Safety Precautions; General Guidelines; Touch-Current Check - Panasonic TH-L42S10M Service Manual

Table of Contents

Advertisement

1 Safety Precautions

1.1.

General Guidelines

1. When servicing, observe the original lead dress. If a short circuit is found, replace all parts which have been overheated or
damaged by the short circuit.
2. After servicing, see to it that all the protective devices such as insulation barriers, insulation papers shields are properly
installed.
3. After servicing, make the following leakage current checks to prevent the customer from being exposed to shock hazards.
1.2.

Touch-Current Check

1. Plug the AC cord directly into the AC outlet. Do not use an isolation transformer for this check.
2. Connect a measuring network for touch currents between each exposed metallic part on the set and a good earth ground
such as a water pipe as shown in Figure 1.
3. Use the Leakage Current Tester (Simpson 228 or equivalent) to measure the potential across the measuring network.
4. Check each exposed metallic part and measure the voltage at each point.
5. The potential at any point (touch current) expressed as voltage U
For AC: U
= 35 V (peak) and U
1
For DC: U
= 1.0 V,
1
NOTE :
The limit value of U
2
DC.
The limit value U
= 35 V (peak) for AC correspond to the value 70 mA (peak) AC for frequencies greater than 100 kHz.
1
6. Should a measurement be out of the limits specified, there is a possibility of a shock hazard, and the equipment should be
repaired and rechecked before it is returned to the customer.
= 0.35 V (peak);
2
= 0.35 V (peak) for AC and U
and U
, do not exceed the following values:
1
2
= 1.0 V for DC correspond to the values 0.7 mA (peak) AC and 2.0 mA
1
5
TH-L42S10M

Advertisement

Table of Contents
loading

Table of Contents