Electrolux GLMV169DB Service Manual page 37

Over the range microwave ovens
Table of Contents

Advertisement

1. Disconnect the power supply cord and remove the oven
from wall and remove outer case. (Refer to procedure of
"Removal of Oven from Wall" and "Outer case Removal")
2. Open the door and block it open.
3. Discharge high voltage capacitor.
4. Remove two (2) unit mounting screws.
5. Remove the hood duct. (Refer to the procedure of " HOOD
FAN MOTOR, HOOD DUCT AND OVEN LAMP SOCKET
REMOVAL".
6. Straighten the tab holding the thermal cut-out to the top
plate of the oven cavity.
7 . Release the thermal cut-out (cavity) from the one slit of
the oven cavity top plate.
8. Disconnect the wire leads from the thermal cut-out (cavity).
9. Now, the thermal cut-out (cavity) is free.
1. Disconnect the power supply cord, remove the oven from
wall and remove outer case (Refer to procedure of "Removal
of Oven from Wall" and "Outer case Removal".)
2. Open the door and block it open.
3. Discharge high voltage capacitor.
4. Disconnect the wire leads from the fan motor and the
chassis support.
5. Remove one (1) screw holding the hood duct to oven
cavity.
6. Release the wire leads from the hole of the hood duct.
7. Lift up the fan motor side of the hood duct.
8. Remove the two (2) screws holding the fan motor to the
hood duct.
9. Remove the fan blade from the fan motor shaft according
the following procedure.
10.Hold the edge of the rotor of the fan motor by using a pair
of groove joint pliers.
CAUTION:
* Make sure that any pieces do not enter the gap
between the rotor and the stator of the fan motor
because the rotor is easily shaven by pliers and metal
pieces may be produced.
* Do not touch the pliers to the coil of the fan motor
because the coil may be cut or injured.
* Do not disfigure the bracket by touching with the
pliers.
11.Remove the fan blade from the shaft of the fan motor by
pulling and rotating the fan blade with your hand.
THERMAL CUT-OUT (CAVITY) REMOVAL
COOLING FAN MOTOR REMOVAL
35
NOTE: When the tab is broken or turned off, use the another
tab which is fixed near the slit when the new thermal
cut-out is replaced.
Tab
Thermal
Cut-Out
Slit
Thermal
Cut-Out
Tab
12. Now, the fan blade will be free.
CAUTION:
* Do not reuse the removed fan blade because the hole
(for shaft) may be larger than normal.
13.Now, the fan motor is free.
Coil
Groove joint pliers
Stator
Gap
Bracket
Rotor
Rear View
Shaft
Axis
Stator
Rotor
INSTALLATION
1. Install the fan blade to the fan motor shaft according to the
following procedure.
GLMV169DB
GLMV169DQ
GLMV169DS
PLMV169DC
Top of Oven Cavity
Waveguide
Thermal
Cut-Out
(Cavity)
These are the positions
that should be pinched
with pliers
Side View

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Glmv169dqGlmv169dsPlmv169dc