The cabinet supports up to two units of SR670 and corresponding rail kit. For optimal use of space, it is
advised to determine the location to install the rail kits based on the number of units that are installed.
• One unit: 1-3U
• Two units: 1-3U and 4-6U
Notes:
• The left and right mounting glides are part of the fire enclosure. Therefore, ensure the glides are installed
before attempting to mount the server in vertical orientation.
• Two people are required for this task.
• When installing SR670 in the rack cabinet, do not mix it with SE350 or SR250 in the same cabinet.
See the following table to identify the components that come with the mounting kit.
1
Two C-channels
2
One left mounting glide
3
One right mounting glide
P P r r o o c c e e d d u u r r e e
Step 1.
Remove the two screws that secure the lower portion of SR670 rack mounting brackets on both
sides, and dispose the screws.
4
Four black M3.5 x 5 mm flat head screws with pre-
applied threadlocking adhesive
5
Ten black M5 x 20 mm combination head screws
Chapter 6
.
31
Installing optional kits