Installation; Floor Mounting - Johnson & Starley JANUS 6/30 Installation, Commissioning & Servicing Instructions

Circulator water heater
Table of Contents

Advertisement

4.
4.1
PREPARATION:
Referring to Figs. 3a to 3c for component identification, Para 2.6 and Fig. 1 for minimum installation clearances
4.1.1
Remove the appliance from packaging, and retain loose components,
4.1.2
Remove and discard transit strap.
4.1.3
Remove burner and controls assembly as follows:
a.
Disconnect the igniter lead from Piezo unit.
b.
Release 4 x securing screws and remove the lower front panel
c.
Remove the thermostat retaining plug from the flow connection pocket (item 5) and remove the
thermostat phial taking care to avoid causing damage to the thermostat phial.
d.
Release the burner mounting screw and remove the Burner and Controls assembly, taking care to avoid
causing damage to the Thermostat capillary.
e.
Refitting of the Burner and Controls assembly following installation of the appliance is in reverse order,
remembering to reconnect the igniter earth lead at the lower front plate screw.
4.2

FLOOR MOUNTING:

4.1
Position the appliance on the floor, and mark the position for the floor fixing screws through the front feet.
4.2
Drill and plug the fixing points (as necessary), and secure the appliance with suitable screws (not provided).
Upper front plate

INSTALLATION

Circulator/Body
fixing screws
(both sides)
Piezo unit
JANUS 6/30 General Arrangement
BURNER and CONTROLS ASSY
Fig. 3a
a
Fig. 3b
5
c
b
a
Pilot burner
b
Electrode
c
Thermocouple

Advertisement

Table of Contents
loading

Table of Contents