OPERATION NOTES
Make sure that the conductive side of a flexible board does not have any stain or foreign materials.
Do not touch the conductive side of flexible boards with bare hands.
Plug in a flexible board straight, fully into the connector until it reaches the end inside. (Fig. 1, Fig. 2, Fig. 3)
OK
(The flexible board was plugged in straight
and completely)
Flexible
Board
Reference
line
Connector
Connector
Fig. 1
When opening the connector's holder in direction A, do not open
it with excessive force.
Holder
Connector
A
• Make sure that the flat cable and flexible board are not cracked
or bent at the contact end.
• Do not apply excessive force to the gilded flexible board.
• The proper way to disconnect a connector is to grab the con-
nector instead of the wires. If you pull on the wires, they might
be broken.
• The proper way to connect a connector is to grab the connector
instead of the wires. If you push on the wires, they might be
broken.
SERVICE TOOLS
Display
Use
B-40
Adhesive bond (B-40)
G-85
Grease (G-85)
2. DISASSEMBLY & ASSEMBLY
(The flexible board was plugged in
crooked.)
Flexible
Flexible
Board
Board
Reference
line
Connector
A
Flexible Board
Part No.
J-6082-614-A
J-6082-626-A
NG
Reference
Flexible
Board
Connector
Fig. 2
When closing the connector's holder, press it evenly while pushing
a flexible board in direction B.
Connector
Insulation side
Cut and remove the part of gilt
which comes off at the point.
(Be careful or some
pieces of gilt may be left inside)
2-1
ILCE-7M3/7M3K
NG
(The flexible board was not plugged in
completely.)
Flexible
Board
line
Connector
Connector
Fig. 3
Holder
Flexible Board
B
Flexible
Board
SYS SET

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ilce-7m3k

Table of Contents