5 of DPR n 447 dated 06/12/1991, “Regulation implementing of law 5 March 1990, n 46” and in compliance with law 6 December 1971, n 1083 “Safety standards for the use of fuel gas”, declares SFK 28 - RAD - ING - Manuale - 1801.1_V3...
1. INSTALLER SECTION 1. INSTALLER SECTION The installation operations described in this section should be performed only by qualified personnel, having the appropriate technical training in the field for the installation and maintenance of components of civil and industrial domestic hot water production and heating plants.
Failure to observe this caution will void a grid that does not hamper the useful section the warranty of the heat exchanger. of passage. SFK 28 - RAD - ING - Manuale - 1801.1_V3...
1.1.3. REFERENCE LEGISLATION The installation must be realized according to the requirements of current legislation and in compliance with local technical regulations, according to the indications of the good technique. SFK 28 - RAD - ING - Manuale - 1801.1_V3...
› Turn the water heater at 90° holding it with your hand (fig. 1-B). › Lift the box (fig. 1-C) and remove the guards (fig. 1-D). fig. 1 SFK 28 - RAD - ING - Manuale - 1801.1_V3...
1.1.8. RECIRCULATION MODE CIRCULATOR PREVALENCE/FLOW DIAGRAM ZRS 12/6 FLOW RATE (m Circulator priority maximum speed Circulator head at second speed Circulator head at minimum speed Appliance Loss SFK 28 - RAD - ING - Manuale - 1801.1_V3...
In order to prevent limestone build-up and damages to the domestic water heat exchanger, the hardness of the domestic supply water should not exceed 15 °f. However, please check SFK 28 - RAD - ING - Manuale - 1801.1_V3...
53 °C. When this temperature is achieved, the appliance shuts-off whilst the pump keeps running. The appliance is activated again when the temperature falls to 50 °C. SFK 28 - RAD - ING - Manuale - 1801.1_V3...
(see chapters ‘DIGITECH CS PARAMETERS TABLE’ and ‘ACCESSING AND PROGRAMMING THE PARAMETERS’); › Set the temperature setpoint of the D.H.W. tank by pressing ‘ ’ and ‘ ’ the sanitary (fig. fig. 3 SFK 28 - RAD - ING - Manuale - 1801.1_V3...
“T” (fig. 1); › Connect the dedicated flexible condensate draining tube to a waste disposal system. The condensate can be drained directly in the sewerage system by inserting an easily serviceable siphon. SFK 28 - RAD - ING - Manuale - 1801.1_V3...
(230 V) and gas supply. For long periods of standby, please empty the water heater. If the temperature goes below -10 °C please insert electrical resistances kit (cod. 82259LP). SFK 28 - RAD - ING - Manuale - 1801.1_V3...
WARNING It is strictly forbidden the use of adaptors, multiple plugs and/or extensions for the general power supply of the equipment from the electrical network. SFK 28 - RAD - ING - Manuale - 1801.1_V3...
· the blue cable to the terminal marked with “N”. · the brown cable to the terminal marked with “L”. After performing these operations, remount plate “A” and the front casing. SFK 28 - RAD - ING - Manuale - 1801.1_V3...
2). › After removing the plate, connect the electrical cables to terminal “B” (see fig. 2); › After performing these operations, remount plate “A” and the front casing. fig. 2 SFK 28 - RAD - ING - Manuale - 1801.1_V3...
Page 22
Cut off the voltage from the main switch. › remove the boiler’s front casing (refer to chapter ACCESSING THE WATER HEATER). COD.40-00017 fig. 3 COD.40-00360 SFK 28 - RAD - ING - Manuale - 1801.1_V3...
› Make sure that the discharge tube doe not protrude inside the fumes exhaust duct, stop before it reaches the inner surface of the latter. SFK 28 - RAD - ING - Manuale - 1801.1_V3...
The ducts must be certified for this specific use and for a temperature greater than 100 °C. SFK 28 - RAD - ING - Manuale - 1801.1_V3...
Page 25
The locations in which are installed gas devices must be vented so as to ensure the amount of air necessary for a regular combustion and for location ventilation. The natural air intake must take place directly through: SFK 28 - RAD - ING - Manuale - 1801.1_V3...
Subsequent addition of a curve is similar to adding a linear length of tube according to the indications below: co-axial curve Ø60/100 at 90° = 1 m co-axial curve Ø60/100 at 45° = 0.6 m SFK 28 - RAD - ING - Manuale - 1801.1_V3...
Page 27
Subsequent addition of a curve is similar to adding a linear length of tube according to the indications below: curve Ø80 at 90°= 1.5 m curve Ø80 at 45°= 1.2 m SFK 28 - RAD - ING - Manuale - 1801.1_V3...
Page 28
Subsequent addition of a curve is similar to adding Ø100 a linear length of tube according to the indications below: Ø 60 curve Ø60/100 at 90° = 1 m curve Ø60/100 at 45° = 0.6 m SFK 28 - RAD - ING - Manuale - 1801.1_V3...
1. SUPPORT CENTRE SECTION 2. SUPPORT CENTRE SECTION All operations described below relative to first start- up, maintenance and replacement should be performed only by qualified personnel and authorized by RADIANT BRUCIATORI S.p.A.
Local and National Laws and Standards; › make sure that the heating system gate valves are open; › make sure that there is no intake of gaseous products within the system; SFK 28 - RAD - ING - Manuale - 1801.1_V3...
Before repeating the operation, wait at least 5 seconds from the last start-up attempt and unlock the water heater from “E01” error code by pressing the Reset ‘ ’ key. SFK 28 - RAD - ING - Manuale - 1801.1_V3...
› Open several D.H.W. taps at the highest flow rate. › Access parameter ‘P07’ following the procedure described chapter “ACCESSING fig. 2 PROGRAMMING THE PARAMETERS” and stay in edit mode until the calibration is completed SFK 28 - RAD - ING - Manuale - 1801.1_V3...
’with the message ‘P00’, and release the keys ‘ ’ and ‘ ’. Use the keys ‘ ’ and ‘ ’ of the symbol recirculation to select the parameter to be edited. SFK 28 - RAD - ING - Manuale - 1801.1_V3...
Page 34
To exit the parameters menu, hold at the same time the keys ‘ ’ and ‘ ’ and wait for the symbol ‘ ’ to appear on the display. SFK 28 - RAD - ING - Manuale - 1801.1_V3...
RECIRCULATION DIFFERENTIAL ACTIVATION 5 - 15 VALUE EXPRESSED IN °C THROUGH THIS PARAMETER YOU CAN ANTICIPATE RECIRCULATION FUNCTION, COMPARED RECIRCULATION POINT PRESET BY THE END-USER, BY MODIFYING THE TEMPERATURE DIFFERENCE. SFK 28 - RAD - ING - Manuale - 1801.1_V3...
Page 36
THE TIME NECESSARY FOR THE WATER HEATER TO REACH THE MINIMUM SET POWER, AFTER THE BURNER START-UP. TYPE OF UNIT SELECTION 0 - 1 0 = °C - l/min 1 = °F - gpm SFK 28 - RAD - ING - Manuale - 1801.1_V3...
Page 37
HOT WATER TREATMENT (AND INFORM THE USERS) TO AVOID UNFORSEEABLE DAMAGES TO PERSONS, ANIMALS AND PROPERTY. THERMOSTATIC VALVE SHOULD BE INSTALLED AT THE DOMESTIC HOT WATER OUTLET TO AVOID ANY BURNS. SFK 28 - RAD - ING - Manuale - 1801.1_V3...
Page 38
PUMP OPERATION IN WATER HEATER MODE 0 - 1 0 = DISABLED THROUGH THIS PARAMETER YOU CAN ACTIVATE/DEACTIVATE THE CIRCULATING PUMP DURING THE NORMAL OPERATION 1 = ENABLED OF THE WATER HEATER. SFK 28 - RAD - ING - Manuale - 1801.1_V3...
› remove and clean the burner from oxidation; condensate. › check the integrity and the position of the sealed chamber sealing gasket; SFK 28 - RAD - ING - Manuale - 1801.1_V3...
Page 40
2. MAINTENANCE › check that the liquid flow is not obstructed and that there are no combustion gas refluxes inside the internal system. SFK 28 - RAD - ING - Manuale - 1801.1_V3...
Max discharge length Ø50/50 - Hor Split Max discharge length Ø60/60 - Hor Split Max discharge length Ø80/80 - Hor Split Max discharge length Ø50 - Hor duct Max discharge length Ø60 - Hor duct SFK 28 - RAD - ING - Manuale - 1801.1_V3...
Page 42
Fuel consumption - G30 kg/h 2.13 Nominal Supply pressure - G31 mbar D.H.W Max fan speed - G31 D.H.W Min. fan speed - G31 Fuel consumption - G31 kg/h 2.10 SFK 28 - RAD - ING - Manuale - 1801.1_V3...
SAFETY VALVE 8 bar AIR RELIEF VALVE 10. DOMESTIC HOT WATER OUTLET PROBE 11. SAFETY THERMOSTAT 12. AIR SUCTION TUBE 13. PROPORTIONAL VENTURI 14. CONDENSATE COLLECTION SIPHON 15. NO RETURN VALVE 16. CIRCULATOR SFK 28 - RAD - ING - Manuale - 1801.1_V3...
Page 45
(RECIRCULATION NON ACTIVE) (RECIRCULATION NON ACTIVE) (POST-CIRCULATION ACTIVE) D.H.W. PRODUCTION THRU A REMOTE TANK D.H.W. CIRCUIT MIXING VALVE RECIRCULATION PUMP RECIRCULATION STORAGE TANK D.H.W. STORAGE TANK SENSOR EXPANSION VESSEL WATER NETWORK SFK 28 - RAD - ING - Manuale - 1801.1_V3...
SRC: RECIRCULATION PROBE L: LINE GI: YELLOW TRA:START-UP TRANSFORMER MP: PANEL TERMINAL N: NEUTRAL BI: WHITE TF: FUMES THERMOFUSE (102°C) EV: ELECTRIC FAN NE: BLACK GR. GREY MF: FLUXMETER RO: RED SFK 28 - RAD - ING - Manuale - 1801.1_V3...
› remove the fastening screws (2 - fig.1) placed on the front edge of the side panel; › grab the bottom of the panel and remove it by moving it sideways and then pulling it upwards (see fig. 1). SFK 28 - RAD - ING - Manuale - 1801.1_V3...
(fig. 1) loosening them and turn the panel downwards; › unscrew the four fastening screws 1 - fig. 1; › remove the crankcase pulling it upwards. fig. 1 SFK 28 - RAD - ING - Manuale - 1801.1_V3...
› close the main supply tap of the water supply network; › open all cold and hot water taps; › after completing all operations, close the discharge tap and all previously opened water taps. SFK 28 - RAD - ING - Manuale - 1801.1_V3...
IF THE TENSION MEASURES BETWEEN PHASE-PHASE NEUTRAL AND GROUND IS ALMOST EQUAL TO THE ONE MEASURED BETWEEN PHASE AND GROUND, YOU HAVE TO INSTALL A PHASE-PHASE TRANSFORMER KIT (COD. 88021LA) SFK 28 - RAD - ING - Manuale - 1801.1_V3...
Page 51
KOHM AT 25 °C NTC); DISCONNECTED OR WET CHECK THE WIRING. PROBE CONNECTOR. ELECTRIC FAN ELECTRIC FAN BOARD REPLACE IT; AUTOMATIC. BROKEN; ELECTRIC FAN BROKEN; REPLACE IT; FAULTY POWER SUPPLY REPLACE IT. CABLE. SFK 28 - RAD - ING - Manuale - 1801.1_V3...
Page 52
SUPPLY VOLTAGE OFF THE CHECK THE POWER SUPPLY AUTOMATIC. OPERATION RANGE ( 160 NETWORK (THE ERROR DEACTIVATES VOLTS). AUTOMATICALLY AS SOON AS THE SUPPLY VOLTAGE FALLS BACK WITHIN THE REQUESTED LIMITS). SFK 28 - RAD - ING - Manuale - 1801.1_V3...
YOU CAN ACTIVATE/DEACTIVATED IT BY HOLDING SIMULTANEOUSLY AND FOR 7 SECONDS THE RESET ‘ ’ AND ‘ ’ OF THE SYMBOL RECIRCULATION . THE “FAST H2O” FUNCTION GUARANTEES THE IMMEDIATE D.H.W SUPPLY AT THE REQUESTED TEMPERATURE. SFK 28 - RAD - ING - Manuale - 1801.1_V3...
‘GAS TYPE SELECTION’ from the control panel fig. 3 (see chapters ‘DIGITECH CS PARAMETERS TABLE’ and ‘ACCESSING AND PROGRAMMING THE PARAMETERS’); › adjust the CO2 combustion value as indicated in chapter ‘CO2 VALUE CHECK AND CALIBRATION’. SFK 28 - RAD - ING - Manuale - 1801.1_V3...
1. USER SECTION 3. USER SECTION The operations described in this section are addressed to all those who will use the machine. The machine must be used and accessed only by qualified operators that fully read and understood the User section, paying particular attention to the warnings.
DANGER DO NOT obstruct the air vents of the location in which the gas device is installed to prevent the formation of toxic explosive mixes. SFK 28 - RAD - ING - Manuale - 1801.1_V3...
OPERATING MODE SELECTION KEY: ON/ OFF RESET KEY: FAULTS RESET DOMESTIC WATER TEMPERATURE ADJUSTMENT KEY / HOLD THE KEYS AT THE SAME TIME FOR 5 SECONDS TO ACTIVATE DISPLAY BACK LIGHT FOR 10 MINUTES DISPLAY SFK 28 - RAD - ING - Manuale - 1801.1_V3...
MODULATING POWER LEVEL OF THE WATER HEATER (fig.2) ≤ 33% >33%<66% >66%<100% OPERATION IN DOMESTIC MODE ENABLED ERROR DISPLAY THAT CAN BE RESET OFF OPERATING MODE ERROR DISPLAY THAT CAN NOT BE RESET fig. 2 SFK 28 - RAD - ING - Manuale - 1801.1_V3...
To exit display mode press the INFO ‘ ’ key. LIST OF DISPLAYED DATA INFO CODE DESCRIPTION COLD CIRCUIT INLET PROBE TEMPERATURE HOT WATER CAPACITY FAN SPEED RECIRCULATION PROBE TEMPERATURE SFK 28 - RAD - ING - Manuale - 1801.1_V3...
30 °C to 45 °C. OFF MODE In this mode the water heater no longer meets the domestic hot water demands, the anti-freeze and pump anti-locking systems still remain active. SFK 28 - RAD - ING - Manuale - 1801.1_V3...
CUT OFF THE POWER SUPPLY FROM THE MAIN SWITCH AND REQUEST THEN RESTORE IT, AS SOON AS THE ERROR CODE DISAPPEARS, THE WATER HEATER WILL RESTART AUTOMATICALLY. IF THE BLOCK PERSISTS CONTACT THE TECHNICAL SUPPORT CENTRE. SFK 28 - RAD - ING - Manuale - 1801.1_V3...
Page 62
’ BUTTON ON THE CONTROL PANEL TO RESET THE FAULT, AS SOON AS THE ERROR CODE DISAPPEARS FROM THE DISPLAY, THE WATER HEATER WILL START AUTOMATICALLY. SUPPLY VOLTAGE CONTACT THE TECHNICAL SUPPORT CENTRE. SFK 28 - RAD - ING - Manuale - 1801.1_V3...
› water wastes are limited waiting that the water reaches the right temperature. To activate/deactivate the Fast H2O function please follow the instruction indicated in the paragraph ‘ACTIVE FUNCTIONS SIGNALLING CODES’. SFK 28 - RAD - ING - Manuale - 1801.1_V3...
(Waste Electrical and Electronic Equipment) shows that this product can not be dismantled as domestic waste. Proper dismantle of this product helps preventing potentially negative consequences on human health and environment. SFK 28 - RAD - ING - Manuale - 1801.1_V3...