ELECTRICAL INSTALLATION INSTRUCTIONS (continued)

TOTAL MASSAGE WHIRLPOOLS

The whirlpool pump and blower should be installed on a 120 vac, 20 amp dedicated circuit. The circuit should be
hard-wired from the electrical power supply panel. The circuit must be a three (3) wire circuit from the electrical supply
panel. A grounded neutral wire and a third wire, earth ground, are essential. A SEPARATE 15 AMP MAXIMUM GFCI
CIRCUIT IS REQUIRED IF THE OPTIONAL HEATER IS INSTALLED (SEE INSTALLATION INSTRUCTIONS
SUPPLIED WITH THE HEATER MODEL NUMBER – 494-1000).
TOTAL MASSAGE CIRCUIT WITH OPTIONAL HEATER
CO NT R OL P A D
P UM P
H E AT E R
754764-100 Rev. A
P U M P
T I M E R
C ONT RO L
120 V, 60 Hz
15 AMP GFCI
P U M P
FLO W
C O N TR O L
V A LVE
ELECTRICAL
FEED
GFCI
GFCI
12
V A R I A B LE
C O N TR O L
B LO W ER
120 V, 60 Hz
20 AMP GFCI