8-3 RESISTANCE SPECIFICATION OF SENSORS
TEMPERATURE
- 20 °C
- 15° C
- 10° C
- 5° C
0 °C
+ 5° C
+ 10° C
+ 15° C
+ 20° C
+ 25° C
+ 30 C
+ 40 C
+ 50 C
The resistance of the SENSOR has a ± 5% tolerance dif ference.
Measure the resistance of the SENSOR after leaving it for over 3 minutes in the measuring temperature.
This delay is necessary due to sensor response speed.
¥
Measure the F-SENSOR, SUPER FROST SENSOR, R1, R2-SENSOR after disconnect CON5 of PWB ASSY, MAIN.
RESISTANCE OF FREEZER
SENSOR
22.3 K
16.9 K
13.0 K
10.1 K
7.8 K
6.2 K
4.9 K
3.9 K
3.1 K
2.5 K
2.0 K
1.4 K
0.8 K
- 32 -
RESISTANCE OF REFRIGERATOR &
DEFROST SENSOR & ROOM SENSOR
77 K
60 K
47.3 K
38.4 K
30 K
24.1 K
19.5 K
15.9 K
13 K
11 K
8.9 K
6.2 K
4.3 K