Sharp KB-3411JS Supplemental Service Manual page 32

Free standing range with microwave drawer
Hide thumbs Also See for KB-3411JS:
Table of Contents

Advertisement

KB-3411JS
KB-3411JK
KB-3411JW
BLOWER MOTOR REMOVAL
1. Disconnect the power supply cord.
2. Refer to the disassembly instructions as previously stated.
3. Unhook all wiring from Blower Motor (Fig. O-11)
4. Remove tape from Thermistor rear hole.
5. Remove the (2) screws holding the Blower Motor to the Rear Plate.
6. The Blower Motor is now free.
7. Proceed in reverse to reinstall the Blower Motor.
LOCK MOTOR REMOVAL
1. Disconnect the power supply cord.
2. Refer to the disassembly instructions as previously stated.
3. Unhook all wiring from Lock Motor (Fig. O-12).
4. Remove the (2) screws holding the Lock Motor to the Rear Plate.
5. Pull Lock Motor from Lock Motor Shaft.
6. The Lock Motor is now free.
7. Proceed in reverse to reinstall the Lock motor.
Fig. O-11
Fig. O-12
30

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kb-3411jkKb-3411jw

Table of Contents