8.5.
noZZlE (See fig.7)
The nozzle should be cleaned at least once per heating season. Use of contaminated fuel will make it necessary to clean the nozzle
more frequently. To clean dirt from the nozzle, blow compressed air through the front of the nozzle. It may be necessary to soak the
nozzle in paraffin, kerosene first in order to loosen any dirt particles.
8.6.
SPARk PlUG (See fig.8)
Clean and re-gap the spark plug every 600 hours of operation, or replace if needed. After removing the spark plug, clean the terminals
with a wire brush. Re-gap the terminals to 3.5mm (0.140").
8.7.
PHoTo CEll (See figs.9&10)
The photocell should be cleaned at least once per heating season or more depending on conditions of use. Use a cotton swab dipped in
water or alcohol to clean the lens of the photocell. The positioning of the photocell is critical to its correct operation. See fig.10 for the
correct installation.
8.8.
fUEl filTER (See fig.11)
The fuel filter should be cleaned at least twice per heating season by rinsing it in clean paraffin or kerosene. Use of contaminated fuel
will make it necessary to clean the filter more frequently. To remove the filter first squeeze the legs of the fuel line clip and move it up the
fuel line. ease the fuel line from off the filter head. Turn the hexagonal head of the filter 90° anti-clockwise and ease it upwards and out
of the tank.
fig.9
8.9.
fUSE REPlACEMEnT (See fig.12)
noTE:
This is a fuse protected heater.
If your heater fails to ignite check the fuse as shown in fig.12 before contacting your local
service agent.
WARninG! Unplug the heater from the mains power supply before attempting any
maintenance work.
8.9.1.
Remove the control panel screws using a medium phillips screwdriver and lift off the side
panel to reveal the printed circuit board.
8.9.2.
Remove fuse from holder as shown below.
8.9.3.
Replace fuse with one of the same specification.
WARninG! do not substitute the fuse with one of a higher or lower current rating as this
may result in a fire hazard.
8.9.4.
Replace side panel.
8.10.
lonG TERM SToRAGE
If the heater is to be stored for a long period of time, drain the fuel through the fuel cap
opening. Rinse and swirl a small amount of fuel within the tank and then empty it fully.
When you come to use the heater again do not use old fuel which has been stored from
the previous season. Use of old fuel can damage your heater.
Although our heaters operate with diesel fuel, when the temperature is below
0°C diesel additives are required to maintain the diesel's viscosity. Typically
diesel can cloud in freezing conditions and will start to gel. You will need
additives for your fuel in these conditions. Kerosene/Paraffin does not start
to gel until the ambient temperature is around -40°C .