  • Page 1 Select-640 Timed SSDIP Contents Page Quick-fit instructions Changing pump tubes Pump tube life Safety Accuracy Electrical supply Operation – screen controls Constant pumping Rotor Adjustment Encoding Installation Problems / errors Maintenance Power Resumption Spare parts and accessories PO Box 103, Saffron Walden, CB11 3GD, UK Tel: +44 (0) 1799 551199 e-mail: info@camag.co.uk...
  • Page 2 Description The Select-640 Timed SSDIP is a dosing pump designed to give an initial dose of product, and then give subsequent doses of either the same or a different dosed at timed intervals. The size of the initial dose, the size of the timed dosages and the timed interval (in minutes) are all selected from the on- screen controls.
  • Page 3 “Adjust %”. Electrical Supply The Select-640 SSDIP doser uses a 12V DC power supply. This can either be supplied from a 12V battery or via a transformer power supply from the mains electricity supply. A 5A maximum current power supply is recommended. The Select-640 SSDIP doser normally runs below 2A although starting currents are larger and dependant on the pumping conditions encountered.
  • Page 4 It can also be used if a particular product needs to be dosed quickly within a given period. The following pumping rates will be achieved when the Select-640 SSDIP doser is set to “prime”:...
  • Page 5 36 litres / hour Brown 4.92 litres / hour It is not recommended to use the Select-640 SSDIP doser for more than 2 hours at a time in the priming mode, as tube and motor life will be reduced. Rotor Adjustment The rotors in the Select-640 SSDIP pump-head are not adjustable.
  • Page 6 Split tube  Each 6 Months After disconnecting from electric supply, remove cover from Select-640 SSDIP doser and inspect interior of pump enclosure. Ensure no ingress of moisture or other contaminant. In case of difficulty, contact your supplier. Spare Parts and Accessories...