Advertisement

Quick Links

p/n 76853 Rev. (-) ECN-12597
Model 8372EU Brewer
with optional
8900-Series
Glass Decanter
PRINTED IN UNITED STATES OF AMERICA
OWNERS MANUAL
for
BOTTLED WATER
DECANTER
COFFEE BREWERS
MODEL
8372EU
for
3 Gallon
and
5 Gallon
Plastic Bottles
Includes:
Installation
Operation
Use & Care
Servicing Instructions
M681EU 040913 cps
681EU

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Aquarius 8372EU and is the answer not in the manual?

Questions and answers

Summary of Contents for Bloomfield Aquarius 8372EU

  • Page 1 681EU OWNERS MANUAL BOTTLED WATER DECANTER COFFEE BREWERS MODEL 8372EU 3 Gallon 5 Gallon Plastic Bottles Includes: Installation Operation Use & Care Servicing Instructions Model 8372EU Brewer with optional 8900-Series Glass Decanter PRINTED IN UNITED STATES OF AMERICA p/n 76853 Rev. (-) ECN-12597 M681EU 040913 cps...
  • Page 2: Warranty Statement

    The prices charged by Bloomfield Industries for its products installation or eighteen (18) months from the date of shipment are based upon the limitations in this warranty.
  • Page 3: Table Of Contents

    TABLE OF CONTENTS Thank You for purchasing this Bloomfield Industries appliance. WARRANTY STATEMENT SPECIFICATIONS Proper installation, professional FEATURES & OPERATING CONTROLS operation and consistent PRECAUTIONS & GENERAL INFORMATION 3 maintenance of this appliance will AGENCY APPROVAL INFORMATION ensure that it gives you the very...
  • Page 4: Features & Operating Controls

    FEATURES AND OPERATING CONTROLS Fig. 1 Features & Operating Controls...
  • Page 5: Precautions & General Information

    PRECAUTIONS AND GENERAL INFORMATION WARNING: Electric Shock Hazard All servicing requiring access to non-insulated components must be performed by qualified service personnel. Do not open any access panels which require the use of tools. Failure to heed this warning can result in electrical shock. WARNING Electric Shock Hazard Brewer must be plugged into a properly grounded receptacle to prevent possible shock.
  • Page 6: Installation

    INSTALLATION INSTRUCTIONS READ THIS CAREFULLY BEFORE STARTING THE INSTALLATION IMPORTANT: Unpack the unit. Inspect all components for completeness and To enable the installer to make condition. Ensure that all packing materials have been removed a quality installation and to from the unit. minimize installation time, the Verify that the Spray Head Gasket (#33) and Spray Disk (#34) following suggestions and tests...
  • Page 7: Operation

    OPERATION START-UP CAUTION: Personal Injury For initial start-up, or if the brewer has not been used for an extended period of time: 5 Gallon water bottle can weigh ♦ Be sure spray disk and brew gasket are properly installed up to 50 pounds. Install bottle carefully.
  • Page 8 OPERATION (continued) WATER HEATER Water temperature is sensed by a thermobulb inserted into the water tank. This temperature signal is fed to the thermostat, which controls line power to the heating element. The setpoint temperature is adjustable at the thermostat. The element is protected from over- temperature by a hi-limit thermostat.
  • Page 9 BREWING COFFEE PREPARATION CAUTION: Burn Hazard Place one (1) genuine Bloomfield paper filter in the brew chamber. Add a pre-measured amount of fresh coffee grounds. Exposed surfaces of the Gently shake the brew chamber to level the bed of grounds. Slide...
  • Page 10: Cleaning Instructions

    CLEANING INSTRUCTIONS CAUTION: PROCEDURE: Clean Coffee Brewer Burn Hazard PRECAUTIONS: Disconnect brewer from electric power. Allow brewer to cool. Brewing and serving temperatures of coffee are FREQUENCY: Daily extremely hot. Hot coffee will cause TOOLS: Mild Detergent, Clean Soft Cloth or Sponge serious skin burns.
  • Page 11 CLEANING INSTRUCTIONS (continued) CAUTION: PROCEDURE: Clean and Sanitize Basin Pan Electric Shock Hazard PRECAUTIONS: Disconnect brewer from electric power. Allow brewer to cool. Removing the top panel will expose uninsulated circuits. FREQUENCY: Monthly Unplug the brewer before removing the top panel. TOOLS: #2 Phillips Head Screwdriver This procedure to be performed...
  • Page 12: Troubleshooting Suggestions

    Coffee level too high or low Timer out of adjustment Adjust timer Brew chamber overflows Too many filter papers or wrong Use one (1) genuine Bloomfield filter paper filter per brew Brew chamber dispense hole Thoroughly clean brew chamber plugged...
  • Page 13: Servicing Instructions

    SERVICING INSTRUCTIONS ACCESS PANELS CAUTION Electric Shock Top panel is held by four screws at the corners. Hazard Front panel is held by two clips under each warmer plate, three Opening access panels or screws at the bottom and a retaining lip at the top. removing warmer plates on this Top rear panel is held by two clips under the warmer plate.
  • Page 14 SERVICING INSTRUCTIONS (continued) IMPORTANT: Adjust timer with TIMER ADJUSTMENT a full water bottle installed in the The amount of water dispensed automatically during a brew cycle bottle ring. is controlled by the timer. Place empty decanter under brew chamber. Press BREW button.
  • Page 15 SERVICING INSTRUCTIONS (continued) IMPORTANT: When replacing REPLACE HEATING ELEMENT heating element, also replace Remove tank lid assembly per above. seal gaskets. Remove two hex nuts holding element to cover. Pull element from mounting holes. Reassemble in reverse order. REPLACE WARMER ELEMENT Remove warmer plate by turning counter-clockwise.
  • Page 16: Delime Water Tank

    SERVICING INSTRUCTIONS (continued) CAUTION - PROCEDURE: Delime the Water Tank CHEMICAL BURN HAZARD PRECAUTIONS: Disconnect brewer from electric power. Allow brewer to cool. Deliming chemicals are caustic. Wear appropriate protective FREQUENCY: As required (Brewer slow to heat) gloves and goggles during this procedure.
  • Page 17 Should deliming hoses become necessary, 8. Reinstall wiring to heating element and thermostat. Reinstall Bloomfield recommends the hi-limit thermostat . Verify that all internal components replacing the hoses. are dry, then reinstall the top panel.
  • Page 18: Exploded Views & Parts Lists

    EXPLODED VIEW & PARTS LIST 8372 PLUMBING COMPONENTS ITEM PART# DESCRIPTION 83538 TUBE, FAUCET SUPPLY 10” SILICONE 8043-5 STRAP, TANK LID HOLD DOWN 8043-13 ELBOW, BREW NOZZLE SILICONE 8783-1 FAUCET 82681 WASHER, FLAT SS 15/32 x 1-1/8 OD 8543-42 GASKET, SPRAY DISK 84132 SPRAY DISK 8543-45...
  • Page 19 EXPLODED VIEW & PARTS LIST (continued) ITEM PART# DESCRIPTION 8533-32 WARMER, 240V 100W 85647 SWITCH, WARMER ON/OFF 250V 85646 SWITCH, BREW MOMENTARY 250V 8738-2 INDICATOR LIGHT, GREEN 240V 82748 TIMER, 8 MIN 8889-1 POWER CORD, EURO 35-212 STRAIN RELIEF 84619 SOLENOID, BREW 220/240V 86280 THERMOSTAT, 199ºF...
  • Page 20 EXPLODED VIEW & PARTS LIST (continued) ITEM PART# DESCRIPTION 8700-16 PLATE, WARMER COVER 8543-42 GASKET, SPRAY DISK 84132 SPRAY DISK 8543-45 BREW HEAD (must be drilled & riveted to install 8706-75 BUTTON PLUG, 2” DIA 81732 LEG ADJUSTABLE 8033-55 LEG, METAL 8033-56 FOOT, RUBBER 8543-69...
  • Page 21: Wiring Diagram

    WIRING DIAGRAM...
  • Page 22 Bloomfield Industries proudly supports CFESA Commercial Food Equipment Service Association Bloomfield Industries, Inc. Division of Carrier Commercial Refrigeration In US and Canada Telephone: 775-689-5700 Fax: 888-492-2783 Fax: 800-356-5142 ( for orders only website: www.wellsbloomfield.com PRINTED IN UNITED STATES OF AMERICA...