AQUAMOTION Aqua-Flash AMH1K-3UV Instruction Sheet

Instant hot water recirculation system

Advertisement

Quick Links

----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

Installation and Operating Instructions

NSF 372 Certified
Thank you for choosing the Aqua-Flash Instant Hot Water Recirculation System by AquaMotion, Inc.
Please read and follow these step by step instructions to ensure that the system operates properly and reliably. Since the cold water supply line will be
used to return the cooling hot water to the hot water heater you will experience some warm water from the cold water line. Opening the cold water faucet
fully will flush the warm water from the cold line in a short period of time. After the Flash valve has been installed, system will need to cycle through from
hot to cool several times or overnight before normal operation is established.
Warning: This is not an anti-scald valve.

Inspection

Inspect the system components to ensure no damage has occurred to them during shipping. Avoid dropping the circulator which may get damaged if
dropped.
The Aqua-Flash includes:
AM3 AquaMotion Circulator with a built-in timer and a 10 Ft line cord.
AquaMotion Flash By-Pass Valve
3/8" x ½" x 3/8" Compression Tee
¾" NPT Female Tail Piece with 1 ½" Union Nut and Gasket
12" Long ½" x ½" Flex Hose
Installation and Operating Instructions

Tools Needed:

5/8" open end wrench
15/16" open end wrench or an adjustable crescent wrench that opens to 1"
Pipe wrench that opens to 2"

Limits

Maximum water temperature 110⁰C/230⁰F
Maximum Pressure Rating 125 psi

Pump Installation

Warning: For Indoor Use Only
Warning: Do not plug the pump in until the pump installed is complete.
1)
Shut off the cold water supply to the water heater. This may be on the cold supply line above the tank or located where the water line enters
the residence.
2)
Open a hot water faucet in the residence and allow the water to run until it stops. Leave the faucet open until the installation has been
completed.
3)
Remove the hot water line from the hot water heater at the threaded outlet pipe at the top of the tank.
Place the large union nut over the threaded outlet pipe before threading the ¾" NPT Tail Piece onto the threaded outlet pipe.
4)
5)
Place the union gasket on the tail piece and thread the large union nut onto the circulator.
6)
Reconnect the hot water line that was removed in step 3 to the circulator.
hoses are used at this connection, then no pipe dope of Teflon Tape are required.
AquaMotion Inc. 88 C Jefferson Blvd., Warwick, RI 02888 Tel: 401-785-3000 Fax: 401-785-3033
Copyright 2017 – AquaMotion Inc.
Printed in USA
Instruction Sheet for Aqua-Flash
Instant Hot Water Recirculation System
Kit No. AMH1K-3UV & RS100 & RS101
Fig. 1.
Fig. 3.
Fig. 2.
Use pipe dope or Teflon Tape to seal the threads. If flex
Effective 6/30/17
IS-AM09-597
Fig. 1.
Fig. 2.
Page 1 of 2

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Aqua-Flash AMH1K-3UV and is the answer not in the manual?

Questions and answers

Summary of Contents for AQUAMOTION Aqua-Flash AMH1K-3UV

  • Page 1 NSF 372 Certified Thank you for choosing the Aqua-Flash Instant Hot Water Recirculation System by AquaMotion, Inc. Please read and follow these step by step instructions to ensure that the system operates properly and reliably. Since the cold water supply line will be used to return the cooling hot water to the hot water heater you will experience some warm water from the cold water line.
  • Page 2 Instruction Sheet IS-AM09-597 6/30/17 Fig. 3. Fig. 4. Reopen the cold water supply valve to the hot water heater. Allow the water to run at the faucet to purge the air from the lines. Close the faucet. Plug in the circulator into a properly grounded 115V outlet. Valve Installation Note: Pipe dope and Teflon tape are not required for any of the valve threads.

This manual is also suitable for:

Aqua-flash rs100Aqua-flash rs101

Table of Contents