NOTICE:
◾ ◾
a significantly reduced run time after fully charging the battery pack indicates
that the batteries are near the end of their usable life and must be replaced.
◾ ◾
the charger may warm during charging. this is part of the normal operation of
the charger. charge in a well-ventilated area.
leD FunctionS oF charger (Fig. 3)
leD inDicatOr
leD On the charger
BatterY
pacK
leD1
Defective
Flashing
red or
off
cold/hot
Shining
Battery
red
charging
Flashing
green
Shining green
alternately
Shining green alternately
Shining green alternately
Full
Shining green continuously
charged
Self-main-
intermittently quick flashing in green
tenance
leD2
leD3
leD4
Off
Off
Off
Off
Off
Off
Off
Off
Off
Off
Off
Off
56V 30-minute charger — ch5500
pOWer
inDicatOr
BetterY
On the
pacK
BatterY
pOWer
pacK
Off
Off
Flash-
less
ing red,
than
orange
25%
and green
25% to
alternately
50%
50% to
75%
75% to
90%
Off
90% to
100%
Off
approx.
30%
actiOn
Battery pack
or charger is
defective.
charging will
begin when
battery pack
returns to 37°F
(3°c)–135°F
(57°c)
charging
charging
charging
charging
charging is
complete.
maintenance
charging.
Battery pack
is performing
self-mainte-
nance or in
sleep mode.
reinstall the
battery pack
on the charger
to recharge it
fully.