Adjusting The Hi Prox Sensor - Air Weigh BinMaxx Cloud Installation Manual

For front end loaders
Table of Contents

Advertisement

10. Raise the forks slowly and immediately stop raising once the
display changes to a four digit number.
11. Re-measure the tube height to make sure the center of the
tube is approximately 48" to 52" from the ground.
12. Repeat Steps 7 to 12 until the fork height is consistently the
height identified in Step 2 (48" to 50")
13. Turn off the truck. Tighten the LO PROX target completely.

Adjusting the HI PROX Sensor

1. Start the truck and wait for the scale to power up.
2. Raise the arm torque tube between 98" and 102" from the
ground, as close to 100" as possible.
3. From the scale display, follow the steps below:
Press ESC to reach the main menu.
Use ▲ or ▼ to select DIAGNOSTICS. Press ENTER.
Use ▲ or ▼ to select ECU. Press ENTER.
Use ▲ or ▼ to select SENSOR DATA. Press ENTER.
The A/D readings will display on the BinMaxx Cloud
screen. Press ▼ until you see the data that reads PROX
SWITCHES along with values.
4. When both the low and high prox sensors are in the off
position, the LO PROX and HI PROX values displayed on the
BinMaxx Cloud scale should be a low number, between 0-5.
5. Rotate the HI PROX sensor target that was installed earlier
around the arm tube. The HI PROX number on the BinMaxx
Cloud display will change from between 0 to 5 to above 1,000
when the sensor is activated.
6. Rotate the target clamp so that the sensor is activated at the
very edge of the clamp.