Page 1
Hot Water Boilers Operating instructions and maintenance enclosed Thoroughly read and understand instructions Always leave this manual with stove owner Follow the instructions within this manual. If instructions are not followed, a fire may result causing property damage, personal injury, or even death.
Page 2
KEYSTOKER stoker boiler unit. Selection of location. Keystoker boilers are available with fire door on the right or left side. When you stand at the stoker end of the boiler and look directly over top of boiler toward stack end, you may choose to have a fire door on the right or left side of boiler.
Page 3
KEYSTOKER BOILER INSTALLATION INSTRUCTIONS Install a domestic water mixing valve, we recommend a Honeywell AM-1 series not included with boiler install as per manufactures instructions (See Diagram Pg 5). If an automatic fill valve is desired, install as per manufacture’s instructions.
Page 4
KEYSTOKER BOILER INSTALLATION INSTRUCTIONS Install 4006B hi limit into well in by-pass loop. (See Diagram Pg 6 ). Your stoker must be on its own circuit. From main breaker to boiler use 12-2 wire with ground on a 20 amp breaker. Follow wiring diagram and any applicable UL and local code Stack pipe and draft control installation: Stack pipe may now be connected from boiler to chimney, using as few elbows as possible.
Page 5
KEYSTOKER BOILER INSTALLATION INSTRUCTIONS As prices of fuel continues to increase –KEYSTOKER – continues to improve and make its product more fuel efficient. To obtain a more complete burn out of coal, a small secondary blower motor was attached to the stoker unit.
KEYSTOKER BOILER INSTALLATION INSTRUCTIONS Front View...
Page 9
KEYSTOKER BOILER INSTALLATION INSTRUCTIONS 1. Stoker Body 14. Pusher Bar Drive Shaft 2. Side Rail Left K-2C 15. Bearing K-17 3. Side Rail Right K-1C 16. Feed Crank K-7 4. Grate K-15-1-L 17. Feed Assembly Connector K-6 5. Grate K-15-2-L 18.
Page 10
KEYSTOKER BOILER INSTALLATION INSTRUCTIONS Oil the stoker motor and circulator annually with a good grade of light lubricating oil. DO NOT OVER OIL. Gear box uses #90 gear oil and should be filled from ½ to ¾ full. Oil level can be measured with wire or straw dipped through top lid of gear box while stoker unit is not running.
Page 11
KEYSTOKER BOILER INSTALLATION INSTRUCTIONS HIGH LIMIT AQUASTAT – This control should be mounted in bypass loop above boiler. This acts only as a safety control and should be set at least 220 degrees. If boiler temperature becomes too high, this control starts circulator pump to relieve boiler temperature and will heat radiators, acting as a signal.
Page 13
KEYSTOKER BOILER INSTALLATION INSTRUCTIONS TROUBLE SHOOTING HINTS PROBLEM POSSIBLE CAUSE REMEDY Stoker doesn’t run Main circuit breaker tripped Reset Main fuse blown Replace Fuse on stoker blown Replace Motor out on reset Press rest button on motor Lo water level (steam)
KEYSTOKER BOILER INSTALLATION INSTRUCTIONS TROUBLE SHOOTING HINTS PROBLEM POSSIBLE CAUSE REMEDY Stoker runs but Feed nut backed off Increase feed-see preceding doesn’t feed coal too far. instructions. Obstruction in throat Empty hopper and remove of stoker. obstruction. Empty hopper –free- use dry...
Page 15
KEYSTOKER BOILER INSTALLATION INSTRUCTIONS SAFETY THE BURNING OF ALL FOSSIL FUELS GENERATES CARBON MONODIDE GASES. CARBON MONODIDE GASES ARE TOXIC. CAN CAUSE SICKNESS, AND CAN BE FATAL. TO PREVENT toxic carbon monoxide gases from entering the home, certain precautions must be taken.
Page 16
KEYSTOKER BOILER INSTALLATION INSTRUCTIONS Hot Water Checklist Thermostat Relief Pressure/Temperature Gauge 40006B with Well Fire Door Draft Regulator Control Instructions Warranty Card Low Water Cutoff Well 2 - 5/16 Stoker Bolts 2 - 3/8 Nuts 6 3/8 Washers 4 Hopper Washers...