Download Print this page
Haws 2000SMS Installation Manual

Haws 2000SMS Installation Manual

Bottle filler with lifecycle control

Advertisement

Quick Links

1455 Kleppe Lane Sparks, NV 89431-6467 (888) 909-4297
Model 2000SMS/2000SMSN
Bottle Filler with Lifecycle Control
NOTE: A Class A ground-fault circuit interrupter
(GFCI) shall be installed in the branch-circuit
supplying power to this unit.
SHOULD YOU EXPERIENCE DIFFICULTY WITH THE INSTALLATION OF THIS
MODEL, OR REQUIRE REPLACEMENT PARTS, PLEASE CALL:
HOURS OF OPERATION: MON-THURS 7:00a.m. - 4:30p.m PT, FRI 7:00a.m.- 11:00a.m. PT
PARTS LIST: 1 Bottle Filler, 1 filter cartridge, 1 plastic drain basin, 1 hex key, 1 grommet.
RECOMMENDED TOOLS: Phillips screwdrivers, level.
REQUIRED PARTS (NOT SUPPLIED): 1/2" screwdriver stop, 3/8" tubing (to be used for water
supply inlet), 6 1/8" x 3" zinc-plated steel toggle bolts, 6 zinc-plated steel 1/8" fender washers.
PRODUCT INSTALLATION: When installing this product, local, state or federal codes should be
adhered to. This unit is certified for indoor use only.
SUPPLY LINE: Minimum recommended line size is 1/2" IPS with 30-90 PSI (2-6 ATM) flowing
pressure; supply water is to be cold water supply. Intended for municipal water only.
PLUMBING CONNECTIONS: Inlet is 3/8" O.D. push-in type fitting. If a waste is desired, the Haws
6470 retrofit 1-1/4" O.D. waste kit may be used.
ELECTRICAL CONNECTIONS: 115VAC, 60HZ, approx. 0.14A. Unit is equipped with a standard
115VAC plug.
RATED SERVICE FLOW: 0.5 GPM (2725L/day)
OPERATING TEMPERATURE: 35–100
OPERATING PRESSURE: 30-90 PSI
FILTER CAPACITY: 2500 gallons (9460L) or 1 year
REPLACEMENT FILTER CARTRIDGE: Electronic Lifecycle Control Filter Model 6423
®
© 2017 Haws
Corporation – All Rights Reserved
®
HAWS
and other trademarks used in these materials are the exclusive property of Haws Corporation.
08/17
 website:
www.Hawsco.com
TECHNICAL SUPPORT:
1-800-766-5612
QUICK START REFERENCE
°
F (1.7–37.8
Model 2000SMS/2000SMSN
INSTALLATION GUIDE
CAUTION! Prior to making any electrical
connections, verify with a voltmeter that power
from the service panel is off.
°
C)
No. 0510000664 (2)
Page 1 of 5

Advertisement

loading

Summary of Contents for Haws 2000SMS

  • Page 1 SUPPLY LINE: Minimum recommended line size is 1/2" IPS with 30-90 PSI (2-6 ATM) flowing pressure; supply water is to be cold water supply. Intended for municipal water only. PLUMBING CONNECTIONS: Inlet is 3/8” O.D. push-in type fitting. If a waste is desired, the Haws 6470 retrofit 1-1/4” O.D. waste kit may be used.
  • Page 2: Installation Procedure

    5. There is an opening in the bottom of the unit to accommodate a plumbed waste. If a plumbed waste is desired, the Haws model 6470 retrofit kit may be used. Step 1: To open the unit, slide the supplied hex key into the notch in the left-hand side of the hinged upper plastic panel and press the key firmly in that same direction.
  • Page 3 (see Step 4 Diagram). NOTE: the bottle Step 2 Diagram filler will work only if a filter cartridge is installed and its wiring is plugged in (see Step 7). Step 4 Diagram (Back View) 08/17 Model 2000SMS/2000SMSN Page 3 of 5...
  • Page 4 1/8” x 3” zinc-plated steel toggle bolts (not supplied) in conjunction with six appropriately-sized zinc-plated steel 1/8” fender washers (not supplied). Use a level to verify horizontal and vertical frame mounting. Steps 5 & 6 Diagram 08/17 Model 2000SMS/2000SMSN Page 4 of 5...
  • Page 5 (both of these are normal occurrences after a filter change). Check the system for leaks. Place hex key in a secure location. 08/17 Model 2000SMS/2000SMSN Page 5 of 5...