Stelpro SFECM series Installation Manual
Hide thumbs Also See for SFECM series:

Advertisement

installation guide
sFeCM series
electric furnace
This section must be read carefully by the installer.
The installer must also read the user's guide since it contains other important information.
For further information or to consult this guide online, please visit our website at www.stelpro.com
replacement component list included
this unit
complies with
the csa and ul
standards
This unit is approved according
to the Canadian and American
manufacturing standards.
INSSFECMI0914

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SFECM series and is the answer not in the manual?

Questions and answers

Summary of Contents for Stelpro SFECM series

  • Page 1 This section must be read carefully by the installer. The installer must also read the user’s guide since it contains other important information. For further information or to consult this guide online, please visit our website at www.stelpro.com INSSFECMI0914...
  • Page 2: Technical Drawings

    warning Before installing and operating this product, the user and/or installer must read, understand and follow these instructions and keep them handy for future reference. If these instructions are not followed, the warranty will be considered null and void and the manufacturer deems no further responsibility for this product.
  • Page 3: Specifications

    specifications eleCTRiC fuRNaCe Type volTs leNgTh (iN.) WidTh (iN.) depTh (iN.) sfeCm1021 240/208 10/7.5 44/38 32 1/2 22 1/16 sfeCm1521 240/208 15/11.2 65/56 32 1/2 22 1/16 sfeCm1821 240/208 17.5/13.2 75/66 32 1/2 22 1/16 sfeCm2021 240/208 20/15 85/74 32 1/2 22 1/16 sfeCm2321 240/208...
  • Page 4: Optional Accessories

    PLenum TemPerATure ConTroL PoTenTiomeTer The Stelpro electric furnace is equipped with a plenum temperature sensor. You can select the plenum temperature set point with a potentiometer installed on the control card. The default factory set point is 45°C (113°F). You can select the set point from a temperature range between 40°C (104°F) and 70°C (158°F).
  • Page 5 electrical connections of the furnace Note that this product must be connected by a qualified electrician according to the electrical and building codes effective in your region. for 240 vaC connection, you can use copper or aluminum wire (75°C (165°f)), except for 27.5 kw and 30 kw models where only copper wire is allowed.
  • Page 6 electrical connection of the thermostat The thermostat must be mounted to a FURNACE TO 24 V THERMOSTAT CONNECTIONS WITH HEAT PUMP connection box, at around 1.5 m (5 feet) * R terminal: 1A maximum above the floor level, on a section of the wall exempt from pipes or air ducts.
  • Page 7: Operation

    operation ConTroL PAneL 9 10 tHerMostat HigH/Haute standard sFecm low/Basse Modes LegenD 1. ConTinuous VenTiLATion button: Allows the selection of the 6. eCo moDe green LED: Indicates that the Eco mode is activated. high or low speed continuous ventilation mode. 7.
  • Page 8: Air Conditioning

    PumP If a heat pump is installed in your central heating system, the Stelpro electric furnace offers the installer two types of installations: type ”A” or type ”B”. Installation ”A” must be selected when the heat pump is installed After the furnace (air supply), and installation ”B” must be selected when the heat pump is installed Before the furnace (air return), as shown in the next picture.
  • Page 9 The heat pump can operate all year and allows the user to make energy savings due to the plenum temperature regulation function (exclusive to Stelpro). This function ensures a constant temperature into the plenum and the ducts. When it is cold, the heating capacity of the heat pump is reduced.
  • Page 10 moDes The user can select two different heating modes by pressing the button located in the middle of the control panel (item #4 in the control panel picture). The two modes affect the heating demand and the functions when used with the heat pump and the STANDARD mode described previ- ously.
  • Page 11: Airflow Settings

    airflow settings The SFECM furnace is equipped with an efficient ECM motor that can A potentiometer allowing to adjust the airflow corresponds to each maintain constant airflow regardless of the static pressure variation of these four modes. The potentiometers are located on the furnace in the ducts.
  • Page 12 TABLEAU D’AJUSTEMENT DES DÉBITS D’AIR TABLEAU D’AJUSTEMENT DES DÉBITS D’AIR AIRFLOW SETTINGS TABLE AIRFLOW SETTINGS TABLE CONT. VENT. W VENT. CONT. VENT. W VENT. MODÈLE / MODEL MODÈLE / MODEL Y VENT. Y VENT. 2321-1 2721 HIGH HIGH 1200 1150 1200 1500 1333...
  • Page 13: Preventive Maintenance

    maintenance N.B. In order for the warranty to be valid, the unit must be Air fiLTer cleaned regularly. Excessive dust or dirt accumulation can block the airflow, forcing the Cut off power supply at circuit breaker/fuse before cleaning the unit to work harder to maintain the desired temperature. Therefore, it unit.
  • Page 14: Troubleshooting

    ConTroL CArD AuToDiAgnosTiC The control card of the furnace is equipped with a pilot LED that allow easy and quick diagnostic of its essential functions. The yellow LED is located at the top right side of the control panel (item #10 of the control panel picture). The pilot LED will start to blink continuously when an electrical problem occurs.
  • Page 15 replacement component list Ref. # paRT # desCRipTioN ELF-SFE0221-1 ELEMENT ASSEMBLY SFE 2.5KW/240V/1PH 11'' LONg ELF-SFE0221-2 ELEMENT ASSEMBLY SFE 2.5KW/240V/1PH 14'' LONg ELF-SFE0521-1 ELEMENT ASSEMBLY SFE 5KW/240V/1PH 11'' LONg ELF-SFE0521-2 ELEMENT ASSEMBLY SFE 5KW/240V/1PH 14'' LONg BLo-004 SQUIRREL CAgE & BLOWER 10-8 BLO-005 SQUIRREL CAgE &...
  • Page 16: Limited Warranty

    Stelpro reserves the right to examine or to ask one of its representatives to examine the product itself or any part of it before honoring the warranty. Stelpro reserves the right to replace the entire unit, refund its purchase price or repair a defective part.