BERJAYA BJY-G30-1BD Operation Manual

BERJAYA BJY-G30-1BD Operation Manual

Gas heated baking oven

Advertisement

Gas Heated Baking Oven
(Ketuhar Gas)
BJY-G30-1BD
BJY-G60-1BD
BJY-G120-2BD
BJY-G180-3BD
BJY-G270-3BD
50 Hz / 60 Hz
Common Usage
Thank you for purchasing BERJAYA product. Please read this
operation manual carefully before operating the product.
Please keep this manual in a safe place for future reference.
(Terima kasih kerana membeli produk BERJAYA. Sila baca
panduan operasi dengan teliti sebelum menggunakan produk
ini. Simpankan panduan operasi ini dengan selamat untuk
rujukan masa depan.)
(OM - Gas Heated Baking Oven - BD - REV 01 / 2014 / 12)
Operation Manual
(Panduan Operasi)
Post the followings instructions in a prominent location
in the event you smell gas : -
(Pasangkan arahan yang berikut pada tempat yang
mudah dibaca, sekiranya terhidu bau gas :-)
( a ) Off gas supply.
(Tutupkan bekalan gas.)
( b ) Open all windows.
(Buka semua tingkap.)
( c ) Do not On/Off any electrical switches.
(Jangan hidup atau matikan sebarang suis elektrik.)
( d ) Call for professional service.
(Dapatkan perkhidmatan yang bertauliah.)
WARNING : Improper installation, adjustment, alteration,
service or maintenance can cause property damage,
injury or death. Read the installation, operating and
maintenance instructions thoroughly before installing or
servicing this equipment
(AMARAN : Segala pemasangan, pelarasan, perubahan,
perkhidmatan atau penyelenggaraan yang tidak betul akan
menyebabkan kerosakkan kepada harta benda, kecederaan
atau mati. Bacakan arahan pemasangan, operasi dan
penyelenggaraan dengan teliti sebelum kerja pemasangan
atau penyelenggaraan dimulakan.)
FOR YOUR SAFTY
(DEMI KESELAMATAN ANDA)
Do not store or use gasoline or other flammable vapors
or liquids in the vicinity of this or any other appliance.
(Jangan simpan atau gunakan petrol atau sebarang
cecair yang mudah bakar di sekitar alat ini.)
Contents (Kandungan) : -
- Installation (Pemasangan) ............................
LPG Dan NG) ..............................................
- Leak Testing (Ujian Kebocoran) .....................
- Circuit Diagram (Rajah Litar) ..........................
- Operation (Operasi) .....................................
- Warning (Amaran) ........................................
- Cleaning (Pembersihan) ...............................
- Memo (Memo) .............................................
2
2
3
4
4
5-6
5-6
7
7
7-8
9
9
9
10

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BJY-G30-1BD and is the answer not in the manual?

Questions and answers

Summary of Contents for BERJAYA BJY-G30-1BD

  • Page 1: Table Of Contents

    Common Usage - Explosive Drawing (Rajah Terperinci) ………….. - Component List (Senarai Komponen) …………. Thank you for purchasing BERJAYA product. Please read this - Technical Specifications (Spesifikasi Teknikal).. operation manual carefully before operating the product. - Circuit Diagram (Rajah Litar) ……………………..
  • Page 2: Installation (Pemasangan)

    INSTALLATION (PEMASANGAN) - Installation and maintenance of this equipment must be performed by qualified personnel. (Pemasangan dan penyelenggaraan alat ini hendaklah dilakukan oleh wakil yang bertauliah.) - This oven uses low pressure Liquefied Petroleum Gas (2800 Pa) or low pressure Natural Gas. (2000Pa). (Bahan api alat ini merupakan Gas Petroleum Cecair bertekanan rendah (2800Pa) atau Gas Asli bertekanan rendah (2000Pa.) - The use of this equipment must conform regulations set by local authorities.
  • Page 3: Gas Connector (Penyambung Gas)

    - Use the correct type of gas regulator as show in the table : - (Jenis regulator (injap kawalan kadar aliran gas) hendaklah bersesuaian dengan model seperti dalam jadual yang berikut : - ) Model (Model) Flow Rate (m3 /hr) (Kadar Aliran) (m3 /jam) BJY-G30-1BD BJY-G60-1BD BJY-G120-2BD BJY-G180-3BD...
  • Page 4: Interchanging Between Lpg And Ng (Perbezaan Lpg Dan Ng)

    - Size of gas nozzle depends on the model and the type of gas used. Refer to the following table for the correct nozzle size : - (Saiz mucung penunu gas hendaklah bersesuaian dengan model seperti dalam jadual yang berikut : - ) Model Nozzle BJY-G30-1BD Ø 1.0mm Ø 1.6mm BJY-G60-1BD Ø...
  • Page 5: Explosive Drawing (Rajah Terperinci)

    EXPLOSIVE DRAWING (RAJAH TERPERINCI) - BJY-G30-1BD 130mm 130mm G30-1BD Ø1.0 Ø1.6 COMPONENTS LIST (SENARAI KOMPONEN) - BJY-G30-1BD Description (Butir-Butir) Code (Kod) 2 Head Electromagnetic Valve (Injap Elektromagnetik) IC-G30N-2EMV Blower (Kipas Peniup) IC-G30N-BW Burner - 785mm (Penunu - 785mm) IC-G30N-BR Ignition Head (Pengeluar Bunga Api) - Length = 130mm, Probe = L Shape...
  • Page 6 EXPLOSIVE DRAWING (RAJAH TERPERINCI) - BJY-G60-1BD, BJY-G120-2BD, BJY-G180-3BD, BJY-G270-3BD G60-1BD 1080mm G120-2BD G60-1BD = 350mm G180-3BD G120-2BD = 830mm G270-3BD 1510mm G180-3BD = 1310mm G270-3BD = 1310mm (L mm) G60-1BD Ø1.2 Ø2.1 G120-2BD Ø1.2 Ø2.1 G180-3BD Ø1.2 Ø2.1 G270-3BD Ø1.3 Ø2.2 COMPONENTS LIST (SENARAI KOMPONEN) - BJY-G60-1BD, BJY-G120-2BD, BJY-G180-3D, BJY-G270-3BD Description (Butir-Butir)
  • Page 7: Technical Specifications (Spesifikasi Teknikal)

    210W 20 - 400˚C 90Kg/h 2000Pa CIRCUIT DIAGRAM (RAJAH LITAR) BJY-G30-1BD, BJY-G60-1BD, BJY-G120-2BD, BJY-G180-3BD, BJY-G270-3BD K1 = Power Switch (Suis Kuasa) K2 = Lamp Switch (Suis Lampu) K3 = Operation Switch (Suis Operasi) HL = Operation Power (Kuasa Operasi) DL = Lamp (Lampu)
  • Page 8 BJY-G30-1BD BJY-G60-1BD, BJY-G120-2BD, BJY-G180-3BD, BJY-G270-3BD Knob - Air Vent Control Top Temperature (Pemutar - Control Light Pintu Angin (Lampu Kontrol Thermostat Kawalan) Suhu Atas) (Termostat) Knob - Air Top Temperature Vent Control Control Light (Pemutar - (Lampu Kontrol Pintu Angin...
  • Page 9: Warning (Amaran)

    WARNING (AMARAN) - Do not use high pressure LPG or NG. (Jangan menggunakan LPG atau NG yang bertekanan tinggi.) - Keep a safe distance of your body and eyes from the oven when the door is opened. (Semasa pintu ketuhar dibuka, jauhkan badan dan mata anda dari ketuhar.) - Install an exhaust fan on top of the oven.
  • Page 10: Memo (Memo)

    Flame extinguishes suddenly and - Backflow needle not properly - Adjust the position of the needle so alarm is activated positioned. that it is in contact with the flame. (Api tiba-tiba padam dan isyarat (Kedudukan jarum aliran balik tidak (Alihkan kedudukan jarum itu supaya amaran berbunyi) betul.) ia bersentuhan dengan nyalaan api.)

This manual is also suitable for:

Bjy-g60-1bdBjy-g120-2bdBjy-g180-3bdBjy-g270-3bd

Table of Contents