attach combustible material to the mantel of your fireplace.
  • Page 22: Electrical Requirements

    PLEASE DO NOT OPERATE THE OUTDOOR FIREPLACE USING ANY SMART DEVICE OR 3 PARTY AUTOMATION SYSTEMS WHILE NOT IN DIRECT SIGHT OF THE FIREPLACE. ALL OUTDOOR FLARE FIREPLACES USE AN OPEN FLAME PRESENTATION & REQUIRE ITS OPERATOR TO BE PRESENT FOR OPERATION OF THE FIREPLACE...
  • Page 23: Gas Connection

    GAS CONNECTION The gas appliance is designed to operate with Natural gas or Liquid propane gas. Verify the fireplace you have is set to operate with the input gas type for your installation. Convert your unit if needed. Ensure that the flexible connector is protected from damage.
  • Page 24: Liquid Propane Gas Conversion

    DIRECTLY TO A GAS LP CYLINDER. - CONTACT FLARE FIREPLACES SUPPORT FOR GAS CONVERSION KITS FOR VENT FREE FIREPLACES. - THE FLARE FIREPLACES VENT FREE FIREPLACE WAS NOT DESIGN OR INTENDED TO BE CONNECTED DIRECTLY TO A GAS LP CYLINDER.
  • Page 25: Waterproof Electrical Connection

    WATERPROOF ELECTRICAL CONNECTION POWER CABLE INFORMATION: - 3 wire Cable according to the USA standard color Green (GND), Black (Line), white (Neutral). - 16 AWG up to 10A, AC 110v. The use of a dedicated power source is recommended. GFCI protected 15A. - Waterproof connector is prewired with plastic leads that will need to be replaced upon connection.
  • Page 26: Electrical Drawing For Inside Ventless Core

    ELECTRICAL DRAWING FOR INSIDE VENTLESS CORE...
  • Page 27: Ventless Power Board

    VENTLESS POWER BOARD Ventless Fireplaces have a small electronic Board installed inside the ventless box it used to manage and control the Electric Draw from the Source power to the Honeywell Valve using the Proximity Sensor. 1. POWER SOURCE: ELECTRICAL POWER SOURCE 110V AC. 2.
  • Page 28: Rgb Led Lights

    RGB LED LIGHTS Flare Fireplace is shipped with a multi-color interior RGB LED lighting installed and connected. The lights allow perfect flames to be viewed across a bed of illuminated crushed glass. RGB LED - Multi color option controlled by a remote control for color selection. Once the color has been selected by the operator, the next time LED is used, the system will remember and maintain color selected.
  • Page 29: Media Arrangement

    MEDIA ARRANGEMENT Flare Fireplace can be equipped with different media types. Follow the instruction below for information on how to add and arrange media in your Fireplace: • Do not place any type of media on the pilot or in front of the pilot. Keep 1” distance from the pilot to allow correct operation of the pilot.
  • Page 30: Wind Guard Glass Installation

    WIND GUARD GLASS INSTALLATION The wind glass guard has been designed to protect and save the flame from being affected by the wind during operation, the following pictures are showing the installation process. PLACE THE GLASS INTO THE GLASS HOLDER AS SHOWING IN THE PICTURE BELOW. WIND GUARD GLASS MAY HAVE 2 OR 3 HOLDERS FOR EACH PART IT DEPENDS ON THE LENGTH OF THE FIREPLACE.
  • Page 31 TIGHTEN THE SCREWS OF THE GLASS HOLDER USING A POWER SCREWDRIVER AS SHOWN IN THE PICTURES BELOW.
  • Page 32: Rain Doors

    RAIN DOORS The fireplace covers are designed to be used during storage time only. Make sure to remove the covers prior to use. Never operate the fireplace with any of the covers attached to the unit (Front or sides). REMOVE ALL COVERS PRIOR TO ATTEMPTING TO START THE FIREPLACE THE FIREPLACE COVERS ARE ONLY FOR STORAGE DO NOT START THE FIREPLACE WITH THE COVERS ATTCHED The Vent free cover are designed to keep your fireplace dry and clean during storage time.
  • Page 33: Reflective Back Installation

    REFLECTIVE BACK INSTALLATION Flare Fireplace may be ordered with a reflective ceramic glass backing. The ceramic glass is tinted black to create a reflection when the fireplace is running. The ceramic glass will enhance and protect the fireplace look and is very easy to clean. The reflective back is shipped outside the unit, inside a sleeve with the other glass panes.
  • Page 34: Installation Steps

    INSTALLATION STEPS Prior to starting the installation, make sure you read and understand all WARNING information in the manual. Do not start the installation if you are not clear about any of the installation related subjects. DETERMINE THE FOLLOWING: • Clearance requirements from combustible and non-combustible materials. Follow the clearance instruction and example in the manual.
  • Page 35: Fireplace Unpacking

    FIREPLACE UNPAC KING Follow the instructions below for unpacking the unit: • Check the packing and confirm there is no external damage. If damage exists, please notify Flare Fireplaces immediately. • Remove the top wood studs and pull the external carton box up.
  • Page 36: Maintenance

    MAINTENANCE WARNING • IT IS RECOMMENDED THAT A QUALIFIED SERVICE TECHNICIAN PERFORM A ROUTINE INSPECTION AT THE BEGINNING OF EACH HEATING SEASON. • DISCONNECT POWER BEFORE ATTEMPTING MAINTENANCE OR REPAIR OF THE FIREPLACE. • INSTALLATION AND MAINTENANCE MUST BE PERFORMED BY AN AUTHORIZED QUALIFIED INSTALLER, SERVICE AGENCY OR GAS SUPPLIER.
  • Page 37: Yearly Service Plan

    YEARLY SERVICE PLAN Failure to inspect and maintain the fireplace may lead to improper combustion and a potentially dangerous situation. We recommend the following procedures be done by a qualified technician. GLASS MAINTENANCE • Always use gloves when removing the glass to protect your hand and prevent fingerprints on the glass. •...
  • Page 38: Maintenance Log

    MAINTENANCE LOG FLARE FIREPLACES – MAINTENANCE LOG Following document should be used by the service technician. A copy should be kept with the technician and owner for future reference Service Date: ___________________ UNIT INFORMATION Model Type and Size: ____________________________________________________ Serial #: _______________________________________________________________ OWNER INFORMATION Name: ________________________________________________________________...
  • Page 39 WARRANTY POLICY Flare Fireplaces subjects every fireplace and component to rigorous testing to verify it is free from any defects before it leaves our warehouse. Flare Fireplaces photographs and documents the fireplace and all components’ moments before shipping them to our nationwide network of authorized dealers for installation, verifying full operation of the fireplace and all components.
  • Page 40 Flare Fireplaces is not responsible for installation, operational or environmental conditions beyond our control. • Flare Fireplaces shall in no event be liable for any special, indirect, or consequential damages of any nature which are more than the original purchase price of the product. •...