Rough-In Dimensions/Capacities; Installation Clearances; Levelling - A.O. Smith DB/DW-720-1810 User Manual

Natural gas-fired commercial cross flow copper boilers for hydronic heating and hot water supply
Table of Contents

Advertisement

Label all wires prior to disconnection when servicing controls. Wiring
errors can cause improper and dangerous operation.
"Verify proper operation after servicing."
ROUGH-IN DIMENSIONS/
CAPACITIES

INSTALLATION CLEARANCES

These boilers are approved for installation on combustible flooring
in an alcove with minimum clearance to combustibles See chart
below.
AN AMPLE SUPPLY OF AIR MUST BE PROVIDED
FOR PROPER COMBUSTION AND VENTILATION.
TABLE 1, ROUGH-IN DIMENSIONS
Models
DW-720
DW-840
Dimensions
inches
mm
inches
A
46 1/2
1181
52 1/5
B
29 5/8
752
29 5/8
C
54 3/4
1391
54 3/4
D
1 1/4 NPT
1 1/4 NPT
E
7 3/4
197
7 3/4
F
15 1/2
394
15 1/2
G
17 1/4
438
17 1/4
H
4 1/4
108
4 1/4
J
2 NPT
K
2 NPT
L
1 NPT
M
12
305
14
N
15 1/2
394
16 1/2
W
32 1/8
816
31 1/8
Approx.
Shipping
780 lbs 354 Kg. 950 lbs 431 Kg 950 lbs 431 Kg 1000 lbs 454 Kg 1075 lbs 488 Kg. 1100 lbs 499 Kg 1125 lbs 510 Kg 1150 lbs 522 Kg 1250 lbs 567 Kg
Weight.
All Models
CAUTION
WARNING
DW-960
DW-1080
mm
inches
mm
inches
1326
57 3/4
1467
52 7/8
752
29 5/8
752
32 3/4
1391
54 3/4
1391
58
1 1/4 NPT
1 1/4 NPT
197
7 3/4
197
7 1/2
394
15 1/2
394
18 1/2
438
17 1/4
438
18 9/16
108
4 1/4
108
4
2 NPT
2 NPT
2 1/2 NPT
2 NPT
2 NPT
2 1/2 NPT
1 NPT
1 NPT
1 1/4 NPT
356
14
356
16
419
16 1/2
419
17 1/4
791
32 1/8
816
30 15/16
Minimum Clearances To Combustibles
Water
Top
Side
12" (305mm)
18" (457mm)
Two inch clearance is allowable from combustible construction for
hot water pipes.
Sufficient clearance should be provided at one end of the boiler to
permit access to heat exchanger tubes for cleaning. Maximum
operating water supply pressure 160 psi. Gas supply pressure:
13.8" w.c. max., 5.5" w.c. min.
Sufficient area should be provided at the front and sides of the unit
for proper servicing. Clearances of 48" in front and 24" on sides is
recommended. In a utility room installation, the door shall be wide
enough to allow the boiler to enter or to permit the replacement of
another appliance.
Each unit should be checked after installation to be certain that it is
level.
DW-1210
DW-1350
mm
inches
mm
inches
1343
58 1/2
1486
64 1/2
832
32 3/4
832
32 3/4
1473
58
1473
58
1 1/2 NPT
1 1/2 NPT
191
7 1/2
191
7 1/2
470
18 1/2
470
18 1/2
471
18 9/16
471
18 9/16
102
4
102
4
2 1/2 NPT
2 1/2 NPT
2 1/2 NPT
2 1/2 NPT
1 1/4 NPT
1 1/4 NPT
406
16
406
18
438
17 1/4
438
17 1/4
786
30 15/16
786
30 15/16
Blank
Side
Rear
6" (155mm)
6" (155mm)
3

LEVELLING

DW-1480
DW-1610
mm
inches
mm
inches
1638
69 1/2
1765
75
832
34
864
34
1473
60 1/2
1537
60 1/2
1 1/2 NPT
2
NPT
191
7 1/2
191
7 1/2
470
18 1/2
470
18 1/2
471
19 1/8
486
19 1/8
102
4 1/2
114
4 1/2
2 1/2 NPT
2 1/2 NPT
2 1/2 NPT
2 1/2 NPT
1 1/4 NPT
1 1/4 NPT
457
18
457
18
438
13 3/4
349
13 3/4
786
31
787
31
Vent
Front
6" (155mm)
Alcove
DW-1810
mm
inches
mm
1905
82 1/2
2096
864
34
864
1537
60 1/2
1537
2
NPT
191
7 1/2
191
470
18 1/2
470
486
19 1/8
486
114
4 1/2
114
2 1/2 NPT
2 1/2 NPT
1 1/4 NPT
457
20
508
349
13 3/4
349
787
31
787

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents