STONEFLY ISC-808S Setup Manual

Storage area network (san), appliance

Advertisement

Quick Links

Setup Guide
ISC - Storage Area Network (SAN)
Appliance
ISC-808S 8-bay / 2U Model
www.stonefly.com
www.iscsi.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ISC-808S and is the answer not in the manual?

Questions and answers

Summary of Contents for STONEFLY ISC-808S

  • Page 1 Setup Guide ISC - Storage Area Network (SAN) Appliance ISC-808S 8-bay / 2U Model www.stonefly.com www.iscsi.com...
  • Page 2 This Page is intentionally left blank.
  • Page 3 All rights are reserved. No part of this document may be photocopied or reproduced without the prior written consent of StoneFly. The information contained in this document is subject to change without notice. StoneFly shall not be liable for errors contained herein or for consequential damages in connection with the furnishing, performance, or use of this material.
  • Page 4: Table Of Contents

    : ..........37 TEPS TO OMPLETE EFORE ETTING P THE YSTEM 3.1.11 ............37 TTACHING AND EMOVING THE RONT EZEL 3.1.12 ) ......... 38 ONNECTING TO XTERNAL TORAGE ESOURCES PTIONAL V8.0.3x © StoneFly Inc. | All rights reserved Page 3...
  • Page 5 StoneFly ISC Setup Guide Introduction Chapter-1: Introduction V8.0.3x © StoneFly Inc. | All rights reserved Page 4...
  • Page 6: Introduction

    This guide provides the information needed to perform the out-of-the-box setup and configuration tasks for the StoneFly ISC™ storage appliance. After completing the steps in this guide, proceed to the StoneFly Storage Concentrator User’s Guide. Refer to “Chapter 2 – Administrative Interface” for information on how to efficiently and effectively manage data storage, data protection, and data delivery on your network.
  • Page 7 StoneFly ISC Setup Guide Overview Chapter-2: Overview V8.0.3x © StoneFly Inc. | All rights reserved Page 6...
  • Page 8: Product Overview

    Figure 1: ISC-808s 8-Bay Model (without bezel) StoneFly ISC comes in four standard configurations: •...
  • Page 9: Isc Features And Benefits

    • Maximizes utilization of storage resources Responds to changes quickly • Mirroring Supports both local and remote, synchronous and asynchronous mirroring with StoneFly Reflection™ and StoneFly Replicator(R) CDP software Disk-to-Disk backup • Simultaneous backup streams from multiple servers for faster, more reliable backups.
  • Page 10 • Access local and remote copies of user configuration data Object storage resources Integrated cloud connection to Microsoft Azure Blob • Storage, Amazon AWS S3 and/or compatible AWS S3 storage V8.0.3x © StoneFly Inc. | All rights reserved Page 9...
  • Page 11: Theory Of Operation

    2.2. Theory of Operation The StoneFly ISC is the mediator between hosts and storage devices in an IP network. IP-based Storage Area Networks (IP SANs) use the iSCSI protocol over an Ethernet and TCP/IP network. ISC also offers Network Attached Storage (NAS) which allows multiple host/users share files over an Ethernet network.
  • Page 12: Installation

    Ethernet switch. 4. Set up the IP network so that the Management port is on a different subnet than the main network. 5. Configure the ISC and provision your storage volumes. V8.0.3x © StoneFly Inc. | All rights reserved Page 11...
  • Page 13 7. Connect the servers to the Gigabit Ethernet switch. 8. Set up the initiators on the servers to recognize the provisioned storage volumes and configuring security settings. Figure 2: A typical configuration of ISC V8.0.3x © StoneFly Inc. | All rights reserved Page 12...
  • Page 14: Safety Information

    CE Mark (EN 455022, Class A/EN 455024) Product Registration To initiate StoneFly customer service for your product, you must first register your ISC. Go to the StoneFly web site at: www.stonefly.com/support/register.asp or mail in the registration card that was included with your ISC.
  • Page 15: Contacting Stonefly For Help

    Initiators: ____________________________ Storage: _____________________________ Storage Serial Number(s): _______________ To contact StoneFly, call 510.265.1616 and select support from the menu or go to the StoneFly support page at https://www.stonefly.com/support and fill out the contact form. V8.0.3x © StoneFly Inc. | All rights reserved...
  • Page 16 StoneFly ISC Setup Guide Initial Installation Chapter-3: Initial Installation V8.0.3x © StoneFly Inc. | All rights reserved Page 15...
  • Page 17: Setting Up The Isc

    • A StoneFusion Operating System CD for system recovery 3.1.2 Rack Installation Instructions This section provides information on installing the StoneFly ISC appliance into a rack or cabinet with the rails provided. There are a variety of rack/cabinet units on the market, which may mean that the assembly procedure will differ slightly.
  • Page 18 1. Pull the inner rail out of the outer rail until it is fully extended as illustrated below. 2. Press the locking tab down to release the inner rail. 3. Pull the inner rail all the way out. 4. Repeat for the other outer rail. V8.0.3x © StoneFly Inc. | All rights reserved Page 17...
  • Page 19 4. Optionally, you can further secure the inner rail to the chassis with a screw. 5. Repeat for the other inner rail. V8.0.3x © StoneFly Inc. | All rights reserved Page 18...
  • Page 20 StoneFly ISC Setup Guide Initial Installation Figure 5: Installing the Inner Rails Figure 6: Inner Rails Installed on the Chassis V8.0.3x © StoneFly Inc. | All rights reserved Page 19...
  • Page 21 Failure to stabilize the rack can cause the rack to tip over. Do not use a two post “telco” type rack. V8.0.3x © StoneFly Inc. | All rights reserved Page 20...
  • Page 22 Note: The figure above is for illustrative purposes only. Always install servers to the bottom of the rack first. Caution: Do not pick up the server with the front handles. They are designed to pull the system from a rack only. V8.0.3x © StoneFly Inc. | All rights reserved Page 21...
  • Page 23: Onfiguring The Etwork Ettings

    It is also possible to use a laptop PC that is directly connected to the Management Port. It is also possible to use a serial cable and a console login. See the Service Menu section of the User’s Guide for complete details. V8.0.3x © StoneFly Inc. | All rights reserved Page 22...
  • Page 24: Abling The Ystem

    StoneFly ISC Setup Guide Initial Installation 3.1.5 Cabling the System To cable the StoneFly ISC system, follow these steps: Configure a PC and the ISC as described in the section 3.1.4. Refer to the MGMT port indicator in the following picture.
  • Page 25: Configuring The Network Settings For The Isc Management Port

    At the password prompt type coni100o and hit Enter. Note that the User ID and password are case sensitive. Using the Storage Concentrator Service menu, enter 2 to select Network. V8.0.3x © StoneFly Inc. | All rights reserved Page 24...
  • Page 26: Configuring The Network Settings For The Ipmi Kvm

    GUI becomes available once the CLI is closed. At this point, it should be possible to login to the web GUI for the StoneFly ISC appliance by browing to the management IP address that you just configured in the last step. Once logged in, you should configure the SAN data network settings.
  • Page 27 On the BIOS screen, navigate to the Advanced tab and select IPMI Configuration. The IPMI configuration screen will be displayed. Select Set LAN Configuration. The network settings will be displayed V8.0.3x © StoneFly Inc. | All rights reserved Page 26...
  • Page 28 Same as the ISC’s Management port Update LAN Settings Press the F10 key to save the changes and exit. Note: Power cycle the system for the new IPMI IP Address to take effect. V8.0.3x © StoneFly Inc. | All rights reserved Page 27...
  • Page 29 IP address you configured in the last section. Enter the following information in the login screen: Username: ADMIN • Password: ADMIN • Select the Remote Control tab to access the system console. V8.0.3x © StoneFly Inc. | All rights reserved Page 28...
  • Page 30 StoneFly ISC Setup Guide Initial Installation Select Launch Console to open the system console. The console screen will appear as shown above. V8.0.3x © StoneFly Inc. | All rights reserved Page 29...
  • Page 31: Stonefusion™ Software Configuration

    Initial Installation 3.1.6 StoneFusion™ Software Configuration StoneFly ISC comes pre-installed with StoneFly’s Software Defined Storage (SDS) solution: StoneFusion. This section describes the configuration process for the StoneFusion software. Figure 10: StoneFusion Login Screen 6. In the User ID field type: admin 7.
  • Page 32 Password and directory. Select Passive or Non Passive and click Submit. Both methods can be used, but at least one should be configured to ensure recovery if needed. 13. Navigate to Admin > General. The System Admin screen will appear. V8.0.3x © StoneFly Inc. | All rights reserved Page 31...
  • Page 33 16. Click Submit. 17. Navigate to Network > Data Port. The Local iSCSI Data Port Settings screen appears with the current system (factory) settings. Most fields are blank. V8.0.3x © StoneFly Inc. | All rights reserved Page 32...
  • Page 34 Concentrator. Navigate to the System > Admin > General screen and click on Reboot. If no changes are desired continue to the next step to configure the Management Port. 23. Click on Management Port. The Management Port Settings screen appears. V8.0.3x © StoneFly Inc. | All rights reserved Page 33...
  • Page 35 Depending on the speed of your browser connection, you may not see this screen. Your changes will still take effect, however you will need to manually set your browser’s URL to point to the new IP address. V8.0.3x © StoneFly Inc. | All rights reserved Page 34...
  • Page 36: Setting Up Routing

    Host GbE Port Settings screen. For example, if the ISC network setting is 26.34.128.50 and the host network setting is 106.39.212.6, a route to the host must be configured. V8.0.3x © StoneFly Inc. | All rights reserved Page 35...
  • Page 37: Confirming Setup

    Launch your web browser. In the URL address field, type the IP address you set up for the Management GbE port during the configuration process. Be sure to include https:// in the address. V8.0.3x © StoneFly Inc. | All rights reserved Page 36...
  • Page 38: Steps To Complete Before Setting Up The System

    SAN disconnections. 3.1.11 Attaching and Removing the Front Bezel Follow the below steps when attaching or removing the front bezel of the StoneFly ISC: Attach the front bezel after initial installation is completed. This will help prevent •...
  • Page 39: Connecting To External Storage Resources (Optional)

    SAS Extension (Optional) Figure 17: Back Panel of ISC StoneFly ISC appliances have an option for connecting additional storage devices using external SAS expansion units. SAS Expansion The standard ISC has an internal SAS RAID controller. The technology allows for an additional port on the rear apron of the RAID controller.
  • Page 40 StoneFly ISC Setup Guide Troubleshooting Chapter-4: Troubleshooting V8.0.3x © StoneFly Inc. | All rights reserved Page 39...
  • Page 41 StoneFly ISC Setup Guide Troubleshooting Refer to the following table for helpful hints on solving some of the most common problems. If you cannot find a resolution to your problem here, contact StoneFly. Call 510.265.1616 and select support from the menu. Problem...
  • Page 42 Type the IP address for the Management Port of the Storage Concentrator in the address field of the browser. The address field in the browser must include https:// to access the administrative interface. V8.0.3x © StoneFly Inc. | All rights reserved Page 41...
  • Page 43 StoneFly ISC Setup Guide Troubleshooting This Page is intentionally left blank. V8.0.3x © StoneFly Inc. | All rights reserved Page 42...
  • Page 44 StoneFly ISC Setup Guide Glossary Appendix-1: Glossary V8.0.3x © StoneFly Inc. | All rights reserved Page 43...
  • Page 45 Asynchronous I/O Operation An I/O operation whose initiator does not await its completion before proceeding with other work. Asynchronous I/O operations enable an initiator to have multiple concurrent I/O operations in progress. V8.0.3x © StoneFly Inc. | All rights reserved Page 44...
  • Page 46 Assignment of the operating parameters of a system, subsystem, or device. For example, disk array configuration includes designating the member disks or extents for the array, as well as setting parameters such as stripe depth, RAID model, and cache allowance. V8.0.3x © StoneFly Inc. | All rights reserved Page 45...
  • Page 47 When it runs on a disk controller, control software is often called firmware or microcode. Control software that runs on a host computer is usually called a volume manager. V8.0.3x © StoneFly Inc. | All rights reserved Page 46...
  • Page 48 (files). File systems are often supplied as operating system components but are implemented and marketed as independent software components. Graphical User Interface (GUI) A user interface for intelligent devices that is characterized by pictorial displays and highly structured forms-oriented input. V8.0.3x © StoneFly Inc. | All rights reserved Page 47...
  • Page 49 SCSI command set, the core command set used in all storage configurations. iSCSI Client A logical entity, typically a host, which includes at least one iSCSI Initiator. V8.0.3x © StoneFly Inc. | All rights reserved Page 48...
  • Page 50 Logical Partition Logical Unit A logical partition is a segmentation of a logical volume. Logical Unit Number (LUN) The entity within a SCSI target that executes I/O commands. SCSI I/O commands are sent V8.0.3x © StoneFly Inc. | All rights reserved Page 49...
  • Page 51 In file systems, meta-data includes file names, file properties and security information, and lists of block addresses at which each file’s data is stored. Mirroring V8.0.3x © StoneFly Inc. | All rights reserved Page 50...
  • Page 52 Mirror Volume A Mirror Volume is composed of multiple mirror images. StoneFly Mirroring supports up to four mirror images in a mirror volume. The Mirror Volume is what the applications and hosts see as the storage device.
  • Page 53 It can also be useful administratively, for example, to create hard subdivisions of a large logical disk. Path The access path from a host computer to a storage device. V8.0.3x © StoneFly Inc. | All rights reserved Page 52...
  • Page 54 A unit of storage space on a physical device containing a specific amount of storage space. A collection of physical extents is then managed by the StoneFly Volume Manager as a logical volume, and a group of logical volumes make up a volume group. Physical extents are the smallest manageable element in a logical volume that can be managed by the StoneFly Volume Manager.
  • Page 55 “good” data point in the event of corruption, viruses, or lost files. Essentially, performing a rollback returns the Live Volume to the last good known state. Scalability Capable of being changed in size and configuration. It typically refers to a computer, V8.0.3x © StoneFly Inc. | All rights reserved Page 54...
  • Page 56 These percentages represent the amount of the index table fragmentation on the volume selected as well as the total amount of fragmentation for all Snapshot volumes. These percentages have no relationship to disk fragmentation. V8.0.3x © StoneFly Inc. | All rights reserved Page 55...
  • Page 57 SCSI connection or other connections. The system administrator uses the graphical user interface to allocate blocks of storage to create the iSCSI target volumes and authorizes their use by individual host systems. V8.0.3x © StoneFly Inc. | All rights reserved Page 56...
  • Page 58 A Volume group is a management abstraction term. For example, management actions and policies are applied to volume groups. V8.0.3x © StoneFly Inc. | All rights reserved Page 57...
  • Page 59 Eden Landing Road, Hayward, CA 94545, USA. (510) 265 1616 support@stonefly.com...

Table of Contents