Kambic OB-15/2 BB User Manual

Kambic OB-15/2 BB User Manual

Calibration bath with black body cavity
Table of Contents
  • Introductions
  • Technical Data
  • Instructions for Use
  • Basic Setup
  • Control Panel with Touch Display
  • Main Screen
  • Info Screen
  • Unlock Screen
  • Graph Screen
  • Main Settings
  • Pid Parameter Settings
  • Special Settings
  • Temperature Corrections
  • Stop Screen
  • Back Panel
  • Service and Maintenance
  • Draining the Bath
  • Requires Space and Conections
  • Safe Use and Safety Elements
  • Dismantling and Disposal
  • Troubleshooting
  • RS 232 Communication Protocol
  • Attachments
  • Declarations
  • Electrical Drawings

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
User Manual
Calibration Bath
With Black Body Cavity
OB-15/2 BB

Advertisement

Table of Contents
loading

Summary of Contents for Kambic OB-15/2 BB

  • Page 1 User Manual Calibration Bath With Black Body Cavity OB-15/2 BB...
  • Page 2 Kambic d.o.o. Kambic d.o.o. shall in no event be liable for incidental or consequential damages, including without limitations, lost profits, loss of income, loss of business opportunities, loss of use, and other related exposures, caused by incorrect use of product.
  • Page 3: Table Of Contents

    User Manual OB-15/2 BB CONTENT 1. WARNINGS AND SAFETY PRECAUTIONS... 2. INTRODUCTIONS ..........3. TECHNICAL DATA ..........4. INSTRUCTIONS FOR USE ........4. 1 Basic Setup ............4.2 Control Panel With Touch Display ......4.2.1 Main Screen ............. 4.2.2 Info Screen ............
  • Page 4: Warnings And Safety Precautions

    In no event shall Kambic d.o.o. be held liable for any damages, direct or incidental related to the use of this product and manual. Product can be equipped with variety of accessories and options. This warning list might include elements that are applicable only with certain models and accessories.
  • Page 5 User Manual OB-15/2 BB DANGER OF FIRE Heating of flammable materials is not allowed! WARNING Use only distilled or demineralized water for humidity maintenance system! Close the doors tightly before start! Do not open doors during the cycle! DANGER OF BURNS...
  • Page 6 Informationen oder Stellungnahmen info@kambic.com zu kontaktieren. Keinesfalls kann Kambic d.o.o. für Schäden jeglicher Art durch Verwendung dieses Produktes oder Handbuchs, direkt oder indirekt, verantwortlich gemacht werden. Das Produkt kann mit verschiedenen Zubehörteilen und Optionen ausgestattet sein. Die Warnungsliste kann Punkte enthalten, die nur auf bestimmte Modelle und Zubehörteile zutreffend sind.
  • Page 7 User Manual OB-15/2 BB BRANDGEFAHR Beheizung von entzündlichen Materialien ist nicht zulässig! WARNUNG Nur destilliertes oder entionisiertes Wasser für die Luftfeuchtigkeitsregelung verwenden! Türen vor dem Start dicht schließen und im Betrieb nicht öffnen! GEFAHR VON VERBRENNUNGEN Verwenden Sie bei hohen/niedrigen Temperaturen Sicherheitshandschuhe! EXPLOSIONSGEFAHR Verwenden Sie keine Materialien, die eine explosionsfähige Atmosphäre...
  • Page 8 En aucun cas Kambic d.o.o. ne pourra être tenu responsable pour quelques dommages directs ou accidentels que ce soient liés à l’utilisation de ce produit ou de ce manuel. Le produit peut être équipé de nombreux accessoires et options. Cette liste de mises en garde est susceptible de contenir des éléments n’étant applicables qu’à...
  • Page 9 User Manual OB-15/2 BB RISQUE D’INCENDIE Interdiction de chauffer des matériaux inflammables! ATTENTION N’utiliser que de l’eau distillée ou déminéralisée pour le système de maintien d’humidité ! Fermez les portes fermement avant de démarrer ! N’ouvrez pas les portes pendant le cycle! RISQUE DE BRÛLURES...
  • Page 10 Sociedad limitada Kambic d.o.o. en ningún caso será responsable de ningún tipo de daños directos o incidentales resultantes de la utilización de este producto y manual. El producto puede ser provisto de una variedad de accesorios y opciones. Esta lista de advertencias puede incluir elementos aplicables sólo a algunos modelos y accesorios.
  • Page 11 User Manual OB-15/2 BB PELIGRO DE INCENDIO Mantener alejado de fuentes de calor, chispas, llama abierta o superficies calientes! No fumar! ADVERTENCIA ¡Utilice sólo agua destilada desmineralizada para sistema mantenimiento de la humedad! ¡Cierre la puerta ajustadamente antes de comenzar! ¡Durante el ciclo no...
  • Page 12 дилеру или к нам через за дополнительной информацией или info@kambic.com мнением. Ни при каких обстоятельствах Kambic d.o.o. не несет ответственности за любые повреждения, прямo или косвенно связанные с использованием данного изделия и руководства. Изделие может быть оснащено разнообразными аксессуарами и опциями. Этот список предупреждений...
  • Page 13 User Manual OB-15/2 BB ОПАСНОСТЬ ВОСПЛАМЕНЕНИЯ Нагревание воспламеняющихся материалов запрещено! ПРЕДУПРЕЖДЕНИЕ Используйте только дистиллированную или деминерализованную воду для системы поддержания влажности! Плотно закройте двери перед запуском! Не открывайте двери во время цикла! ОПАСНОСТЬ ОЖОГОВ При работе с высокими / низкими температурами используйте защитные...
  • Page 14: Introductions

    User Manual OB-15/2 BB INTRODUCTIONS Calibration bath OB-15/2 BB was developed and manufactured specifically for the calibration of temperature instruments, probes and liquid thermometers at temperatures from +40°C to 300°C. Fluid calibration baths ensure high temperature stability and uniformity across working volume. To ensure such specifications all calibration baths of our brand are designed with a special double cylinder construction with uniform vertical flow in the working volume.
  • Page 15: Technical Data

    User Manual OB-15/2 BB TECHNICAL DATA OB–15/2 BB Width 530 mm Height 1090 mm Depth 470 mm Working chamber dimensions 225 x 270 mm Volume ~ 15 L Temperature range +40°C…+250 °C Temperature Stability Better than ± 0.005°C Temperature homogeneity Better than ±...
  • Page 16: Instructions For Use

    User Manual OB-15/2 BB INSTRUCTIONS FOR USE 4.1 Basic setup Step 1: Fill the bath with appropriate fluid (up to 80%) Step 2: Connect the power cord into the power supply 230V±10%; 50/60Hz Step 3: Put the main switch in position 1 (on the back of the device)
  • Page 17: Main Screen

    User Manual OB-15/2 BB 4.2.1 Main screen Set temperature Bath temperature Black: temperature in tolerances (set value ±0.05°C) Red: temperature too high Blue: temperature too low Fluid stirrer in operation Heating in operation (flashing) Settings button Graph button Unlock button INFO button 4.2.2 INFO screen...
  • Page 18: Unlock Screen

    User Manual OB-15/2 BB 4.2.3 Unlock screen Press Unlock button to see this screen: Enter unlock code 0207 Press to Lock Press OK to confirm and unlock Enter unlock code 0207 and confirm with OK button to enable edit PID settings and temperature corrections.
  • Page 19: Main Settings

    User Manual OB-15/2 BB 4.2.5 Main settings Touch value to select You can set each decimal     place separately! Set temperature Set LCD brightness Decrease value Increase value Next screen Previous (main) screen 4.2.6 PID parameter settings ...
  • Page 20: Special Settings

    User Manual OB-15/2 BB 4.2.7 Special settings Touch value to select  Fluid mixing speed After changing this parameter wait for a few minutes for the system to stabilize!!! Never change for more than a few % at a time! Set the frequency for the temp.
  • Page 21: Stop Screen

    User Manual OB-15/2 BB 4.2.9 STOP screen If you press stop button (1 second or more) to stop the cycle you will see this screen: This will immediately stop temperature control! 4.2.10 Back panel Main switch Power supply cable Over temperature safety device shaft Over temp.
  • Page 22: Service And Maintenance

    Maintenance and service within the warranty period may only be performed by the authorized service person. Please advise Kambic in before alternation & modification. It is not allowed to change or rebuild any part of the construction without producer's written permit.
  • Page 23: Draining The Bath

    User Manual OB-15/2 BB 5.1 Draining the Bath All our calibration baths are designed and equipped with drain valve for safe and quick draining of bath fluid. Do to extremely high and low temperatures special metal seal valve is selected, assuring leakage free operation even at extreme temperatures and large valve flow section at the same time.
  • Page 24: Requires Space And Conections

    User Manual OB-15/2 BB REQUIRED SPACE AND CONECTIONS The appliance must be installed at least 200 mm away from the nearest wall. It must also be in a dry and well ventilated room. Additional space or relocation of the apparatus may be necessary when carrying out any maintenance or servicing.
  • Page 25: Safe Use And Safety Elements

    User Manual OB-15/2 BB SAFE USE AND SAFETY ELEMENTS It is not allowed to heat-up any material which could form explosive atmosphere. Cycle may only be started when the cover is closed. Do not store any fluids on top of the housing! Microprocessor controller has a special safety system which turns heaters off if temperature rises for more than 5 °C above set temperature.
  • Page 26: Dismantling And Disposal

    User Manual OB-15/2 BB DISMANTLING AND DISPOSAL This symbol means do not dispose of your product with your other household waste. Instead, you should protect human health and the environment by handing over your waste equipment to a designated collection point for the recycling of waste electrical and electronic equipment.
  • Page 27: Troubleshooting

    User Manual OB-15/2 BB TROUBLESHOOTING Fluid drip from bath check fluid level ➔ ➔ check catch pod Temperature stability & uniformity ➔ check fluid level and fluid flow ➔ check stirring operating ➔ check fluid viscosity ➔ check temperature sensor Increased noise ➔...
  • Page 28: Rs 232 Communication Protocol

    User Manual OB-15/2 BB RS-232 COMMUNICATION PROTOCOL COM port settings: 9600 Baud No parity 8 Data bit 1 Stop bit Connector pins info: = TXD RS232 output from controller = GND = RXD RS232 input to controller All commands must be written in capital letters and identical as written in this description! After the receipt of the command (START, STOP, SETTEMP) the data is immediately written in the eeprom.
  • Page 29: Attachments

    User Manual OB-15/2 BB Attachments 11.1 Declarations 11.2 Electrical Drawings...

This manual is also suitable for:

Ob-15/2 bblt

Table of Contents