This equipment benefits from the latest technological innovations concerning soundproofing. To benefit fully from the advantages provided by this new generation of appliances, it is important to comply with the installation instructions in section 5. Please also see “10 golden rules” for correct Saniflo installation on www.saniflo.co.uk 2. List of Accessories included...
Page 2
Installed and used correctly, this unit will give consistent and reliable service. You can find the technical data in step 9. 4. Performance Curve & Height and Length of the discharge pipe ø The discharge pipe size for Sanitop can be 22mm or 32mm. EN 12050-3 litre/min 5m max...
WARNING! There should be no water dripping from the WC cistern or any other sanitary appliances. If there is, this will cause the unit to activate repeatedly as it pumps the water away. The Sanitop unit and all its connections should be easily accessible for possible maintenance / removal.
Page 4
7. Connections of extra sanitary appliances See figs 1 and 2 for connections that may be required for sanitary appliances. 8. Connection of discharge pipework Insert the discharge elbow (A) into the rubber discharge pipe which rises up through the lid, turn to the desired direction and secure with the metal hose clip provided (32-50mm) (B).
Page 5
9. Technical advice for discharge pipework Vertical before horizontal Air Admittance Valve Horizontal pipe runs must have a minimum fall of 1:100 (10mm per metre) to the soil stack. If a vertical lift is required, it must be made before the horizontal run at the start of the piperun. We would recommend that a drain-off point is installed to allow the discharge pipework to be drained down before any service work.
Page 6
220/240V single phase AC 50 Hz supply (UK specification). Do not connect the Sanitop to a conventional plug and socket. It must be wired into a fused, unswitched, fixed wiring connector fitted with a 5 amp fuse. The Sanitop has an earth wire. The wires in the mains lead are coloured in accordance with the following code: Brown –...
Page 7
15. Maintenance DISCONNECT THE ELECTRICAL POWER SUPPLY, BEFORE ATTEMPTING ANY WORK ON THE UNIT. No need of any particular maintenance. This unit is fitted with an active carbon filter, and requires no external venting. This filter has to be changed every year. 16.
Page 8
17. Removal DISCONNECT THE ELECTRICAL POWER SUPPLY BEFORE ANY SERVICE REMOVING THE UNIT FROM THE WC SUITE Disconnect the electrical power supply. Turn off the water feed to the WC cistern. Bail out as much water as possible from the cistern. Drain down any vertical discharge pipework and remove discharge hose from elbow.