Advertisement

Quick Links

User Manual
BNC
Coaxial Calibration Kit
DC to 10 GHz
Models: FMCK1024
Fairview Microwave
301 Leora Ln., Suite 100. Lewisville, TX 75056
Tel: 1-800-715-4396 or (972) 649-6678
Fax: (972) 649-6689
sales@fairviewmicrowave.com
|
tech_support@fairviewmicrowave.com
© 2020 Infinite Electronics, Inc., Fairview Microwave is a registered trademark of Infinite Electronics, Inc.

Advertisement

Table of Contents
loading

Summary of Contents for Infinite Fairview Microwave FMCK1024

  • Page 1 DC to 10 GHz Models: FMCK1024 Fairview Microwave 301 Leora Ln., Suite 100. Lewisville, TX 75056 Tel: 1-800-715-4396 or (972) 649-6678 Fax: (972) 649-6689 sales@fairviewmicrowave.com tech_support@fairviewmicrowave.com © 2020 Infinite Electronics, Inc., Fairview Microwave is a registered trademark of Infinite Electronics, Inc.
  • Page 2: Warranty

    User Manual | BNC Coaxial Calibration Kits Warranty Fairview Microwave hardware products are warrantied against defects in materials and workmanship for a period of one year from the date of shipment. During the warranty period, Fairview Microwave will, at its option, either repair or replace products which prove to be defective.
  • Page 3: Table Of Contents

    Calibration Kit Contents ............................. 7 Standard Definitions ..............................8 Resources .................................. 10 Datasheets ................................10 Website .................................. 10 Contacts ..................................11 Customer Support & Sales ..........................11 © 2020 Infinite Electronics, Inc., Fairview Microwave is a registered trademark of Infinite Electronics, Inc.
  • Page 4: General Information

    User Manual | BNC Coaxial Calibration Kits General Information Calibration Kit Description These Fairview Microwave BNC coaxial calibration kits are designed to provide accurate calibrations of network analyzers in the DC to 10 GHz range. These kits include all the necessary calibration standards and associated hardware needed for the accurate calibration of most network analyzers.
  • Page 5: Connector Description

    Should a connector become damaged, it should be repaired before it is used again or replaced immediately. A damaged connector can damage other mated connectors. © 2020 Infinite Electronics, Inc., Fairview Microwave is a registered trademark of Infinite Electronics, Inc.
  • Page 6: Connector Tightening

    User Manual | BNC Coaxial Calibration Kits Connector Tightening Damage to a calibration standard or attaching connector can occur if the device is turned instead of the connector’s coupling nut. ALWAYS turn the coupling nut when making connections. Never turn or spin the connectors.
  • Page 7: Calibration Kit Contents

    1 ea Short, male FMSC3020 1 ea Open, female FMSC3034 1 ea Open, male FMSC3035 1 ea Load, female FMTR1064 1 ea Load, male FMTR1065 © 2020 Infinite Electronics, Inc., Fairview Microwave is a registered trademark of Infinite Electronics, Inc.
  • Page 8: Standard Definitions

    User Manual | BNC Coaxial Calibration Kits Standard Definitions Vector Network Analyzer hardware and test cables have a set of well understood systematic errors that affect the unprocessed measurements made by the instrument. The calibration standards in this kit have precisely-known electrical behavior, and during calibration the VNA software uses the raw measurement data and the known behavior of the standards to calculate the phase and magnitude of up to 12 complex error terms at each frequency point of the calibration.
  • Page 9 © 2020 Infinite Electronics, Inc., Fairview Microwave is a registered trademark of Infinite Electronics, Inc.
  • Page 10: Resources

    User Manual | BNC Coaxial Calibration Kits Resources Datasheets: BNC Calibration Kits: https://www.fairviewmicrowave.com/images/ProductPDF/FMCK1024.pdf Website: Fairview Microwave Calibration Kits: https://www.fairviewmicrowave.com/nsearch.aspx?Category=Calibration+Kits+Portable^Calibration+Kits^ Calibration+Kits+Components&keywords=calibration+ports+vna&sort=y&searchtype=1&view_type=grid Fairview Microwave Test and Measurement Products: https://www.fairviewmicrowave.com/nsearch.aspx?Category=Calibration+Kits+Portable^Calibration+Kits^ Calibration+Kits+Components^Adapters^Data+Cable+assemblies^Cable+assemblies^Connectors^VNA+ Test+Cables&keywords=Banana+Alligator+Spade+Breakout+calibration+ports+vna+armored+test&searc htype=1&no_metaphones=0:1&sort=y&view_type=grid fairviewmicrowave.com...
  • Page 11: Contacts

    301 Leora Ln., Suite 100 Lewisville, TX 75056 Phone: (800) 715-4396 (972) 649-6678 Fax: (972) 649-6689 Sales Email: sales@fairviewmicrowave.com Customer Support Email: tech_support@fairviewmicrowave.com Website: https://www.fairviewmicrowave.com © 2020 Infinite Electronics, Inc., Fairview Microwave is a registered trademark of Infinite Electronics, Inc.

Table of Contents