    Table of contents General safety information ....................4     Safe operation ......................... 4   Technical Data ........................ 6     Mechanical installation ....................7     Electrical installation ..................... 12     Limit switch adjustment ....................13     Motor connection ......................
  • Page 4: General Safety Information

    The safe operation of the product can only be ensured if it is used as specified. Follow the installation instructions. Observe all specifications, especially warnings, when installing the product in the overall system. GfA is not liable for damage resulting from non-observance of the installation instructions. The resulting overall system must be reassessed for its safety in accordance with applicable standards and directives (e.g.
  • Page 5 Warning - Failure to follow these installation instructions may result in severe injury or death.  Please read these instructions before using the product.  Keep these instructions handy.  Include these instructions when passing on the product to third parties. Warning - Danger from improper use of the product! ...
  • Page 6: Technical Data

    2 Technical Data Type SG 50 Output torque Output speed Output shaft / hollow shaft 25,00 Maximum output speed open / close 42 / 24 for frequency inverter operation Supply voltage 3N~ 400 Operating current 1,20 Operating frequency Power factor cos φ 0,87 Maximum movement per hour Hand forces...
  • Page 7: Mechanical Installation

    3 Mechanical installation Prerequisites The permissible loads on walls, fastenings, mountings and transmission elements must not be exceeded, even for maximum holding torques or locking torques (▶ refer to technical data). Connection elements ▶ Self-locking connection ▶ Utilize the hole diameter ▶...
  • Page 8 Transmission elements ▶ Install the chain wheel ▶ Position the chain wheels Tighten the chain wheel properly. properly. properly. BAGAB00022_Z001 BAGAB00021_Z001...
  • Page 9 Mounting Four holes are provided for mounting. BAGAD0 1 2 0 1 _Z0 0 3...
  • Page 10 Installation The descriptions below apply to general door specifications. The specifications of the door manufacturer must also be observed during installation. Warning - Potential injury or danger to life!  During installation, be sure to use a lifting device that has a sufficient load- carrying capacity.
  • Page 11 ▶ Mount the drive unit. Do not tighten yet. BAGAE0 1 2 0 3 _Z0 0 2 ▶ Position the chain wheel (①) properly. BAGAE0 1 2 0 4 _Z0 0 2 Install the chain wheel (②). Secure the chain wheel (③). ▶...
  • Page 12: Electrical Installation

    4 Electrical installation Warning - Danger to life from electric current!  Switch the mains OFF and check that the cables are de-energised  Observe the applicable regulations and standards  Make a proper electrical connection  Use suitable tools Performing electrical installation Remove the cover.
  • Page 13: Limit Switch Adjustment

    5 Limit switch adjustment The adjustment of the final limit positions OPEN and CLOSE is described in the instructions for the door control panel.
  • Page 14: Motor Connection

    6 Motor connection Motor X13 Motor plug 7 Alternative motor connection Motor X13 Motor plug...
  • Page 15: Limit Switch Connection

    8 Limit switch connection Thermal contact S10 Emergency manual operation X12 DES connection Safety circuit Channel B (RS485) Ground Channel A (RS485) Safety circuit Supply voltage...
  • Page 16: Emergency Manual Operation (Emergency Hand Crank)

    9 Emergency manual operation (emergency hand crank) The emergency manual operation is designed for opening or closing the door without power supply. Its activation interrupts the control voltage. Electrical operation is no longer possible. Warning – Injuries due to incorrect operation or falling objects! ...
  • Page 17 Warning – Risk of injury due to uncontrolled movements and falling objects! The drive unit could start up unexpectedly and injure people should a wrong emergency hand crank be used. A wrong crank will drop out of the mounting and injure people.
  • Page 18: Completing Commissioning / Inspection

    10 Completing commissioning / inspection Check the following components and then install all covers. Gearbox Check the drive unit for loss of oil (a few drops can be neglected). Protect the output-shaft permanently against corrosion. Mounting Check that all connection elements (consoles, torque mounts, screws, locking rings, etc.) are secure and in proper condition.
  • Page 19: Declaration Of Incorporation / Declaration Of Conformity

    EMC Directive 2014/30/EU within the meaning of RoHS Directive 2011/65/EU The following requirements from Appendix I of GfA ELEKTROMATEN GmbH & Co. KG the Machinery Directive 2006/42/EC are met: declare under our sole responsibility that the 1.1.2, 1.1.3, 1.1.5, 1.2.2, 1.2.3, 1.2.6, 1.3.2,...