Installation distances and measurements (mm)

If a hood is installed above the hob, read the instructions for fitting the hood where it indicates the correct
distances to be complied with.
Note: If the distance "A" between the kitchen wall cabinets is between 600 and 730 mm, height "B" shall
be at least 530 mm.
If the distance "A" between the kitchen wall cabinets is wider than the hob's width, height "B" shall be at
least 400 mm.

Injectors table

Category II2H3+
Type of gas used
Type of
burner
NATURAL GAS
wok
(Methane) G20
semi-fast
auxiliary
LIQUID
wok
PETROLEUM GAS
semi-fast
(Butane) G30
auxiliary
LIQUID
wok
PETROLEUM GAS
semi-fast
(Propane) G31
auxiliary
Type of gas used
G20 20 mbar
G30 28-30 mbar
G31 37 mbar
Electric Power: 230 V - 50 Hz
181,6
22
16
274
Injector
Control primary
label
air (X) mm
145
6
95
-
78
-
95
11
67
-
50
-
95
11
67
-
50
-
Configuration
model
4 burners
4 burners
4 burners
Nominal heat
flow kW
consumption
4,20
1,65
1,00
3,80
1,65
1,00
3,80
1,65
1,00
Nominal heat
Overall nominal
flow kW
8,5
8,1
8,1
7
Nominal
Reduced heat
flow kW
400 l/h
1,50
157 l/h
0,35
95 l/h
0,30
276 g/h
1,50
120 g/h
0,35
73 g/h
0,30
272 g/h
1,50
118 g/h
0,35
71 g/h
0,30
consumption
for the combustion 1 m
809 l/h
589 g/h
579 g/h
Gas pressure (mbar)
min.
nom.
max
17
20
25
20
28-30
35
25
37
45
Required air (m
3
)
3
of gas
9,52
30,94