ESD attacks with industrial-grade shielded Ethernet cable from Ubiquiti Networks. For more details, visit www.ubnt.com/toughcable TERMS OF USE: Ubiquiti radio devices must be professionally installed. Shielded Ethernet cable and earth grounding must be used as conditions of product warranty. TOUGHCable ™...
Hardware Overview RP-SMA Antenna Connectors LED Panel Port Cover...
Page 4
LED Panel Vertical Row Signal In airOS, you can modify the wireless signal strength threshold values for each LED on the Advanced tab under Signal LED Thresholds. The default values are shown below: LED will light blue when the wireless signal strength is above -65 dBm.
Page 5
Ports Reset Button RESET LAN Port LAN/PoE The Gigabit Ethernet port is used to connect the power and should be connected to the LAN. Reset Button To reset to factory defaults, press and hold the Reset button for more than 10 seconds while the Rocket is already powered on.
Hardware Installation The Rocket5ac PtMP is designed to mount directly onto a Ubiquiti airMAX Sector Antenna. 1. Press down on the Port Cover of the Rocket and slide it off. 2. Connect an Ethernet cable to the LAN port. RESET 3.
Page 7
4. Connect the RF cables to the RP-SMA Connectors located on top of the Rocket. 5. Attach the Rocket to the sector antenna. a. Align the mounting tabs on the back of the Rocket with the four mounting slots on the sector antenna. b.
Page 8
6. Attach the other ends of the RF Cables to the RF connectors in this combination: Chain 1 to V and Chain 0 to H. 7. Slide the Protective Shroud over the Rocket until it locks into place on the Sector Antenna.
Connecting Power over Ethernet 1. Connect the other end of the Ethernet cable from the Rocket to the Ethernet port labeled POE on the Gigabit PoE Adapter. 2. Connect an Ethernet cable from your LAN to the Ethernet port labeled LAN on the Gigabit PoE Adapter. 3.
Page 10
Accessing airOS Connect to the airOS Configuration Interface. 1. Make sure that your host machine is connected via Ethernet to the Rocket. 2. Configure the Ethernet adapter on your host system with a static IP address on the 192.168.1.x subnet. 3.
Since Ubiquiti Networks equipment can be paired with a variety of antennas and cables, the Antenna Gain, Cable Loss, and Output Power fields are provided to the professional...
Safety Notices Read, follow, and keep these instructions. Heed all warnings. Only use attachments/accessories specified by the manufacturer. WARNING: Do not use this product in location that can be submerged by water. WARNING: Avoid using this product during an electrical storm.
Ubiquiti MAC label, or is missing any other original Ubiquiti label(s); or (VII) has not been received by Ubiquiti within 30 days of issuance of the RMA. In addition, the above warranty shall apply only if: the product has been properly installed and used at all times in accordance, and in all material respects, with the applicable Product documentation;...
Page 15
No Products will be accepted for replacement or repair without obtaining a Return Materials Authorization (RMA) number from UBIQUITI NETWORKS during the warranty period, and the Products being received at UBIQUITI NETWORKS’ facility freight prepaid in accordance with the RMA process of UBIQUITI NETWORKS.
Limitation of Liability EXCEPT TO THE EXTENT PROHIBITED BY LOCAL LAW, IN NO EVENT WILL UBIQUITI OR ITS SUBSIDIARIES, AFFILIATES OR SUPPLIERS BE LIABLE FOR DIRECT, SPECIAL, INCIDENTAL, CONSEQUENTIAL OR OTHER DAMAGES (INCLUDING LOST PROFIT, LOST DATA, OR DOWNTIME COSTS), ARISING...
Page 17
Compliance Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions. This device may not cause harmful interference, and This device must accept any interference received, including interference that may cause undesired operation.
Industry Canada CAN ICES-3(B)/NMB-3(B) To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that permitted for successful communication. This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: This device may not cause interference, and This device must accept any interference, including interference that...
Page 19
CAN ICES-3(B)/NMB-3(B) Pour réduire le risque d’interférence aux autres utilisateurs, le type d’antenne et son gain doivent être choisies de façon que la puissance isotrope rayonnée équivalente (PIRE) ne dépasse pas ce qui est nécessaire pour une communication réussie. Cet appareil est conforme à la norme RSS Industrie Canada exempts de licence norme(s).
CE Marking CE marking on this product represents the product is in compliance with all directives that are applicable to it. Alert Sign (!) Follows CE Marking Alert sign must be indicated if a restriction on use applied to the product and it must follow the CE marking.
Page 21
Español La Directiva 2002/96/CE de la UE exige que los equipos que lleven este símbolo en el propio aparato y/o en su embalaje no deben eliminarse junto con otros residuos urbanos no seleccionados. El símbolo indica que el producto en cuestión debe separarse de los residuos domésticos convencionales con vistas a su eliminación.
UBIQUITI NETWORKS device, megfelel a vonatkozó alapvetõ [Hungarian] követelményeknek és az 1999/5/EC irányelv egyéb elõírásainak. Íslenska Hér me l sir UBIQUITI NETWORKS yfir ví a UBIQUITI NETWORKS device, er í samræmi vi grunnkröfur og a rar kröfur, sem ger ar eru í [Icelandic] tilskipun 1999/5/EC.
NETWORKS device, è conforme ai requisiti essenziali ed alle altre [Italian] disposizioni pertinenti stabilite dalla direttiva 1999/5/CE. Latviski Ar o UBIQUITI NETWORKS deklar , ka UBIQUITI NETWORKS device, atbilst Direkt vas 1999/5/EK b tiskaj m pras b m un citiem ar to saist [Latvian] tajiem noteikumiem.