Trim And Door Installation - Monessen Hearth HWB700OD Installation, Operation And Maintenance Manual

Residential and outdoor fireplace
Hide thumbs Also See for HWB700OD:
Table of Contents

Advertisement

T
D
RIM AND
OOR
INSTALLATION OF NON-COMBUSTIBLE FACING MATERIALS TO THE FRONT FACE OF THE FIREPL
INSTALLATION OF NON-COMBUSTIBLE FACING MATERIALS TO THE FRONT FACE OF THE FIREPLACE
COMBUSTIBLE FRAMING
MEMBERS FACING MATERIAL
TO TOP OF SPACERS.
F
26
IGURE
MANTEL INSTALLA
MANTEL INST
ALLATION
TION
COMB
COMBUSTIBLE FRAMING
MEMBERS
MEMBERS TO O
TOP OF SP
OP OF SPACERS
USE ONL
USE ONLY Y
NON-COMB
NON-COMBUSTIBLE
USTIBLE
MA
MATERIALS BELO
TERIALS BELOW W
TOP OF SP
OP OF SPACERS
F
27
IGURE
COMBUSTIBLE
SURROUND
PLACEMENT
COMBUSTIBLE SURROUND MATERIALS
COMBUSTIBLE SURROUND MATERIALS
MAY BE PLACED INSIDE THE SHADED
MAY BE PLACED INSIDE THE SHADED
AREAS. COMBUSTIBLES MAY NOT
AREAS. COMBUSTIBLES MAY NOT
OVERLAP EDGE OF BLACK PAINTED
OVERLAP EDGE OF BLACK PAINTED
FACE MORE THAN 1/8".
FACE MORE THAN 1/8".
G
D
I
LASS
OOR
NSTALLATION
This fireplace has been tested and listed for use with optional Model WSB54 glass doors. For installation of
the Model WSB54 glass doors, see the instructions provided with the doors.
I
NSTALLATION
12"
12"
MAX
MAX
USTIBLE FRAMING
CERS
CERS
OUTLINE OF
OUTLINE OF
FIREPLACE
FIREPLACE
FIREBRICK
FIREBRICK
NON-COMBUSTIBLE
FACING MATERIAL
FIREPLACE
FACE
STEEL LINTEL
(OPTIONAL)
CAUTION: DO NOT COVER
OR RESTRICT SIDE VENT
AREAS WITH SURROUND
OR TRIM MATERIALS.
F
26A
IGURE
COMB
COMBUSTIBLE MANTEL
USTIBLE MANTEL
TOP EDGE OF FIREPLA
OP EDGE OF FIREPLACE
18" MIN.
18" MIN. FR
FROM FIREPLA
OM FIREPLACE OPENING
TO BOTTOM OF COMBUSTIBLE MANTEL.
TO BOTTOM OF COMBUSTIBLE MANTEL.
(MANUF
(MANUFACTURER RECOMMEND
CTURER RECOMMENDATION)
TOP EDGE OF
OP EDGE OF
FIREPLACE OPENING
FIREPLA
CE OPENING
2 1/2"
2 1/2"
DO NOT RESTRICT
DO NOT RESTRICT
SIDE AIR INLETS
SIDE AIR INLETS
(REF.)
(REF.)
USE ONLY NON-COMBUSTIBLE
MATERIALS BELOW TOP OF SPACERS.
WARNING:
THE SPACE BETWEEN THE
FACE OF THE FIREPLACE
AND THE NON-COMBUSTIBLE
AND THE NON-COMBUSTIBLE
FACING MATERIAL MUST
MUST BE SEALED. FAILURE
MUST BE SEALED. FAILURE
TO PROPERLY SEAL THIS
CRACK CAN CAUSE A
POSSIBLE FIRE HAZARD AND
POSSIBLE FIRE HAZARD AND
WILL VOID THE WARRANTY.
CE
CE OPENING
TION)
EXTEND LINE FROM OPPOSITE
EXTEND LINE FROM OPPOSITE
REAR CORNER OF FIREBOX
REAR CORNER OF FIREBOX
PAST INSIDE OPENING OF THE
PAST INSIDE OPENING OF THE
FRONT FACE SIDE PANEL.
FRONT FACE SIDE PANEL.
53D9038. Rev 1 03/03
26

Advertisement

Table of Contents
loading

Table of Contents