SUMMARY Introduction Safety instructions Conditions of use Presentation and features Dimensions Description Installation instructions Installation method using truss hooks DMX512 connection Control Panel Ghibli control panel menu - Option details Master/Slave Mode settings DMX Chart Error Messages Care and maintenance Technical Specifications Warranty USER MANUAL...
Anyone involved in installing, operating or servicing the KHAMSIN must: At first use, your KHAMSIN may give off an odor. This is a normal • Be a qualified, authorized professional occurrence that should dissipate after a few minutes of operation.
Do not shake the KHAMSIN while installing or handling. the luminaire from the power source. Do not pull the KHAMSIN by one of its cables to move it. Lift the luminaire Never dispose of the KHAMSIN in a rubbish bin. Ensure that it is recycled.
DESCRIPTION INSTALLATION INSTRUCTIONS During installation please observe the instructions according to GB7000.15 / EN60598-2-17 standards and other national standards applicable. This luminaire should be installed by a qualified technician. The fixture should be used in an environment with a temperature between -5°C and +45°C.
ART-NET configuration with universe being used and specify luminaires to this same DMX line in a daisy chain. The DMX cable must in the menu that the KHAMSIN is being controlled through ART-NET (see be a shielded twisted pair that is equipped with male and female XLR OPTION DETAILS in the «...
THE KHAMSIN DMX ADDRESS SETTING Table 1: KHAMSIN MENU FUNCTIONS AND OPTIONS All luminaires must have a DMX start address correctly set when using a Address Address DMX address:001-XXX: DMX address setting DMX signal to control them. The DMX start address is the channel from...
Page 10
KHAMSIN CONTROL PANEL MENU – OPTION DETAILS w Long click to exit the menu –“Status” then back to main menu by long click again. The following section provides details on the options that can be selected Pan Reverse through the control panel menu. Refer to the table above.
Page 11
w Double click to access to access “Pan/Tilt Spd” The display will show w Double click to confirm “Speed 1” Turn the jog wheel to select “Speed 1” “Speed 2” “Speed 3” w Long click to exit menu –“Service PIN” then back to main menu by Long or “Speed 4”.
Page 12
TEMP. C/F w Double click to confirm w Long click the jog wheel to back to last button press –“Display Setting” Allows you to select the unit of measurement for the temperature values, then back to main menu by long click again in either Celsius or Fahrenheit.
Page 13
Auto Program Timer PIN Allows you to run an internal program (a sequence of scenes) by selecting The “Timer PIN” is the password required to reset the counter for “Last whether the fixture is operating alone or as a master. Run Hrs.”...
MASTER/SLAVE MODE SETTINGS TEST HOME Allows you to reset the functions. You can select these functions by A MASTER fixture can send up to 3 different sets of data to a SLAVE adjusting the channel. fixture (e.g., a MASTER fixture can control 3 different SLAVE fixtures which w Double click jog wheel to access main menu.
DMX CHART amount: 250 scenes) Press ENTER to confirm. THE following chart shows the functions and corresponding values for Press MODE/ESC to return to the main menu. each DMX channel according to mode whether Standard (St), Basic (Ba) or Extended (Ex): Example: ”Program 2”...
Page 16
DMX channel´s functions and their values (64DMX channels): DMX channel´s functions and their values (64DMX channels): Mode/Channel Value Function Mode/Channel Value Function Zoom Fine: Rotating gobos, cont. rotation 1: 0-255 Zoom adjustment Fine Open Focus : 10-23 Rot. gobo 1 0-255 Continuous adjustment from near to far 24-37...
Page 17
DMX channel´s functions and their values (64DMX channels): DMX channel´s functions and their values (64DMX channels): Mode/Channel Value Function Mode/Channel Value Function Iris: Blade 4 A Fine: 0-191 0-255 Open to Close Fine Max. diameter to Min.diameter 192-223 Pulse closing fast to slow Blade 4 B : 224-255 Pulse opening slow to fast...
CLEANING Your KHAMSIN requires cleaning at regular intervals. Be aware that When you turn on the KHAMSIN, it will first perform an automatic reset. accumulated dust and residue on the air vents, body and glass of the The display may show “Err channel is XX” indicating there is a problem fixture may reduce efficiency and impair proper operation.
• Full menus for setting DMX address and advanced functions • Compatible with the DMX/RDM (Remote Device Management) protocol KHAMSIN is delivered in a carton packed with a dense, protective foam • Pre-programmed macro modes surrounding the fixture. This reusable protective shell is intended for a •...
Need help?
Do you have a question about the Khamsin and is the answer not in the manual?