VENTING

Vertical Venting

Maximum Vertical Height 37 FT.
Minimum Vertical Height 4 FT.
Up to eight (8) 45 Degree elbows may be used
NOTE: A vent restrictor must be installed in the
fireplace if the vertical height is more than 12 feet.
Only Simpson Duravent GS Piping (4" x 6 5/8")
May be Used on This Appliance.
Piping Clearances
Vertical Pipe
1 1/2" to Combustibles
Horizontal Pipe
2" To Combustibles—Top
1" To Combustibles—Sides
1/2" To Combustibles—Bottom