Tyco Electronics AMP 1490530–1 Instruction Sheet

Advertisement

Quick Links

Green Pair Lights
Shield Light
Tone Light
Tone Button
Figure 1

1. INTRODUCTION

These instructions deal with the Four–Pair UTP
Tester 1490530–1 shown in Figure 1.
The Four–Pair UTP Cable Tester 1490530–1 is a
unique blend of a popular type of low–end tester
interface with an advanced microprocessor controller.
The most popular aspects of this type of tester are an
indication at both ends that the cable has been
tested, no buttons to push to perform a test and a
case that snaps together for storage. The
microprocessor brings the additional features of
automatic power management, split pair error
detection, direct indication of the type and location of
faults and tone generation.

2. DESCRIPTION

The main unit has four green pair lights, a green
shield light, four red fault lights, a red battery low light
and a green tone light. The remote unit has four
amber pair lights. When a connection from the main
unit to the remote is sensed, testing begins
automatically. On the main unit, the lights for each
pair will either be ON, OFF or FLASHING. An ON
light indicates a good pair, an OFF light indicates an
E
2002 Tyco Electronics Corporation, Harrisburg, PA.
All International Rights Reserved.
AMP and Tyco are trademarks.
*Trademark
Four–Pair UTP Cable Tester 1490530–1
open pair and a FLASHING light indicates a bad pair.
Amber
If a pair is bad, one or more of the fault lights will be
Pair Lights
flashing to indicate the type or types of faults. On the
remote unit, the pair lights are either ON or OFF. An
ON light indicates a good pair, and an OFF light
indicates an open or bad pair. Holding down the tone
button until all lights momentarily turn on starts the
Debug Mode. The pairs are stepped through one at a
time to display connection and fault information on a
pair–by–pair basis. A second press of the tone button
turns off debug or completion of two complete cycles.
When not in debug mode, pressing and releasing the
tone button in less than 1.5 seconds causes the
Four–Pair UTP Tester to generate a warble tone
Detachable
signal on all pairs, flashing the tone light to indicate
Remote
tone is on. The tone will turn off automatically after
three hours, or with a second press of the tone
Fault Lights
button.
Battery Low

3. SPECIFICATIONS

NOTE
Battery Cap
Electrical
Battery Life, typical Alkaline – Times are for the full capacity of the
battery used continuously in one of the following modes:
Cable Types:
Minimum Cable Length for Testing for Split Pairs:
Maximum Cable Length for Testing:
Coax Cable:
Environmental
Temperature – Operating: 0
Humidity – 10% to 90%, non–condensing
Physical
Length: 14.5 cm [5.70 in]
Width: 7.2 cm [2.85 in]
Height: 3.0 cm [1.20 in]
Weight (with battery): 162 gm [(5.7 oz]
This controlled document is subject to change.
For latest revision call the AMP FAX* number.
Specifications subject to change.
Standby: 2.5 years
Cable Testing: 20 hours
Tone Mode: 170 hours
Shielded or Unshielded, Cat 5e, Cat 5, Cat 4, or Cat 3
1 meter (3 feet)Return Loss: 14db @ 600 ohms
305 meters (1000 feet)
100 ohms maximum DC resistance, center conductor
plus shield
_
_
to 50
C; Storage: –20
TOOLING ASSISTANCE CENTER 1–800–722–1111
AMP FAX/PRODUCT INFO 1–800–522–6752
For Regional Customer Service, visit our website at
www.tycoelectronics.com
Instruction Sheet
408–8653
14 MAY 02 Rev O
_
_
to 70
C
1 of 4
LOC B

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AMP 1490530–1 and is the answer not in the manual?

Questions and answers

Summary of Contents for Tyco Electronics AMP 1490530–1

  • Page 1 Weight (with battery): 162 gm [(5.7 oz] pair will either be ON, OFF or FLASHING. An ON light indicates a good pair, an OFF light indicates an 2002 Tyco Electronics Corporation, Harrisburg, PA. This controlled document is subject to change. TOOLING ASSISTANCE CENTER 1–800–722–1111 1 of 4 For latest revision call the AMP FAX* number.
  • Page 2 408–8653 Four–Pair UTP Cable Tester 1490530–1 4. FEATURES 5.2. Testing an Installed Cable (Office Jack to Patch Panel) The Four–Pair UTP Cable Tester 1490530–1 contains 1. Remove the remote unit from main unit by the following features: sliding remote towards top of the main unit. S Auto–on and auto–off when testing cables, by 2.
  • Page 3 408–8653 Four–Pair UTP Cable Tester 1490530–1 type of error to mask lower severity errors. For example, if there is a short in the cable, miswires, reversals and split pairs cannot be detected for the pairs involved in the short fault. Multiple faults on multiple pairs can be better understood by using the debug mode to examine the errors one pair at a time.
  • Page 4 For Four–Pair UTP Cable Tester repair service, especially when there are multiple errors on multiple please contact a Tyco Electronics representative at pairs. To enter the debug mode, press and hold the 1–800–526–5136.

Table of Contents