7
WIRING DIAGRAM
PCA-A24KA4.TH
SYMBOL
NAME
I.B
INDOOR CONTROLLER BOARD
CN2L
CONNECTOR (LOSSNAY)
CN24
CONNECTOR (BACK-UP HEATING)
CN30
CONNECTOR (LLC)
CN32
CONNECTOR (REMOTE SWITCH)
CN41
CONNECTOR (HA TERMINAL-A)
CN51
CONNECTOR (CENTRALLY CONTROL)
CN105
CONNECTOR (RADIO FREQUENCY INTERFACE)
FUSE
FUSE (T6.3AL250V)
LED1
POWER SUPPLY (I.B)
LED2
POWER SUPPLY (R.B)
LED3
TRANSMISSION (INDOOR-OUTDOOR)
SW1
SWITCH (MODEL SELECTION)
SW2
SWITCH (CAPACITY CODE)
SWE
CONNECTOR (EMERGENCY OPERATION)
X1
RELAY (DRAIN PUMP)
MF
FAN MOTOR
MV
VANE MOTOR
RFI
RADIO FREQUENCY INTERFACE FOR RF THERMOSTAT
The black square(■)indicates a switch position.
<Table 1>
<Table 2>
SW1(MODEL SELECTION)
SW2(CAPACITY CODE)
SW1
MODELS
Manufacture/Service

PCA-A24KA4

1 2 3 4 5
ON
OFF

PCA-A30KA4

I.B
20
18
16
14
12
10
8
6
4
19
17
15
13
11
9
7
5
3
VANE
CNV
(WHT)
I-SEE
SENSOR
WIRELESS
CN4Y
CN90
(WHT)
(WHT)
1
9
1
4
5
4
9
5
CNB
BZ
I-SEE
SENSOR
M
SW1
LED2
I-SEE SENSOR
(OPTION PART)
MV
SW2
LED1
RU
W.B
(OPTION PART)
Notes:
1.Symbols used in wiring diagram above are,
2.Indoor and outdoor connecting wires are made with polarities, make wiring matching terminal numbers (S1, S2, S3).
3.Since the outdoor side electric wiring may change, be sure to check the outdoor unit electric wiring for servicing.
1:Use copper supply wire.
OCH501
PCA-A30KA4.TH
SYMBOL
TB4
TERMINAL BLOCK (INDOOR/OUTDOOR CONNECTING LINE)
TERMINAL BLOCK (REMOTE CONTROLLER
TB5
TRANSMISSION LINE)
TH1
ROOM TEMP. THERMISTOR
(32ºF / 15kΩ, 77ºF / 5.4kΩ DETECT)
TH2
PIPE TEMP. THERMISTOR/LIQUID
(32ºF / 15kΩ, 77ºF / 5.4kΩ DETECT)
TH5
COND. / EVA. TEMP. THERMISTOR
(32ºF / 15kΩ, 77ºF / 5.4kΩ DETECT)
OPTION PARTS
PCB FOR IR WIRELESS REMOTE CONTROLLER
W.B
BZ
BUZZER
LED1
LED (OPERATION INDICATION : GREEN)
See table 1
LED2
LED (PREPARATION FOR HEATING : ORANGE)
See table 2
RECEIVING UNIT
RU
SW1
EMERGENCY OPERATION (HEAT)
SW2
EMERGENCY OPERATION (COOL)
DP
DRAIN PUMP
FS
DRAIN FLOAT SWITCH
R.B
WIRED REMOTE CONTROLLER BOARD
TB6
TERMINAL BLOCK (REMOTE CONTROLLER
TRANSMISSION LINE)
MT
I-SEE SENSOR MOTOR
SW2
Manufacture/Service
MODELS
Manufacture/Service
1 2 3 4 5
1 2 3 4 5
PCA-A36KA4
ON
OFF
1 2 3 4 5
1 2 3 4 5
PCA-A42KA5
ON
OFF
Refer to tables 1 and 2
J41
J42
2
SW1
SW2
1
CN51(WHT)
Pair No.
5
CN2L
(RED)
2 1
LED3
LED2
LED1
ON OFF
I-SEE
SENSOR MOTOR
FLOAT SW
CN6Y
CN105
CN4F
(RED)
(RED)
(WHT)
1
6
1
5
1
4
5
When attaching
When attaching
M
drain pump
drain pump
RFI
(Option part),
(Option part)
MT
remove the
FLOAT SW
jumper
CN4F
connector
(WHT)
CN4F and fit
the drain float
switch (FS).
PCA-A36KA4.TH
NAME
(OPTION PART)
TB5
1
ON
2
OFF
TRANSMISSION
WIRES
ON
DC12V
OFF
2
CN32
(WHT)
1
3
3
1
CN24
INDOOR/OUTDOOR
(YLW)
COMMUNICATION
CN3C
1
2
1
(BLU)
CN41(WHT)
1
2
REMOCON
4
1
CN22
SWE
(BLU)
LIQUID/PIPE
INTAKE
CN30
CN44
CN20
(WHT)
(RED)
(GRN)
1
3
1
4
1
2
TH2 TH5
TH1
Be sure to turn off the source power
1
4
and then disconnect fan motor connector CNMF.
(Failure to do so will cause trouble in fan motor)
FS
:Connector,
:Terminal block.
12
PCA-A42KA5.TH
R.B
TB4
TB6
YLW
YLW
1
S1
ORN
ORN
2
S2
S3
ORN
BRN
1 3 5
OUTDOOR
CN01
(BLK)
DC294~325V
RECTIFICATION
FUSE
X1
FAN
CNMF
(WHT
)
DP
3
1
7
4
1
CNP
(BLU)
M
MS
3~
1~
DP (OPTION PART)
MF
1
TO OUTDOOR
UNIT