Samsung DVE45T3200 Series User Manual page 25

Hide thumbs Also See for DVE45T3200 Series:
Table of Contents

Advertisement

Available languages

Available languages

STEP 3 Connect the electrical wiring
First, read through the "Electrical requirements" section, and follow these steps.
3-wire system
A
B
C
L2
A. External ground connector
B. Neutral grounding wire (white)
C. Center silver-colored terminal block
screw
D. Neutral wire (white or center wire)
E.
/
" (1.9 cm) UL-listed strain relief
3
4
DV3200T_DC68-03784N-00_EN.indd 25
1. Loosen or remove the screws from the
2. Connect the neutral wire (white or
3. Connect the other wires to outer
D
4. Tighten the strain relief screws.
L1
5. Insert the terminal block cover into the
E
• To convert from the 4-wire system
• Ring-type terminals are recommended.
• Before Installing the Dryer, confirm
center terminal block.
center wire) of the power cable to the
center, silver-colored terminal screw of
the terminal block. Tighten the screws.
terminal block screws. Tighten the
screws.
rear panel of the dryer. Then, secure the
cover with a hold-down screw.
CAUTION
to 3-wire system, connect the ground
strap to the terminal block support to
ground the dryer frame to the neutral
conductor.
If using strap terminals, make sure they
are tightened.
240V is present between L1 and L2 at
the power receptacle. If the Voltage is
low, it may not dry properly. Review
the "Electrical requirements" section on
page 19 if needed.
English 25
2020-05-25
11:10:20

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dvg45t3200 series

Table of Contents