Warnings And Precautions; Installation Instructions; Water Inlet - Zenith ChillMaster Installation Instructions & User Manual

Freestanding chilled water
Table of Contents

Advertisement

1. Please read all Warnings and Precautions, and Installation Instructions before installing this
appliance. Never attempt to install the appliance without reading all of the applicable instructions.
2. Plumbing and electrical connections must be made in accordance with local regulations and
relevant standards. In Australia/NZ: the relevant parts of Plumbing standard AS/NZS 3500 and
Electrical Wiring Rules AS/NZS 3000.
3. This appliance must be earthed.
4. The power cord and general power outlet must be in a safe and accessible position after installation.
5. If the power supply cord is damaged it must be replaced by a Zenith Service Provider or a qualified electrician.
6. Do not remove the cover of the appliance under any circumstances without first isolating the appliance from the
power supply.
7. This unit is designed for indoor use and must not be installed outdoors or exposed to the elements of nature.
8. This unit must not be cleaned by a water jet. This unit must not be positioned in an area that may be cleaned by a
water jet.
9. This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental
capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction
concerning use of the appliance by a person responsible for their safety. For products sold in Europe, this appliance
can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental
capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning
use of the appliance in a safe way and understand the hazards involved. Children should be supervised to ensure
that they do not play with the appliance. Cleaning and user maintenance shall not be made by children without
supervision.
10. This appliance is intended to be used in staff kitchen areas in shops, offices and other working environments;
farm houses and by clients in hotels, motels and other residential type environments; bed and breakfast type
environments; catering and similar non-retail applications.
11. The appliance must be placed in an upright position.
12. Due to the process of continuous improvement, Zenith reserves the right to change details mentioned in this
manual, without notice. Visit zenithwater.co.nz to ensure you have the latest copy of this document.
50
MIN
CONDENSER
ACCESS PANEL
300 MIN
Fig.1 Minimum clearance requirement
2
806310NZ v1.06 08.19 CW ChillMaster & EconoMaster

WARNINGS AND PRECAUTIONS

Installation instructions

WATER INLET

50
FRONT
MIN
Positioning
Allow a clear gap of at least 300 mm on the left side of the
unit, and 50 mm on the other sides of the unit, to allow air
flow through the vents (Fig.1).
The average height for the centre line of the water inlet is
535 mm, and for the waste outlet, 790 mm (Fig.2).
For ChillMaster models: finished height will vary due to
adjustable feet. Place the unit on a level floor and screw
the feet in or out as appropriate to make the unit level and
steady.
Water Supply Requirements
Connect only to cold water 10 - 38°C with a pressure range
of 150 kPa - 700 kPa. For higher-pressure installations, a
pressure-limiting valve is required. For ChillMaster models,
a 500 kPa pressure limiting valve is internal to the unit.
NOTE: No valves are supplied with the SiteMaster and
EconoMaster. All necessary valves must be supplied
separately by the installer.