AKDY 668 Series Universal Installation Instructions And Use & Care Manual

30" and 36" wall-mount range hood

Advertisement

30" AND 36" WALL-MOUNT RANGE HOOD
Universal Installation Instructions and Use & Care Guide
Model:
668 Series
63175
63190
IMPORTANT: READ AND SAVE THESE INSTRUCTIONS.
FOR RESIDENTIAL USE ONLY.
For questions about features, operation/performance parts, accessories or service, call:
1-626-453-0550
or visit our website at...
www.akdytrading.net
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 668 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for AKDY 668 Series

  • Page 1 Universal Installation Instructions and Use & Care Guide For questions about features, operation/performance parts, accessories or service, call: 1-626-453-0550 or visit our website at... www.akdytrading.net Model: 668 Series 63175 63190 IMPORTANT: READ AND SAVE THESE INSTRUCTIONS. FOR RESIDENTIAL USE ONLY.
  • Page 2: Table Of Contents

    TABLE OF CONTENTS RANGE HOOD SAFETY ..............2 INSTALLATION REQUIREMENTS ...........4 Tools and Parts Requirements ...........4 Location Requirements .............4 Installation Dimensions ............5 Venting Requirements ..............6 Electrical Requirements ............7 INSTALLATION INSTRUCTIONS ..........8 Prepare Location ..............8 Install Range Hood ..............10 Connect Vent System ..............11 Complete Installation ..............12 RANGE HOOD USE .................13 Range Hood Controls ..............14...
  • Page 3 IMPORTANT SAFETY INSTRUCTIONS WARNING: TO REDUCE THE RISK OF A RANGE TOP WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC GREASE FIRE: SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: Never leave surface units unattended at high settings. ■ Boil over cause smoking and greasy spillovers that may Use this unit only in the manner intended by the ■...
  • Page 4: Installation Requirements

    INSTALLATION REQUIREMENT TOOLS AND PARTS REQUIREMENTS Electrical drill or ratchet driver 1/2” drill bit for drilling pilot holes 1 ¼” drill bit for drilling electrical wiring access hole. Screwdrivers: Philips & Straight blade Pliers Tape measure or ruler and pencil Electrical supplies for wiring Aluminum foils tape and/or duct tape Hammer...
  • Page 5: Installation Dimensions

    INSTALLATION DIMENSIONS A. Countertop height B. Hood height from ceiling to bottom of the range hood filter surface: D-A-C=B C. Hood height: 24” (61.0 cm) min. from electric cooking surface, 27” (68.6 cm) min. from gas cooking surface, suggested 36” (91.4 cm) max. D.
  • Page 6: Venting Requirements

    VENTING REQIUREMENTS ■ Vent system must terminate to the Venting Method outdoors, except for non-vented (recirculating) installations. This canopy hood is factory set for through ■ Do not terminate the vent system in an the roof or wall. attic or other enclosed area. ■...
  • Page 7: Electrical Requirements

    Calculating Vent System Length ELECTRICAL REQIUREMENTS To calculate the length of the system you need, add the equivalent feet (meters) for each vent piece used in the system. Observe all governing codes and ordinances. Ensure that the electrical installation is adequate and in conformance with National Electrical Code, ANSI/NFPA 70 (latest edition), or CSA Standards C22.1-94,...
  • Page 8: Installation Instructions

    INSTALLATION INSTRUCTIONS PREPARE LOCATION It is recommended that the vent system be installed before hood is installed. ■ Before making cutouts, make sure there is proper clearance within the ceiling or wall for exhaust vent. ■ Check your ceiling height and the hood height maximum before you select your hood. ■...
  • Page 9 Vent Cover Bracket Installation 5. Mark the hole location. 6. Attach chimney mounting bracket to the wall by using two M5 x 12 screws. A. Central point B. M5 x 12 screw C. Chimney mounting bracket Complete Preparation Determine and make all necessary cuts in the wall for the vent system. Install the vent system before installing the hood.
  • Page 10: Install Range Hood

    INSTALL RANGE HOOD Using 2 or more people, hang range hood on two mounting screws through the mounting slots on back of hood. Excessive Weight Hazard Use two or more people to move and install range hood. Failure to do so can result in back or other injury. A.
  • Page 11: Connect Vent System

    CONNECT VENT SYSTEM For vented installation only: Install transition on top of hood (if removed for shipping) with M5 X 12 screws. A. Air outlet M5 X 12 screw C. Remove the tape from the flapper Install exhaust pipe. COMPLETE INSTALLATION(FOR NON- VENTED(RECIRCULATING) INSTALLATION ONLY Step 1: Do not install exhaust pipe, remove the grease filters, locate the blower inside the hood Step 2: Attach the carbon filters to both sides of the blower...
  • Page 12 INSTALL VENT COVERS When using both upper and lower vent covers, push lower cover down onto hood and lift upper cover to ceiling and install with two M5 x 12 screws NOTE: For vented installations, the upper vent cover maybe reversed to hide slots. A.
  • Page 13: Range Hood Use

    RANGE HOOD USE The range hood is designed to remove smoke, cooking vapors and odors from the cook top tea. For best results, start the hood before cooking and allow it to operate several minutes after the cooking is complete to clear all smoke and odors from the kitchen.
  • Page 14: Range Hood Controls

    RANGE HOOD CONTROLS Operating the lights The On/Off light button controls both lights. Press once for on and again for off. Operating the blower The blower speed buttons turn the blower on and control the blower speed and sound level for quiet operation.
  • Page 15: Range Hood Care

    RANGE HOOD CARE Cleaning IMPORTANT: Clean the hood and grease filters frequently according to the following instructions. Replace grease filters before operating hood. Exterior Surfaces To avoid damage to the exterior surface, do not use steel wool or soap-filled scouring pads. Always wipe dry to avoid water marks.
  • Page 16: Replacement

    Non-Vented (recirculating) Installation Filters: The carbon filter is not washable. It should last up to 6 months with normal use. For replacement please visit our website www.akdytrading.net Replacing the LED light Turn off the range hood and allow the LED to cool. To avoid damage or decreasing the life of the new bulb, do not touch bulb with bare fingers.
  • Page 17: Trouble Shooting

    TROUBLE SHOOTING Potential Effect of Potential Cause(s) Recommended Action(s) Failure Lamp does not turn Electronic Control a) Pressing any key the LCD lights up and does not work. Due to icons are in place? Over Voltage Yes, Proceed with the following diagnostic sequence No, Replace the control and user interface.
  • Page 18 in the white plastic. - Push inwards the motor/lamp connectors until the locking system on connectors is well attached. 5) Connect hood to power supply and verify. The blower is Filters are dirty 1) Verify that the grease and/or charcoal too noisy filters are clean.
  • Page 19: Warrenty & Services

    For three year from the date of purchase, when this major appliance is operated and maintained according to instructions attached to or furnished with the product, AKDY Home Improvement will pay for Factory Specified Parts. This limited warranty is valid only in the United States or Canada and applies only when the major appliance is used in the country in which it was purchased.