MidgeaterPlus™ is used for its designed purpose only. Before putting the MidgeaterPlus™ into use for the first time, please familiarise yourself with the contents of this instruction booklet. Due to ongoing improvements of the product the information contained in...
2. Safety Precautions • The MidgeaterPlus™ is designed for outdoor use only. • The MidgeaterPlus™ should only be used for insect capture. • Carefully supervise children and animals when the MidgeaterPlus™ is in use. • Please remember there are no “safe slopes”. Position the MidgeaterPlus™...
Page 5
ORIGINAL SPARE PARTS are not used as replacement parts. c) this product has been safety tested as is, any alterations to the MidgeaterPlus™ will nullify your warranty. Precautions for Handling Bait Sachet The bait is harmful if swallowed, absorbed through skin or inhaled.
3. Operating Instructions 1. Place MidgeaterPlus™ in desired position on level ground. Remove Cap Place Bait Replace Cap 2. The bait/attractant should then be placed in the bait holder, ensuring that the bait holder cap is replaced. 3. Connect the click/on regulator to patio gas bottle.
Page 7
13. Your MidgeaterPlus™ should now be operational. A 13kg patio gas bottle should last 24 to 28 days. This only applies if the MidgeaterPlus™ is left to run continuously, for which purpose it has been designed and tested. Continuous use is recommended for best results.
MidgeaterPlus™ before they reach the people. It may be worth trying several locations to identify which is the most effective for your MidgeaterPlus™. Furthermore, changes in wind direction could alter the midges’ behaviour so it may be necessary to move the trap from one location to another throughout the season.
5. Trouble-Shooting Guide Below is a list of problems that we believe that our customers may be able to solve themselves when the unit fails to operate correctly. If you are unsure about carrying out any of these tasks, please call our technical help line (01382 618444) for assistance.
Page 10
** NEVER TRY TO IGNITE THE MIDGEATER WHEN THE SERVICE PANEL ** IS REMOVED AS IN FIG 2. STEP 5 If the problem persists a Texol engineer should be called to rectify the fault. NOZZLE HOUSING BLOCKAGE: Assuming that the regulator is fitted properly and the igniter is sparking, the next check is the Nozzle Housing.
Page 11
If the fan is working, the MidgeaterPlus™ can still be used even though the power gauge is not operational. A new gauge can be ordered by calling the helpline.
Page 12
MIDGEATER CUTTING OUT: Your MidgeaterPlus™ is operational but after a short period of time the MidgeaterPlus™ cuts out. This fault may be caused by a problem with the bi-metallic switch which is located on the engine. A new switch can be ordered by calling the helpline.
6. Cleaning Instructions Tools required for cleaning are, a Philips screwdriver and a vacuum cleaner with crevice attachment. 1. Remove midge capture bag 2. Clean midge capture chamber with a damp cloth or vacuum cleaner 3. Remove service panel by removing 4 screws as per Fig 6. 4.
8. Winter Storage Instructions We strongly recommend that your MidgeaterPlus™ is thoroughly cleaned as per the cleaning instructions previous and also by using the supplied winter kit (contact helpline if winter kit is required) before winter storage. By following the instructions below, this should help to prevent any future problems arising on start-up next season.
9. Frequently Asked Questions. Q. How does the MidgeaterPlus™ work? A. The MidgeaterPlus™ draws insects towards it by emitting a plume of harmless carbon dioxide. This is produced as a by-product of burning propane through catalytic conversion, which also produces warmth and moisture.
Page 18
The dead midge can then be disposed of at your discretion. Q. My MidgeaterPlus™ has caught plenty of midge but there are still plenty in other parts of the garden. A. The MidgeaterPlus™ is designed to be moved around. You may have to try several locations before you identify the best position for your MidgeaterPlus™.
As a valued customer and someone who we hope is benefiting from the use of our Midgeater product, Texol services has put together an offer of extended warranty which we are sure will be of interest to you.
Page 20
Should you wish to proceed with this offer of extended warranty please contact a member of staff at Texol. Ph – 01382 618444. Please have proof of MidgeaterPlus purchase at hand when you call as this is a necessary requirement to enable purchase of extended warranty.
11. Spare Parts List Please find below a list of parts that can be ordered by calling the helpline (01382 618444). For the self assembly of parts, this is only a recommendation. If you require a service engineer to fit the parts, call the helpline.
12. Technical Data Gas Type : Propane I Gas supply pressure : 30, 37, 50mbar Nominal Heat Input : 0.25kW Height : 1.10m Width : 520mm Weight : Approx. 30kg (without gas cylinder) Colour : Green RAL6020 Direct Countries of Destination : GB &...
13.Contact Detail Manufactured by Texol Products Ltd Myrekirk Road, Dundee, Scotland, DD2 4SX. Midgeater® is a registered trade mark. Patent Applied For : No. 0306538.0 For stockists of replacement bags & bait tablets call 01698 740660. To order Calor Patio Gas call 0800 626 626 or visit www.midgeater.co.uk...
Need help?
Do you have a question about the MidgeaterPlus and is the answer not in the manual?
Questions and answers